메뉴 건너뛰기




Volumn 7, Issue 1, 2009, Pages

Transthoracic echocardiography for imaging of the different coronary artery segments: A feasibility study

Author keywords

[No Author keywords available]

Indexed keywords

ACUTE CORONARY SYNDROME; ADULT; ANGINA PECTORIS; ANGIOCARDIOGRAPHY; ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CORONARY ARTERY BLOOD FLOW; CORONARY ARTERY CIRCUMFLEX BRANCH; FEASIBILITY STUDY; FEMALE; HEART INFARCTION; HUMAN; LEFT ANTERIOR DESCENDING CORONARY ARTERY; LEFT CORONARY ARTERY; MAJOR CLINICAL STUDY; MALE; RIGHT CORONARY ARTERY; TRANSTHORACIC ECHOCARDIOGRAPHY; AGED; CORONARY BLOOD VESSEL; ECHOCARDIOGRAPHY; ECHOGRAPHY; METHODOLOGY; MIDDLE AGED; RADIOGRAPHY; REPRODUCIBILITY; STANDARD; ULTRASTRUCTURE; VALIDATION STUDY;

EID: 74849136447     PISSN: None     EISSN: 14767120     Source Type: Journal    
DOI: 10.1186/1476-7120-7-58     Document Type: Article
Times cited : (25)

