메뉴 건너뛰기




Volumn 52, Issue 5, 2004, Pages 1016-1020

Phantom design method for high-field MRI human systems

Author keywords

High field MRI; MRI; Phantom design; RF coil; RF field

Indexed keywords

BEHAVIORAL RESEARCH; DESIGN; MAGNETIC RESONANCE IMAGING;

EID: 7544226842     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20245     Document Type: Article
Times cited : (31)

References (27)
  • 2
    • 0031083548 scopus 로고    scopus 로고
    • The intrinsic signal to noise ratio in human cardiac imaging at 1.5, 3, and 4 T
    • Hen H, Denison TJ, Singerman RW, Balaban RS. The intrinsic signal to noise ratio in human cardiac imaging at 1.5, 3, and 4 T. J Magn Reson 1997;125:65-71.
    • (1997) J Magn Reson , vol.125 , pp. 65-71
    • Hen, H.1    Denison, T.J.2    Singerman, R.W.3    Balaban, R.S.4
  • 5
    • 0033038451 scopus 로고    scopus 로고
    • High spatial resolution functional magnetic resonance imaging at very-high-magnetic field
    • Chen W, Ugurbil K, High spatial resolution functional magnetic resonance imaging at very-high-magnetic field. Top Magn Reson Imaging 1999;10:63-78.
    • (1999) Top Magn Reson Imaging , vol.10 , pp. 63-78
    • Chen, W.1    Ugurbil, K.2
  • 6
    • 0033945956 scopus 로고    scopus 로고
    • Sensitivity and power deposition in a high-field imaging experiment
    • Hoult DI, Phil D. Sensitivity and power deposition in a high-field imaging experiment. J Magn Reson Imaging 2000;12:46-67.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 46-67
    • Hoult, D.I.1    Phil, D.2
  • 9
    • 0033810130 scopus 로고    scopus 로고
    • Ultra high resolution imaging of the human head at 8 tesla: 2K x 2K for Y2K
    • Robitaille PM, Abduljalil AM, Kangarlu A. Ultra high resolution imaging of the human head at 8 tesla: 2K x 2K for Y2K. J Comput Assist Tomogr 2000;24:2-8.
    • (2000) J Comput Assist Tomogr , vol.24 , pp. 2-8
    • Robitaille, P.M.1    Abduljalil, A.M.2    Kangarlu, A.3
  • 10
    • 0035088728 scopus 로고    scopus 로고
    • Signal-to-noise ratio and absorbed power as functions of main magnetic field strength, and definition of "90°" RF pulse for the head in the birdcage coil
    • Collins CM, Smith MB. Signal-to-noise ratio and absorbed power as functions of main magnetic field strength, and definition of "90°" RF pulse for the head in the birdcage coil. Magn Reson Med 2001;45:684-691.
    • (2001) Magn Reson Med , vol.45 , pp. 684-691
    • Collins, C.M.1    Smith, M.B.2
  • 13
    • 0026567364 scopus 로고
    • Reduction of RF penetration effects in high field imaging
    • Foo TK, Hayes C, Kang YW. Reduction of RF penetration effects in high field imaging. Magn Reson Med 1992;23:287-301.
    • (1992) Magn Reson Med , vol.23 , pp. 287-301
    • Foo, T.K.1    Hayes, C.2    Kang, Y.W.3
  • 14
    • 4243556316 scopus 로고
    • Standing waves in uniform water phantoms
    • Tofts PS. Standing waves in uniform water phantoms. J Magn Reson Ser B 1994;104:134-147.
    • (1994) J Magn Reson Ser B , vol.104 , pp. 134-147
    • Tofts, P.S.1
  • 15
    • 0031865774 scopus 로고    scopus 로고
    • A spiral volume coil for improved RF field homogeneity at high static magnetic field strength
    • Alsop DC, Connick TJ, Mizsei G. A spiral volume coil for improved RF field homogeneity at high static magnetic field strength. Magn Reson Med 1998;40:49-54.
    • (1998) Magn Reson Med , vol.40 , pp. 49-54
    • Alsop, D.C.1    Connick, T.J.2    Mizsei, G.3
  • 16
    • 0030709486 scopus 로고    scopus 로고
    • On the SAR and field inhomogeneity of birdcage coils loaded with the human head
    • Jin J, Chen J. On the SAR and field inhomogeneity of birdcage coils loaded with the human head. Magn Reson Med 1997; 38:953-63.
    • (1997) Magn Reson Med , vol.38 , pp. 953-963
    • Jin, J.1    Chen, J.2
  • 22
    • 0023103498 scopus 로고
    • Simulated biological materials for electromagnetic radiation absorption studies
    • Hartsgrove G, Kraszewski A, Suroweic A. Simulated biological materials for electromagnetic radiation absorption studies. Bioelectromagnetics 1987;8:29-36.
    • (1987) Bioelectromagnetics , vol.8 , pp. 29-36
    • Hartsgrove, G.1    Kraszewski, A.2    Suroweic, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.