메뉴 건너뛰기




Volumn 39, Issue 1, 2010, Pages 11-16

Comparison of ultrasonography with submentovertex films and computed tomography scan in the diagnosis of zygomatic arch fractures

Author keywords

Fracture; Submentovertex; Ultrasonography; Zygomatic arch

Indexed keywords

ADULT; ARTICLE; COMPARATIVE STUDY; ECHOGRAPHY; EVALUATION; FEMALE; HUMAN; MALE; RADIOGRAPHY; SENSITIVITY AND SPECIFICITY; ZYGOMA ARCH FRACTURE;

EID: 75149171386     PISSN: 0250832X     EISSN: None     Source Type: Journal    
DOI: 10.1259/dmfr/97056817     Document Type: Article
Times cited : (27)

References (13)
  • 1
  • 2
    • 0024834388 scopus 로고
    • The zygomatic arch as a guide to reconstruction of comminuted malar fractures
    • Stanley JR. The zygomatic arch as a guide to reconstruction of comminuted malar fractures. Arch Otolaryngol Head Neck Surg 1989; 115: 1459-1462.
    • (1989) Arch Otolaryngol Head Neck Surg , vol.115 , pp. 1459-1462
    • Stanley, J.R.1
  • 3
    • 0033785398 scopus 로고    scopus 로고
    • Assessment of zygomatico-orbital complex fractures using ultrasonography
    • McCann PJ, Brocklebank LM, Ayoub AF. Assessment of zygomatico-orbital complex fractures using ultrasonography. Br J Oral Maxillofac Surg 2000; 38: 525-529.
    • (2000) Br J Oral Maxillofac Surg , vol.38 , pp. 525-529
    • McCann, P.J.1    Brocklebank, L.M.2    Ayoub, A.F.3
  • 4
    • 0015414282 scopus 로고
    • Reliability of ocular and orbital diagnosis with B-scan ultrasound
    • Coleman DJ. Reliability of ocular and orbital diagnosis with B-scan ultrasound. Am J Ophthalmol 1972; 74: 704-710.
    • (1972) Am J Ophthalmol , vol.74 , pp. 704-710
    • Coleman, D.J.1
  • 6
    • 0025035678 scopus 로고
    • Ultrasonographic evaluation during reduction of zygomatic arch fractures
    • Akizuki H, Michi K. Ultrasonographic evaluation during reduction of zygomatic arch fractures. J Cranio-Maxillofac Surg 1990; 118: 263-266.
    • (1990) J Cranio-Maxillofac Surg , vol.118 , pp. 263-266
    • Akizuki, H.1    Michi, K.2
  • 8
    • 1542780644 scopus 로고    scopus 로고
    • Potentials of ultrasound in the diagnosis of midfacial fractures
    • Friedrich RE, Heiland M, Bartel-Friedrich S. Potentials of ultrasound in the diagnosis of midfacial fractures. Clin Oral Invest 2003; 7: 226-229.
    • (2003) Clin Oral Invest , vol.7 , pp. 226-229
    • Friedrich, R.E.1    Heiland, M.2    Bartel-Friedrich, S.3
  • 9
    • 0342822422 scopus 로고
    • Fractures of zygomatic complex and orbit
    • Williams JLl ed, Edinburgh: Churchill Livingstone
    • Williams JLl. Fractures of zygomatic complex and orbit. In Williams JLl (ed.) Rowe and Williams' maxillofacial injuries. Edinburgh: Churchill Livingstone, 1994, pp 475-582.
    • (1994) Rowe and Williams' maxillofacial injuries , pp. 475-582
    • Williams, J.L.1
  • 12
    • 31544449111 scopus 로고    scopus 로고
    • The role of intraoperative ultrasonography in zygomatic complex fracture repair
    • Gulicher D, Krimmel M, Reiner S. The role of intraoperative ultrasonography in zygomatic complex fracture repair. Int J Oral Maxillofac Surg 2006; 35: 224-239.
    • (2006) Int J Oral Maxillofac Surg , vol.35 , pp. 224-239
    • Gulicher, D.1    Krimmel, M.2    Reiner, S.3
  • 13
    • 0023546719 scopus 로고
    • The diagnostic limitations of ultrasonography in maxillofacial surgery
    • Piette E, Lenoir JL, Reychler H. The diagnostic limitations of ultrasonography in maxillofacial surgery. J Cranio Maxillofac Surg 1987; 15: 297-305.
    • (1987) J Cranio Maxillofac Surg , vol.15 , pp. 297-305
    • Piette, E.1    Lenoir, J.L.2    Reychler, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.