메뉴 건너뛰기




Volumn 103, Issue , 2004, Pages

Spalling in high strength concrete exposed to fire - Concerns, causes, critical parameters and cures

Author keywords

Fire performance; Fire resistance; High strength concrete; Moisture; Polypropylene fibres; Spalling

Indexed keywords

CRITICAL PARAMETER; DESIGN SOLUTIONS; ELEVATED TEMPERATURE; FIRE CONDITION; FIRE PERFORMANCE; HIGH STRENGTH CONCRETES; HIGH-STRENGTH CONCRETE; IN-BUILDINGS; POLYPROPYLENE FIBRES;

EID: 74949116390     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1061/40492(2000)180     Document Type: Conference Paper
Times cited : (31)

References (16)
  • 2
    • 0001916945 scopus 로고    scopus 로고
    • Analysis of pore pressure, thermal stress and fracture in rapidly heated concrete
    • NIST SP 919, Gaithersburg, MD
    • Bazant, Z.P. (1997). "Analysis of Pore Pressure, Thermal Stress and Fracture in Rapidly Heated Concrete", International Workshop on Fire Performance of High Strength Concrete, NIST SP 919, Gaithersburg, MD, pp. 155-164.
    • (1997) International Workshop on Fire Performance of High Strength Concrete , pp. 155-164
    • Bazant, Z.P.1
  • 3
    • 0012885138 scopus 로고    scopus 로고
    • Hydrocarbon fire resistance of high strength normal weight and light weight concrete incorporating polypropylene fibres
    • Sherbrooke, QC
    • Bilodeau, A., Malhotra, V.M., and Hoff, G.C. (1998). "Hydrocarbon Fire Resistance of High Strength Normal Weight and Light Weight Concrete Incorporating Polypropylene Fibres", International Symposium on High Performance and Reactive Powder Concrete, Sherbrooke, QC, pp. 271-296.
    • (1998) International Symposium on High Performance and Reactive Powder Concrete , pp. 271-296
    • Bilodeau, A.1    Malhotra, V.M.2    Hoff, G.C.3
  • 5
    • 74949095477 scopus 로고    scopus 로고
    • Channel tunnel fire protection measures questioned after fire on HGV wagon
    • Fire Prevention
    • Fire Prevention (1997). "Channel Tunnel Fire Protection Measures Questioned after Fire on HGV Wagon", Fire Prevention, 296.
    • (1997) Fire Prevention , vol.296
  • 6
  • 7
    • 0032311508 scopus 로고    scopus 로고
    • Performance of high strength concrete-filled steel columns exposed to fire
    • Kodur, V.K.R. (1998). "Performance of High Strength Concrete-Filled Steel Columns Exposed to Fire" Canadian Journal of Civil Engineering, 25(6), pp. 975-981.
    • (1998) Canadian Journal of Civil Engineering , vol.25 , Issue.6 , pp. 975-981
    • Kodur, V.K.R.1
  • 8
    • 74949143106 scopus 로고    scopus 로고
    • Fire performance of high strength concrete columns
    • Presented at, (SP in press), Chicago, IL
    • Kodur, V.K.R. (1999). "Fire Performance of High Strength Concrete Columns", Presented at: ACI Spring Convention (SP in press), Chicago, IL.
    • (1999) ACI Spring Convention
    • Kodur, V.K.R.1
  • 9
    • 0242679282 scopus 로고    scopus 로고
    • Fire Resistance of fibre-reinforced concrete
    • Canadian Society of Civil Engineers
    • Kodur, V.K.R. and Lie, T.T. (1997). "Fire Resistance of Fibre-Reinforced Concrete", Fibre Reinforced Concrete: Present and the Future, Canadian Society of Civil Engineers, pp. 189-213.
    • (1997) Fibre Reinforced Concrete: Present and the Future , pp. 189-213
    • Kodur, V.K.R.1    Lie, T.T.2
  • 11
    • 0042036935 scopus 로고    scopus 로고
    • Thermal properties of high strength concrete at elevated temperatures
    • ACI SP-170, Tokushima, Japan
    • Kodur, V.K.R. and Sultan M.A. (1998b). "Thermal Properties of High Strength Concrete at Elevated Temperatures", CANMET-ACI-JCI International Conference, ACI SP-170, Tokushima, Japan, pp. 467-480.
    • (1998) CANMET-ACI-JCI International Conference , pp. 467-480
    • Kodur, V.K.R.1    Sultan, M.A.2
  • 12
    • 0041535706 scopus 로고
    • Fire resistance of reinforced concrete columns: Test results
    • National Research Council of Canada, Ottawa, ON
    • Lie, T.T. and Woollerton, J.L. (1988). "Fire Resistance of Reinforced Concrete Columns: Test Results", Institute for Research in Construction Internal Report No. 569, National Research Council of Canada, Ottawa, ON, 302 pp.
    • (1988) Institute for Research in Construction Internal Report No. 569 , pp. 302
    • Lie, T.T.1    Woollerton, J.L.2
  • 14
    • 0027559487 scopus 로고
    • Spalling of high-strength silica fume concrete in fire
    • Sanjayan, G. and Stocks L.J. (1993). "Spalling of High-Strength Silica Fume Concrete in Fire", ACI Materials Journal, 90(2), pp. 170-173.
    • (1993) ACI Materials Journal , vol.90 , Issue.2 , pp. 170-173
    • Sanjayan, G.1    Stocks, L.J.2
  • 15
    • 0033101606 scopus 로고    scopus 로고
    • Chunnel fire. II: Analysis of concrete damage
    • Ulm F.J., Acker P., Levy M. (1999). "Chunnel Fire. II: Analysis of Concrete Damage", Journal of Engineering Mechanics, 125(3), pp. 283-289.
    • (1999) Journal of Engineering Mechanics , vol.125 , Issue.3 , pp. 283-289
    • Ulm, F.J.1    Acker, P.2    Levy, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.