메뉴 건너뛰기




Volumn 17, Issue 1, 2009, Pages 13-18

Support vector machine for fault detection in transmission line

Author keywords

Digital fault recorder; Fault detection; Support vector machine; Transmission line protection

Indexed keywords

DIGITAL FAULT RECORDER; FAULT CURRENTS; FAULT DISTANCE; FAULT INCEPTION ANGLES; FAULT RESISTANCES; HALF CYCLE; LINE CURRENTS; MATLAB-SIMULINK; NEW APPROACHES; POWER TRANSMISSION LINES; RADIAL BASIS FUNCTIONS; REAL-TIME DATA; SUPPORT VECTOR MACHINE TECHNIQUES; TRANSMISSION LINE; TRANSMISSION LINE PROTECTION;

EID: 75149141756     PISSN: 14728915     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (9)

References (17)
  • 1
    • 0035089122 scopus 로고    scopus 로고
    • A real time hardware fault detector using an artificial neural network for distance protection, 16(1)
    • Ramachandran Venkatesan, Balasubramanian Balamurugan: A real time hardware fault detector using an artificial neural network for distance protection, 16(1), IEEE Trans.on Power Delivery, 2001, 16(1), pp. 75-82.
    • (2001) IEEE Trans. on Power Delivery , vol.16 , Issue.1 , pp. 75-82
    • Venkatesan, R.1    Balamurugan, B.2
  • 2
  • 3
    • 0031698253 scopus 로고    scopus 로고
    • Artificial neural network approach to distance protection of transmission lines
    • D.V. Coury, D.C. Jorge: Artificial Neural Network approach to distance protection of transmission lines, IEEE Trans, on Power Delivery, 1998, 13(1), pp. 102-108.
    • (1998) IEEE Trans. on Power Delivery , vol.13 , Issue.1 , pp. 102-108
    • Coury, D.V.1    Jorge, D.C.2
  • 4
    • 0035095026 scopus 로고    scopus 로고
    • Application of minimal radial basis function neural network to distance protection
    • DOI 10.1109/61.905593, PII S0885897700102237
    • P.K. Dash, A.K. Pradhan and G. Panda: Application of minimal radial basis function Neural network to distance protection, IEEE Trans, on Power Delivery, 2001, 16(1), pp. 68-74. (Pubitemid 32248463)
    • (2001) IEEE Transactions on Power Delivery , vol.16 , Issue.1 , pp. 68-74
    • Dash, P.K.1    Pradhan, A.K.2    Panda, G.3
  • 5
    • 0036815505 scopus 로고    scopus 로고
    • A Novel approach using a FIRANN for fault detection and direction estimation for high voltage transmission line
    • Angel L. Orille Fenandez Nabil Khalil L. Goanaim: A Novel approach using a FIRANN for fault detection and direction estimation for high voltage transmission line, IEEE Trans.on Power Delivery, 2002, 17(3), pp. 894-900.
    • (2002) IEEE Trans. on Power Delivery , vol.17 , Issue.3 , pp. 894-900
    • Angel, L.1    Fenandez, O.2    Khalil, N.3    Goanaim, L.4
  • 6
    • 13444310903 scopus 로고    scopus 로고
    • An accurate fault classification algorithm using a minimal radial basis function neural network
    • P.K. Dash, S.R. Samantray: An accurate fault classification algorithm using a minimal radial basis function neural network, Engineering Intelligent Systems, 2004, 4, pp. 205-210.
    • (2004) Engineering Intelligent Systems , vol.4 , pp. 205-210
    • Dash, P.K.1    Samantray, S.R.2
  • 8
    • 34147111423 scopus 로고    scopus 로고
    • Transmission line boundary protection using wavelet transform and Neural network
    • Nan zhang, Mladen Kezunovic: Transmission line boundary protection using wavelet transform and Neural Network, IEEE Trans. on Power Delivery, 2007, 22(2), pp. 859-869.
    • (2007) IEEE Trans. on Power Delivery , vol.22 , Issue.2 , pp. 859-869
    • Zhang, N.1    Kezunovic, M.2
  • 10
    • 0029205401 scopus 로고
    • A Fuzzy set approach to fault type identification in digital relaying
    • A. Ferrero, S. Sangiovannai and E. Zapitelli: A Fuzzy set approach to fault type identification in digital relaying, IEEE Trans. on Power Delivery, 1995, 10(1), pp. 169-175.
    • (1995) IEEE Trans. on Power Delivery , vol.10 , Issue.1 , pp. 169-175
    • Ferrero, A.1    Sangiovannai, S.2    Zapitelli, E.3
  • 11
    • 17844386093 scopus 로고    scopus 로고
    • Fuzzy-logic-based fault classification scheme for digital distance protection
    • Biswarup Das, J. Vittal Reddy: Fuzzy-logic-based fault classification scheme for Digital Distance Protection, IEEE Trans. on Power Delivery, 2005, 20(2), pp. 609-616.
    • (2005) IEEE Trans. on Power Delivery , vol.20 , Issue.2 , pp. 609-616
    • Das, B.1    Reddy, J.V.2
  • 12
    • 34147189577 scopus 로고    scopus 로고
    • Fault classification and section identification of an advanced series compensated transmission line using support vector machine
    • P.K.Dash, S.R.Samantaray, Ganapathy Panda: Fault classification and section identification of an advanced series compensated transmission line using support vector machine, IEEE Trans.on Power Delivery, 2007, 22(1), pp. 67-73.
    • (2007) IEEE Trans. on Power Delivery , vol.22 , Issue.1 , pp. 67-73
    • Dash, P.K.1    Samantaray, S.R.2    Panda, G.3
  • 13
    • 54049116246 scopus 로고    scopus 로고
    • Combined wavelet-SVM technique for fault zone detection in a series compensated transmissionline
    • Urmil B.Parikh, Biswarup Das, Rudra Prakash Maheshwari: Combined wavelet-SVM technique for fault zone detection in a series compensated transmissionline, IEEE Trans. on Power Delivery, 2008, 23(3), pp. 1789-1794.
    • (2008) IEEE Trans. on Power Delivery , vol.23 , Issue.3 , pp. 1789-1794
    • Parikh, U.B.1    Das, B.2    Maheshwari, R.P.3
  • 14
    • 35148875569 scopus 로고    scopus 로고
    • The utilization of digital fault recorders in protection system analysis on Tenaga Nasional Berhad transmission system
    • Abdullah Asuhaimi Mohd Zin, Sazali P.Abdul Karim: The utilization of Digital fault recorders in Protection System Analysis on Tenaga Nasional Berhad Transmission System, IEEE Trans.on Power Delivery, 2007, 22(3), pp. 2040-2045.
    • (2007) IEEE Trans. on Power Delivery , vol.22 , Issue.3 , pp. 2040-2045
    • Zin, A.A.M.1    Karim, S.P.A.2
  • 17
    • 62949167150 scopus 로고    scopus 로고
    • Available
    • Steve R.Gunn, SVM Toolbox, Available http://www.isis.ecs.soton.ac.uk/ resources/svminfo/.
    • SVM Toolbox
    • Gunn, S.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.