References (15)
  • 1
    • 3042845364 scopus 로고    scopus 로고
    • Imaging of all three coronary arteries by artery transthoracic echocardiography. An illustrated guide
    • 10.1186/1476-7120-1-16
    • Imaging of all three coronary arteries by artery transthoracic echocardiography. An illustrated guide. M Krzanowski W Bodzo PP Dimitrow, Cardiovascular Ultrasound 2003 I 16 10.1186/1476-7120-1-16
    • (2003) Cardiovascular Ultrasound , vol.1 , pp. 16
    • Krzanowski, M.1    Bodzo, W.2    Dimitrow, P.P.3
  • 3
    • 1242297104 scopus 로고    scopus 로고
    • Transthoracic, harmonic mode, contrast enhanced color Doppler echocardiography in detection of restenosis after percutaneous coronary interventions. Prospective evaluation verified by coronary angiography
    • DOI 10.1016/j.euje.2003.10.004
    • Transthoracic, harmonic mode, contrast enhanced color Doppler echocardiography in detection of restenosis after percutaneous coronary interventions. Prospective evaluation verified by coronary angiography. M Krzanowski W Bodzo D Dudek G Heba M Rzeszutko R Niankowski J Dubiel A Szczeklik, Eur J Echocardiography 2004 5 51 64 10.1016/j.euje.2003.10.004 (Pubitemid 38219618)
    • (2004) European Journal of Echocardiography , vol.5 , Issue.1 , pp. 51-64
    • Krzanowski, M.1    Bodzon, W.2    Dudek, D.3    Heba, G.4    Rzeszutko, M.5    Nizankowski, R.6    Dubiel, J.7    Szczeklik, A.8
  • 4
    • 0034524968 scopus 로고    scopus 로고
    • Value of transthoracic echocardiography for the detection of high-grade coronary artery stenosis: Prospective evaluation in 50 consecutive patients scheduled for coronary angiography
    • 10.1067/mje.2000.108130. 11119277
    • Value of transthoracic echocardiography for the detection of high-grade coronary artery stenosis: prospective evaluation in 50 consecutive patients scheduled for coronary angiography. M Krzanowski W Bodzo T Brzostek R Niankowski A Szczeklik, J Am Soc Echocardiogr 2000 13 1091 9 10.1067/mje.2000.108130 11119277
    • (2000) J Am Soc Echocardiogr , vol.13 , pp. 1091-9
    • Krzanowski, M.1    Bodzo, W.2    Brzostek, T.3    Niankowski, R.4    Szczeklik, A.5
  • 5
    • 36649036790 scopus 로고    scopus 로고
    • Direct visualisation of a significant stenosis of the right coronary artery by transthoracic echocardiography. A case report
    • 10.1186/1476-7120-5-33. 17908328
    • Direct visualisation of a significant stenosis of the right coronary artery by transthoracic echocardiography. A case report. E Holte J Vegsundvåg R Wiseth, Cardiovascular Ultrasound 2007 5 33 10.1186/1476-7120-5-33 17908328
    • (2007) Cardiovascular Ultrasound , vol.5 , pp. 33
    • Holte, E.1    Vegsundvåg, J.2    Wiseth, R.3
  • 6
    • 10744221483 scopus 로고    scopus 로고
    • Simple detection of occluded coronary artery using retrograde flow in septal branch and left anterior descending coronary artery by transthoracic Doppler echocardiography at rest
    • 10.1016/j.echo.2003.09.019. 14752483
    • Simple detection of occluded coronary artery using retrograde flow in septal branch and left anterior descending coronary artery by transthoracic Doppler echocardiography at rest. K Hirata H Watanabe T Hozumi K Tokai R Otsuka K Fujimoto K Shimada T Muro M Yoshiyama J Yoshikawa, J Am Soc Echocardiogr 2004 17 108 13 10.1016/j.echo.2003.09.019 14752483
    • (2004) J Am Soc Echocardiogr , vol.17 , pp. 108-13
    • Hirata, K.1    Watanabe, H.2    Hozumi, T.3    Tokai, K.4    Otsuka, R.5    Fujimoto, K.6    Shimada, K.7    Muro, T.8    Yoshiyama, M.9    Yoshikawa, J.10
  • 7
    • 58449121979 scopus 로고    scopus 로고
    • Transthoracic echocardiography in the detection of chronic total coronary artery occlusion
    • 10.1093/ejechocard/jen159
    • Transthoracic echocardiography in the detection of chronic total coronary artery occlusion. AA Boshchenko AV Vrublevsky RS Karpov, Eur J Echocardiography 2009 10 62 68 10.1093/ejechocard/jen159
    • (2009) Eur J Echocardiography , vol.10 , pp. 62-68
    • Boshchenko, A.A.1    Vrublevsky, A.V.2    Karpov, R.S.3
  • 8
    • 0035499557 scopus 로고    scopus 로고
    • Noninvasive detection of total occlusion of the left anterior descending coronary artery with transthoracic Doppler echocardiography
    • 10.1016/S0735-1097(01)01556-X. 11691503
    • Noninvasive detection of total occlusion of the left anterior descending coronary artery with transthoracic Doppler echocardiography. N Watanabe T Akasaka Y Yamaura M Akiyama Y Koyama N Kamiyama Y Neishi S Kaji Y Saito K Yoshida, J Am Coll Cardiol 2001 38 1328 32 10.1016/S0735-1097(01)01556-X 11691503
    • (2001) J Am Coll Cardiol , vol.38 , pp. 1328-32
    • Watanabe, N.1    Akasaka, T.2    Yamaura, Y.3    Akiyama, M.4    Koyama, Y.5    Kamiyama, N.6    Neishi, Y.7    Kaji, S.8    Saito, Y.9    Yoshida, K.10
  • 9
    • 21344442395 scopus 로고    scopus 로고
    • A novel technique to detect total occlusion in the right coronary artery using retrograde flow by transthoracic Doppler echocardiography
    • 10.1016/j.echo.2004.11.018. 16003266
    • A novel technique to detect total occlusion in the right coronary artery using retrograde flow by transthoracic Doppler echocardiography. R Otsuka H Watanabe K Hirata K Tokai T Muro T Hozumi M Yoshiyama J Yoshikawa, J Am Soc Echocardiogr 2005 18 704 9 10.1016/j.echo.2004.11.018 16003266
    • (2005) J Am Soc Echocardiogr , vol.18 , pp. 704-9
    • Otsuka, R.1    Watanabe, H.2    Hirata, K.3    Tokai, K.4    Muro, T.5    Hozumi, T.6    Yoshiyama, M.7    Yoshikawa, J.8
  • 10
    • 0021923120 scopus 로고
    • Changes in collateral channel filling immediately after controlled coronary artery occlusion by an angioplasty balloon in human subjects
    • 3156171
    • Changes in collateral channel filling immediately after controlled coronary artery occlusion by an angioplasty balloon in human subjects. KP Rentrop M Cohen H Blanke RA Phillips, J Am Coll Cardiol 1985 5 587 92 3156171
    • (1985) J Am Coll Cardiol , vol.5 , pp. 587-92
    • Rentrop, K.P.1    Cohen, M.2    Blanke, H.3    Phillips, R.A.4
  • 11
    • 0033978923 scopus 로고    scopus 로고
    • Value of acceleration flow and the prestenotic to stenotic coronary flow velocity ratio by transthoracic color Doppler echocardiography in noninvasive diagnosis of restenosis after percutaneous transluminal coronary angioplasty
    • 10.1016/S0735-1097(99)00501-X. 10636275
    • Value of acceleration flow and the prestenotic to stenotic coronary flow velocity ratio by transthoracic color Doppler echocardiography in noninvasive diagnosis of restenosis after percutaneous transluminal coronary angioplasty. T Hozumi K Yoshida T Akasaka Y Asami Y Kanzaki Y Ueda A Yamamuro T Takagi J Yoshikawa, J Am Coll Cardiol 2000 35 164 8 10.1016/S0735-1097(99)00501-X 10636275
    • (2000) J Am Coll Cardiol , vol.35 , pp. 164-8
    • Hozumi, T.1    Yoshida, K.2    Akasaka, T.3    Asami, Y.4    Kanzaki, Y.5    Ueda, Y.6    Yamamuro, A.7    Takagi, T.8    Yoshikawa, J.9
  • 12
    • 0033746494 scopus 로고    scopus 로고
    • Technical achievement: Transthoracic doppler echocardiography can be used to detect LAD restenosis after coronary angioplasty
    • DOI 10.1046/j.1365-2281.2000.00266.x
    • Technical achievement: transthoracic Doppler echocardiography can be used to detect LAD restenosis after coronary angioplasty. M Saraste JW Koskenvuo J Mikkola L Pelttari JO Toikka JJ Hartiala, Clin Physiol 2000 6 428 33 10.1046/j.1365-2281.2000.00266.x (Pubitemid 30814577)
    • (2000) Clinical Physiology , vol.20 , Issue.6 , pp. 428-433
    • Saraste, M.1    Koskenvuo, J.W.2    Mikkola, J.3    Pelttari, L.4    Toikka, J.O.5    Hartiala, J.J.6
  • 15
    • 67651087430 scopus 로고    scopus 로고
    • Detection, location, and severity assessment of left anterior descending coronary artery stenoses by means of contrast-enhanced transthoracic harmonic echo Doppler
    • 10.1093/eurheartj/ehp163. 19429916
    • Detection, location, and severity assessment of left anterior descending coronary artery stenoses by means of contrast-enhanced transthoracic harmonic echo Doppler. C Caiati N Zedda M Cadeddu L Chen C Montaldo S Iliceto ME Lepera S Favale, Eur Heart J 2009 30 1797 806 10.1093/eurheartj/ehp163 19429916
    • (2009) Eur Heart J , vol.30 , pp. 1797-806
    • Caiati, C.1    Zedda, N.2    Cadeddu, M.3    Chen, L.4    Montaldo, C.5    Iliceto, S.6    Lepera, M.E.7    Favale, S.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.