Volumn 26, Issue 4, 2009, Pages 472-483

The assesment of acoustical and electromagnetic noise on EEG monitoring during spinal surgery operations;Spinal cerrahi operasyonlarinda EEG monitörlemesini etkileyen i̇şitsel ve elektromanyetik gürültünün i̇rdelenmesi

Author keywords

Acoustical noise; Anesthesia; EEG; Electromagnetic noise; Operation room

Indexed keywords

ARTICLE; BRAIN FUNCTION; CAUTERIZATION; DEVICE; ELECTROENCEPHALOGRAM; ELECTROMAGNETIC FIELD; ELECTROPHYSIOLOGY; MEDICAL ASSESSMENT; MONITORING; OSCILLATION; SPINE SURGERY;

EID: 74749103813     PISSN: 13001817     EISSN: 13021664     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (1)

References (25)
  • 4
    • 0030901893 scopus 로고    scopus 로고
    • Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers
    • Glass PSA, Bloom M, Kearse L, Rosow C, Sebel P, Manberg P. Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers. Anesthesiology 1997; 86:836-47
    • (1997) Anesthesiology , vol.86 , pp. 836-847
    • Glass, P.S.A.1    Bloom, M.2    Kearse, L.3    Rosow, C.4    Sebel, P.5    Manberg, P.6
  • 6
    • 74749097236 scopus 로고    scopus 로고
    • Gürültü Kontrol Yönetmeliǧi. Resmi Gazete. Tarihi: 11/12/1986, R.G. Sayisi: 19308
    • Gürültü Kontrol Yönetmeliǧi. Resmi Gazete. Tarihi: 11/12/1986, R.G. Sayisi: 19308
  • 8
    • 34247877747 scopus 로고    scopus 로고
    • Noise in the operating rooms of Johns Hopkins Hospital
    • Kracht JM, Busch-Vishniac IJ, West JE. Noise in the operating rooms of Johns Hopkins Hospital. Acoust Soc Am. 2007;121:2673-80
    • (2007) Acoust Soc Am , vol.121 , pp. 2673-2680
    • Kracht, J.M.1    Busch-Vishniac, I.J.2    West, J.E.3
  • 11
    • 0008662828 scopus 로고    scopus 로고
    • National Institute for Occupational Safety and Health, Cincinnatii OH: National Institute for Occupational Safety and Health;
    • National Institute for Occupational Safety and Health. Occupational noise exposure. Revised criteria. Cincinnatii OH: National Institute for Occupational Safety and Health; 1998
    • (1998) Occupational noise exposure. Revised criteria
  • 13
    • 45149092883 scopus 로고    scopus 로고
    • Evaluation and Measurement of Magnetic Field Exposure at a Typical High Voltage Substation and Its Power Lines
    • Özen S. Evaluation and Measurement of Magnetic Field Exposure at a Typical High Voltage Substation and Its Power Lines, Radiation Protection Dosimetry 2008; 128: 198-205
    • (2008) Radiation Protection Dosimetry , vol.128 , pp. 198-205
    • Özen, S.1
  • 14
    • 74749090183 scopus 로고    scopus 로고
    • Recording neuroelectrical activity under hostile surgical environment
    • Özgoren M. Recording neuroelectrical activity under hostile surgical environment. Int. J. Psychophysiol 2008; 69: 160
    • (2008) Int. J. Psychophysiol , vol.69 , pp. 160
    • Özgoren, M.1
  • 16
    • 0020678303 scopus 로고    scopus 로고
    • Rampil IJ, Holzer JA, Quest DO, Rosenbaum SH, Correll JW: Prognostic value of computerized EEG analysis during carotid endarterectomy. Anesth Analg 1983; 62:186-92,
    • Rampil IJ, Holzer JA, Quest DO, Rosenbaum SH, Correll JW: Prognostic value of computerized EEG analysis during carotid endarterectomy. Anesth Analg 1983; 62:186-92,
  • 20
    • 0019820832 scopus 로고    scopus 로고
    • Sundt TM, Sharbrough FW, Piepgras DG, Kearns TP, Messick JM, O\'Fallon WM. Correlation of cerebral blood flow and electroencephalographic changes during carotid endarterectomy with results of surgery and hemodynamics of cerebral ischemia. Mayo Clin Proc 1981; 56:533-43
    • Sundt TM, Sharbrough FW, Piepgras DG, Kearns TP, Messick JM, O\'Fallon WM. Correlation of cerebral blood flow and electroencephalographic changes during carotid endarterectomy with results of surgery and hemodynamics of cerebral ischemia. Mayo Clin Proc 1981; 56:533-43
  • 21
    • 4344574647 scopus 로고    scopus 로고
    • Fundamentals Of EEG Measurement
    • Teplan M. Fundamentals Of EEG Measurement. Measurement Science Review 2002;2;1-11
    • (2002) Measurement Science Review , vol.2 , pp. 1-11
    • Teplan, M.1
  • 22
    • 0026571325 scopus 로고
    • A comfortable hypothesis reevaluated. Cerebral metabolic depressionand brain protection during ischemia
    • Todd MM, Warner DS. A comfortable hypothesis reevaluated. Cerebral metabolic depressionand brain protection during ischemia Anesthesiology 1992; 76: 161-4.
    • (1992) Anesthesiology , vol.76 , pp. 161-164
    • Todd, M.M.1    Warner, D.S.2
  • 23
    • 0022634578 scopus 로고
    • 50 Hz electromagnetic environment and incidence of childhood tumors in Stockholm Country
    • Tomenius L. 50 Hz electromagnetic environment and incidence of childhood tumors in Stockholm Country. Bioelectromagnetics 1986; 7: 191-207.
    • (1986) Bioelectromagnetics , vol.7 , pp. 191-207
    • Tomenius, L.1
  • 24


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.