-
3
-
-
25144499966
-
The importance of urethral visualization for preplanned permanent prostate implants
-
Sloboda R., and Pedersen J. The importance of urethral visualization for preplanned permanent prostate implants. Brachytherapy 4 (1995) 195-201
-
(1995)
Brachytherapy
, vol.4
, pp. 195-201
-
-
Sloboda, R.1
Pedersen, J.2
-
4
-
-
34047126239
-
Tumour and target volumes in permanent prostate brachytherapy: a supplement to the ESTRO/EAU/EORTC recommendations on prostate brachytherapy
-
Salembier C., Lavagnini P., Nickers P., et al. Tumour and target volumes in permanent prostate brachytherapy: a supplement to the ESTRO/EAU/EORTC recommendations on prostate brachytherapy. Radiother Oncol 83 (2007) 3-10
-
(2007)
Radiother Oncol
, vol.83
, pp. 3-10
-
-
Salembier, C.1
Lavagnini, P.2
Nickers, P.3
-
5
-
-
0029008161
-
Dosimetry guidelines to minimize urethral and rectal morbidity following transperineal I-125 prostate brachytherapy
-
Wallner K., Roy J., and Harrison M. Dosimetry guidelines to minimize urethral and rectal morbidity following transperineal I-125 prostate brachytherapy. Int J Radiat Oncol Biol Phys 32 (1995) 465-471
-
(1995)
Int J Radiat Oncol Biol Phys
, vol.32
, pp. 465-471
-
-
Wallner, K.1
Roy, J.2
Harrison, M.3
-
6
-
-
0036471789
-
The dosimetry of prostate brachytherapy-induced urethral strictures
-
Merrick G., Butler W., Tollenaar B., et al. The dosimetry of prostate brachytherapy-induced urethral strictures. Int J Radiat Oncol Biol Phys 52 (2002) 461-468
-
(2002)
Int J Radiat Oncol Biol Phys
, vol.52
, pp. 461-468
-
-
Merrick, G.1
Butler, W.2
Tollenaar, B.3
-
7
-
-
1142304255
-
Update of AAPM Task Group No. 43 Report: a revised AAPM protocol for brachytherapy dose calculations
-
Rivard M.J., Coursey B.M., DeWerd L.A., et al. Update of AAPM Task Group No. 43 Report: a revised AAPM protocol for brachytherapy dose calculations. Med Phys 31 (2004) 633-674
-
(2004)
Med Phys
, vol.31
, pp. 633-674
-
-
Rivard, M.J.1
Coursey, B.M.2
DeWerd, L.A.3
-
8
-
-
0032518595
-
A conformal index (COIN) to evaluate implant quality and dose specification in brachytherapy
-
Baltas D., Kolotas C., Geramani K., et al. A conformal index (COIN) to evaluate implant quality and dose specification in brachytherapy. Int J Radiat Oncol Biol Phys 40 (1998) 515-524
-
(1998)
Int J Radiat Oncol Biol Phys
, vol.40
, pp. 515-524
-
-
Baltas, D.1
Kolotas, C.2
Geramani, K.3
-
9
-
-
74549114606
-
-
ICRU Report No. 50. Prescribing, recording and reporting photon beam therapy; 1993.
-
ICRU Report No. 50. Prescribing, recording and reporting photon beam therapy; 1993.
-
-
-
-
10
-
-
0004179507
-
-
No. 62. A supplement to ICRU 50;
-
ICRU Report No. 62. A supplement to ICRU 50; 1999.
-
(1999)
ICRU Report
-
-
-
11
-
-
55149090271
-
Report on the early efficacy and tolerability of I-125 permanent prostate brachytherapy from a UK multi-institutional database
-
Mitchell D., Mandall P., Bottomley D., et al. Report on the early efficacy and tolerability of I-125 permanent prostate brachytherapy from a UK multi-institutional database. Clin Oncol 20 (2008) 738-744
-
(2008)
Clin Oncol
, vol.20
, pp. 738-744
-
-
Mitchell, D.1
Mandall, P.2
Bottomley, D.3
-
12
-
-
0036603917
-
Effect of prostatic edema on CT-based postimplant dosimetry
-
Dogan N., Mohideen N., Glasgow G., et al. Effect of prostatic edema on CT-based postimplant dosimetry. Int J Radiat Oncol Biol Phys 53 (2002) 483-489
-
(2002)
Int J Radiat Oncol Biol Phys
, vol.53
, pp. 483-489
-
-
Dogan, N.1
Mohideen, N.2
Glasgow, G.3
-
13
-
-
0031059638
-
Source placement error for permanent implant of the prostate
-
Roberson P., Narayana V., McShan D., et al. Source placement error for permanent implant of the prostate. Med Phys 24 (1997) 251-257
-
(1997)
Med Phys
, vol.24
, pp. 251-257
-
-
Roberson, P.1
Narayana, V.2
McShan, D.3
-
14
-
-
0037297403
-
Pre- and post-implant dosimetry: an intercomparison between UK prostate brachytherapy centres
-
Al-Qaisieh B. Pre- and post-implant dosimetry: an intercomparison between UK prostate brachytherapy centres. Radiother Oncol 66 (2003) 181-183
-
(2003)
Radiother Oncol
, vol.66
, pp. 181-183
-
-
Al-Qaisieh, B.1
-
15
-
-
0036223481
-
Impact of prostate volume evaluation by different observers on CT-based post implant dosimetry
-
Al-Qaisieh B., Ash D., Bottomley D., et al. Impact of prostate volume evaluation by different observers on CT-based post implant dosimetry. Radiother Oncol 62 (2002) 267-273
-
(2002)
Radiother Oncol
, vol.62
, pp. 267-273
-
-
Al-Qaisieh, B.1
Ash, D.2
Bottomley, D.3
-
16
-
-
45849103875
-
MRI-based preplanning in low-dose-rate prostate brachytherapy
-
Tanaka O., Hayashi S., Matsuo M., et al. MRI-based preplanning in low-dose-rate prostate brachytherapy. Radiother Oncol 88 (2008) 115-120
-
(2008)
Radiother Oncol
, vol.88
, pp. 115-120
-
-
Tanaka, O.1
Hayashi, S.2
Matsuo, M.3
-
17
-
-
33645106619
-
A simple technique for determining accurate urethral dosimetry after seed brachytherapy for prostate cancer
-
Millar J., Longano A., Imbert S., et al. A simple technique for determining accurate urethral dosimetry after seed brachytherapy for prostate cancer. Brachytherapy 5 (2006) 27-31
-
(2006)
Brachytherapy
, vol.5
, pp. 27-31
-
-
Millar, J.1
Longano, A.2
Imbert, S.3
|