메뉴 건너뛰기




Volumn 89, Issue 2, 2010, Pages 403-408

Impact of Endoscopic Versus Open Saphenous Vein Harvest Techniques on Outcomes After Coronary Artery Bypass Grafting

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ARTICLE; CONTROLLED STUDY; CORONARY ARTERY BYPASS GRAFT; ENDOSCOPIC SAPHENOUS VEIN HARVEST; FEMALE; FOLLOW UP; HEART EJECTION FRACTION; HEART INFARCTION; HOSPITALIZATION; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; MORTALITY; OPEN VAIN HARVEST; POSTOPERATIVE COMPLICATION; POSTOPERATIVE INFECTION; PRIORITY JOURNAL; SAPHENOUS VEIN GRAFT; TREATMENT OUTCOME;

EID: 74549171570     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.athoracsur.2009.09.061     Document Type: Article
Times cited : (82)

References (26)
  • 1
    • 0032126578 scopus 로고    scopus 로고
    • Endoscopic versus traditional saphenous vein harvesting: a prospective, randomized trial
    • Allen K.B., Griffith G.L., Heimansohn D.A., et al. Endoscopic versus traditional saphenous vein harvesting: a prospective, randomized trial. Ann Thorac Surg 66 (1998) 26-32
    • (1998) Ann Thorac Surg , vol.66 , pp. 26-32
    • Allen, K.B.1    Griffith, G.L.2    Heimansohn, D.A.3
  • 2
    • 0034574526 scopus 로고    scopus 로고
    • Risk factors for leg wound complications following endoscopic versus traditional saphenous vein harvesting
    • Allen K.B., Heimansohn D.A., Robison R.J., et al. Risk factors for leg wound complications following endoscopic versus traditional saphenous vein harvesting. Heart Surg Forum 3 (2000) 325-330
    • (2000) Heart Surg Forum , vol.3 , pp. 325-330
    • Allen, K.B.1    Heimansohn, D.A.2    Robison, R.J.3
  • 3
    • 0345095490 scopus 로고    scopus 로고
    • Leg wound infection after coronary artery bypass grafting: a meta-analysis comparing minimally invasive versus conventional vein harvesting
    • Athanasiou T., Aziz O., Skapinakis P., et al. Leg wound infection after coronary artery bypass grafting: a meta-analysis comparing minimally invasive versus conventional vein harvesting. Ann Thorac Surg 76 (2003) 2141-2146
    • (2003) Ann Thorac Surg , vol.76 , pp. 2141-2146
    • Athanasiou, T.1    Aziz, O.2    Skapinakis, P.3
  • 4
    • 32144433053 scopus 로고    scopus 로고
    • Minimally invasive conduit harvesting: a systematic review
    • Aziz O., Athanasiou T., and Darzi A. Minimally invasive conduit harvesting: a systematic review. Eur J Cardiothorac Surg 29 (2006) 324-333
    • (2006) Eur J Cardiothorac Surg , vol.29 , pp. 324-333
    • Aziz, O.1    Athanasiou, T.2    Darzi, A.3
  • 5
    • 0036161717 scopus 로고    scopus 로고
    • Endoscopic versus open saphenous vein harvest: a comparison of postoperative wound complications
    • Bitondo J.M., Daggett W.M., Torchiana D.F., et al. Endoscopic versus open saphenous vein harvest: a comparison of postoperative wound complications. Ann Thorac Surg 73 (2002) 523-528
    • (2002) Ann Thorac Surg , vol.73 , pp. 523-528
    • Bitondo, J.M.1    Daggett, W.M.2    Torchiana, D.F.3
  • 6
    • 2542485315 scopus 로고    scopus 로고
    • Endoscopic vein harvest: advantages and limitations
    • Bonde P., Graham A.N., and MacGowan S.W. Endoscopic vein harvest: advantages and limitations. Ann Thorac Surg 77 (2004) 2076-2082
    • (2004) Ann Thorac Surg , vol.77 , pp. 2076-2082
    • Bonde, P.1    Graham, A.N.2    MacGowan, S.W.3
  • 7
    • 0036159915 scopus 로고    scopus 로고
    • A prospective randomized trial of endoscopic versus conventional harvesting of the saphenous vein in coronary artery bypass surgery
    • Kiaii B., Moon B.C., Massel D., et al. A prospective randomized trial of endoscopic versus conventional harvesting of the saphenous vein in coronary artery bypass surgery. J Thorac Cardiovasc Surg 123 (2002) 204-212
    • (2002) J Thorac Cardiovasc Surg , vol.123 , pp. 204-212
    • Kiaii, B.1    Moon, B.C.2    Massel, D.3
  • 8
    • 0035707239 scopus 로고    scopus 로고
    • Prospective analysis of endoscopic vein harvesting
    • Patel A.N., Hebeler R.F., Hamman B.L., et al. Prospective analysis of endoscopic vein harvesting. Am J Surg 182 (2001) 716-719
    • (2001) Am J Surg , vol.182 , pp. 716-719
    • Patel, A.N.1    Hebeler, R.F.2    Hamman, B.L.3
  • 9
    • 0032746937 scopus 로고    scopus 로고
