1
-
-
0027370108
-
The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus
-
Diabetes Control and Complications Trial Research Group
-
Diabetes Control and Complications Trial Research Group. The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med. 329 (1993) 977-986
-
(1993)
N Engl J Med.
, vol.329
, pp. 977-986
-
-
-
2
-
-
0032511583
-
Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33) [published correction appears in Lancet. 1999;354:602]
-
UK Prospective Diabetes Study (UKPDS) Group
-
UK Prospective Diabetes Study (UKPDS) Group. Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33) [published correction appears in Lancet. 1999;354:602]. Lancet. 352 (1998) 837-853
-
(1998)
Lancet.
, vol.352
, pp. 837-853
-
-
-
3
-
-
0029147687
-
Intensive insulin therapy prevents the progression of diabetic microvascular complications in Japanese patients with non-insulindependent diabetes mellitus: A randomized prospective 6-year study
-
Ohkubo Y., Kishikawa H., Araki E., et al. Intensive insulin therapy prevents the progression of diabetic microvascular complications in Japanese patients with non-insulindependent diabetes mellitus: A randomized prospective 6-year study. Diabetes Res Clin Pract. 28 (1995) 103-117
-
(1995)
Diabetes Res Clin Pract.
, vol.28
, pp. 103-117
-
-
Ohkubo, Y.1
Kishikawa, H.2
Araki, E.3
-
4
-
-
0034071036
-
Long-term results of the Kumamoto Study on optimal diabetes control in type 2 diabetic patients
-
Shichiri M., Kishikawa H., Ohkubo Y., and Wake N. Long-term results of the Kumamoto Study on optimal diabetes control in type 2 diabetic patients. Diabetes Care. 23 Suppl 2 (2000) B21-B29
-
(2000)
Diabetes Care.
, vol.23
, Issue.SUPPL. 2
-
-
Shichiri, M.1
Kishikawa, H.2
Ohkubo, Y.3
Wake, N.4
-
5
-
-
33644961570
-
FlexPen: Addressing issues of confidence and convenience in insulin delivery
-
Korytkowski M., Niskanen L., and Asakura T. FlexPen: Addressing issues of confidence and convenience in insulin delivery. Clin Ther. 27 Suppl B (2005) S89-S100
-
(2005)
Clin Ther.
, vol.27
, Issue.SUPPL. B
-
-
Korytkowski, M.1
Niskanen, L.2
Asakura, T.3
-
6
-
-
0031827947
-
Comparison of NovoPen 3 and syringes/vials in the acceptance of insulin therapy in NIDDM patients with secondary failure to oral hypoglycaemic agents
-
Kadiri A., Chraibi A., Marouan F., et al. Comparison of NovoPen 3 and syringes/vials in the acceptance of insulin therapy in NIDDM patients with secondary failure to oral hypoglycaemic agents. Diabetes Res Clin Pract. 41 (1998) 15-23
-
(1998)
Diabetes Res Clin Pract.
, vol.41
, pp. 15-23
-
-
Kadiri, A.1
Chraibi, A.2
Marouan, F.3
-
7
-
-
33751566656
-
Medication adherence and the associated health-economic impact among patients with type 2 diabetes mellitus converting to insulin pen therapy: An analysis of third-party managed care claims data [published correction appears in Clin Ther. 2006;28:1968-1969]
-
Lee W.C., Balu S., Cobden D., et al. Medication adherence and the associated health-economic impact among patients with type 2 diabetes mellitus converting to insulin pen therapy: An analysis of third-party managed care claims data [published correction appears in Clin Ther. 2006;28:1968-1969]. Clin Ther. 28 (2006) 1712-1725
-
(2006)
Clin Ther.
, vol.28
, pp. 1712-1725
-
-
Lee, W.C.1
Balu, S.2
Cobden, D.3
-
8
-
-
29944440154
-
Comparison of the dosing accuracy of two insulin injection devices
-
Asakura T. Comparison of the dosing accuracy of two insulin injection devices. J Clin Res. 8 (2005) 33-40
-
(2005)
J Clin Res.
, vol.8
, pp. 33-40
-
-
Asakura, T.1
-
10
-
-
50149101079
-
Differences in the dose accuracy of insulin pens
-
Hanel H., Weise A., Sun W., et al. Differences in the dose accuracy of insulin pens. J Diabetes Sci Technol. 2 (2008) 478-481
-
(2008)
J Diabetes Sci Technol.
, vol.2
, pp. 478-481
-
-
Hanel, H.1
Weise, A.2
Sun, W.3
-
11
-
-
70349306725
-
A comparison of injection force and dosage scale size between NovoPen 3 and NovoPen 4
-
Donsmark M., Herold L., and Kristensen C.M. A comparison of injection force and dosage scale size between NovoPen 3 and NovoPen 4. Diabetes Technol Ther. 11 (2009) 581-585
-
(2009)
Diabetes Technol Ther.
, vol.11
, pp. 581-585
-
-
Donsmark, M.1
Herold, L.2
Kristensen, C.M.3
-
12
-
-
74549164324
-
Pen-injectors for medical use-Part 1: Pen-injectors-requirements and test methods
-
DS/EN ISO 11608-1
-
DS/EN ISO 11608-1. Pen-injectors for medical use-Part 1: Pen-injectors-requirements and test methods. Charlottenlund, Denmark: Dansk Standard (2001)
-
(2001)
Charlottenlund, Denmark: Dansk Standard
-
-
-
13
-
-
74549159778
-
-
® 4 Accessed November 11, 2009.
-
® 4. http://www.novonordisk.com/diabetes/hcp/injectiondevices/novopen4/default.aspx Accessed November 11, 2009.
-
-
-
-
14
-
-
0036740312
-
Accuracy and precision of the NovoPen 3 insulin delivery device after mechanical and temperature stresses
-
Santiago O.M., Khutoryansky N.M., Bilbo C.M., et al. Accuracy and precision of the NovoPen 3 insulin delivery device after mechanical and temperature stresses. Endocr Pract. 8 (2002) 351-355
-
(2002)
Endocr Pract.
, vol.8
, pp. 351-355
-
-
Santiago, O.M.1
Khutoryansky, N.M.2
Bilbo, C.M.3
-
15
-
-
33748687796
-
Dose accuracy of a reusable insulin pen using a cartridge system with an integrated plunger mechanism
-
Clarke A., and Dain M.P. Dose accuracy of a reusable insulin pen using a cartridge system with an integrated plunger mechanism. Expert Opin Drug Deliv. 3 (2006) 677-683
-
(2006)
Expert Opin Drug Deliv.
, vol.3
, pp. 677-683
-
-
Clarke, A.1
Dain, M.P.2
|