-
1
-
-
5044221036
-
Mattress double anchor footprint repair: A novel, arthroscopic rotator cuff repair technique
-
Millett P.J., Mazzocca A., and Guanche C.A. Mattress double anchor footprint repair: A novel, arthroscopic rotator cuff repair technique. Arthroscopy 20 (2004) 875-879
-
(2004)
Arthroscopy
, vol.20
, pp. 875-879
-
-
Millett, P.J.1
Mazzocca, A.2
Guanche, C.A.3
-
2
-
-
34447568149
-
Part I: Footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique
-
Park M.C., ElAttrache N.S., Tibone J.E., Ahmad C.S., Jun B.J., and Lee T.Q. Part I: Footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique. J Shoulder Elbow Surg 16 (2007) 461-468
-
(2007)
J Shoulder Elbow Surg
, vol.16
, pp. 461-468
-
-
Park, M.C.1
ElAttrache, N.S.2
Tibone, J.E.3
Ahmad, C.S.4
Jun, B.J.5
Lee, T.Q.6
-
3
-
-
34250661991
-
Part II: Biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique
-
Park M.C., Tibone J.E., ElAttrache N.S., Ahmad C.S., Jun B.J., and Lee T.Q. Part II: Biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique. J Shoulder Elbow Surg 16 (2007) 469-476
-
(2007)
J Shoulder Elbow Surg
, vol.16
, pp. 469-476
-
-
Park, M.C.1
Tibone, J.E.2
ElAttrache, N.S.3
Ahmad, C.S.4
Jun, B.J.5
Lee, T.Q.6
-
4
-
-
0035166494
-
Complications of metallic suture anchors in shoulder surgery: A report of 8 cases
-
Kaar T.K., Scheneck Jr. R.C., Wirth M.A., and Rockwood Jr. C.A. Complications of metallic suture anchors in shoulder surgery: A report of 8 cases. Arthroscopy 17 (2001) 31-37
-
(2001)
Arthroscopy
, vol.17
, pp. 31-37
-
-
Kaar, T.K.1
Scheneck Jr., R.C.2
Wirth, M.A.3
Rockwood Jr., C.A.4
-
5
-
-
33751184904
-
Distant migration of a bioabsorbable implant in the shoulder
-
Weber S.C., and Kauffman J.L. Distant migration of a bioabsorbable implant in the shoulder. J Shoulder Elbow Surg 15 (2006) e48-e53
-
(2006)
J Shoulder Elbow Surg
, vol.15
-
-
Weber, S.C.1
Kauffman, J.L.2
-
6
-
-
0021365109
-
Complications about the glenohumeral joint related to the use of screws and staples
-
Zuckerman J.D., and Matsen III F.A. Complications about the glenohumeral joint related to the use of screws and staples. J Bone Joint Surg Am 66 (1984) 175-180
-
(1984)
J Bone Joint Surg Am
, vol.66
, pp. 175-180
-
-
Zuckerman, J.D.1
Matsen III, F.A.2
-
7
-
-
33744506109
-
Broken or dislodged poly-L-lactic acid bioabsorbable tacks in patients after SLAP lesion surgery
-
Sassmannshausen G., Sukay M., and Mair S.D. Broken or dislodged poly-L-lactic acid bioabsorbable tacks in patients after SLAP lesion surgery. Arthroscopy 22 (2006) 615-619
-
(2006)
Arthroscopy
, vol.22
, pp. 615-619
-
-
Sassmannshausen, G.1
Sukay, M.2
Mair, S.D.3
-
8
-
-
33846632741
-
Complications after arthroscopic rotator cuff repair
-
Brislin K.J., Field L.D., and Savoie F.H. Complications after arthroscopic rotator cuff repair. Arthroscopy 23 (2007) 124-128
-
(2007)
Arthroscopy
, vol.23
, pp. 124-128
-
-
Brislin, K.J.1
Field, L.D.2
Savoie, F.H.3
-
9
-
-
29844436781
-
Suture anchors and tacks for shoulder surgery, part II: The prevention and treatment of complications
-
Park H.B., Keyurapan E., Gill H.S., Selhi H.S., and McFarland E.G. Suture anchors and tacks for shoulder surgery, part II: The prevention and treatment of complications. Am J Sports Med 34 (2006) 136-144
-
(2006)
Am J Sports Med
, vol.34
, pp. 136-144
-
-
Park, H.B.1
Keyurapan, E.2
Gill, H.S.3
Selhi, H.S.4
McFarland, E.G.5
|