    • A randomized trial of endoscopic versus open saphenous vein harvest in coronary bypass surgery
    • Puskas J.D., Wright C.E., Miller P.K., et al. A randomized trial of endoscopic versus open saphenous vein harvest in coronary bypass surgery. Ann Thorac Surg 68 (1999) 1509-1512
    • (1999) Ann Thorac Surg , vol.68 , pp. 1509-1512
    • Puskas, J.D.1    Wright, C.E.2    Miller, P.K.3
  • 10
    • 33845886569 scopus 로고    scopus 로고
    • Endoscopic vascular harvest in coronary artery bypass grafting surgery: a consensus statement of the International Society of Minimally Invasive Cardiothoracic Surgery (ISMICS) 2005
    • Allen K.B., Cheng D., Cohn W., et al. Endoscopic vascular harvest in coronary artery bypass grafting surgery: a consensus statement of the International Society of Minimally Invasive Cardiothoracic Surgery (ISMICS) 2005. Innovat Technol Tech Cardiothorac Vasc Surg 1 (2005) 51-60
    • (2005) Innovat Technol Tech Cardiothorac Vasc Surg , vol.1 , pp. 51-60
    • Allen, K.B.1    Cheng, D.2    Cohn, W.3
  • 11
    • 85129715882 scopus 로고    scopus 로고
    • Endoscopic vascular harvest in coronary artery bypass grafting surgery: a meta-analysis of randomized trials and controlled trials
    • Cheng D., Allen K.B., Cohn W., et al. Endoscopic vascular harvest in coronary artery bypass grafting surgery: a meta-analysis of randomized trials and controlled trials. Innovat Technol Tech Cardiothorac Vasc Surg 1 (2005) 61-74
    • (2005) Innovat Technol Tech Cardiothorac Vasc Surg , vol.1 , pp. 61-74
    • Cheng, D.1    Allen, K.B.2    Cohn, W.3
  • 12
    • 14644393623 scopus 로고    scopus 로고
    • Randomized trial of endoscopic versus open vein harvest for coronary artery bypass grafting: six-month patency rates
    • Yun K.L., Wu Y., Aharonian V., et al. Randomized trial of endoscopic versus open vein harvest for coronary artery bypass grafting: six-month patency rates. J Thorac Cardiovasc Surg 129 (2005) 496-503
    • (2005) J Thorac Cardiovasc Surg , vol.129 , pp. 496-503
    • Yun, K.L.1    Wu, Y.2    Aharonian, V.3
  • 13
    • 0034088978 scopus 로고    scopus 로고
    • Endoscopic and traditional saphenous vein harvest: a histologic comparison
    • Griffith G.L., Allen K.B., Waller B.F., et al. Endoscopic and traditional saphenous vein harvest: a histologic comparison. Ann Thorac Surg 69 (2000) 520-523
    • (2000) Ann Thorac Surg , vol.69 , pp. 520-523
    • Griffith, G.L.1    Allen, K.B.2    Waller, B.F.3
  • 14
    • 67650909125 scopus 로고    scopus 로고
    • Endoscopic versus open vein-graft harvesting in coronary-artery bypass surgery
    • Lopes R.D., Hafley G.E., Allen K.B., et al. Endoscopic versus open vein-graft harvesting in coronary-artery bypass surgery. N Engl J Med 361 (2009) 235-244
    • (2009) N Engl J Med , vol.361 , pp. 235-244
    • Lopes, R.D.1    Hafley, G.E.2    Allen, K.B.3
  • 15
    • 38349136233 scopus 로고    scopus 로고
    • Coronary artery bypass graft failure after on-pump and off-pump coronary artery bypass: findings from PREVENT IV
    • Magee M.J., Alexander J.H., Hafley G., et al. Coronary artery bypass graft failure after on-pump and off-pump coronary artery bypass: findings from PREVENT IV. Ann Thorac Surg 85 (2008) 494-500
    • (2008) Ann Thorac Surg , vol.85 , pp. 494-500
    • Magee, M.J.1    Alexander, J.H.2    Hafley, G.3
  • 16
    • 57649215386 scopus 로고    scopus 로고
    • Saphenous vein conduits harvested by endoscopic technique exhibit structural and functional damage
    • Rousou L.J., Taylor K.B., Lu X.G., et al. Saphenous vein conduits harvested by endoscopic technique exhibit structural and functional damage. Ann Thorac Surg 87 (2009) 62-70
    • (2009) Ann Thorac Surg , vol.87 , pp. 62-70
    • Rousou, L.J.1    Taylor, K.B.2    Lu, X.G.3
  • 17
    • 7244245581 scopus 로고    scopus 로고
    • Are wound healing disturbances and length of hospital stay reduced with minimally invasive vein harvest?. A meta-analysis
    • Athanasiou T., Aziz O., Al-Ruzzeh S., et al. Are wound healing disturbances and length of hospital stay reduced with minimally invasive vein harvest?. A meta-analysis. Eur J Cardiothorac Surg 26 (2004) 1015-1026
    • (2004) Eur J Cardiothorac Surg , vol.26 , pp. 1015-1026
    • Athanasiou, T.1    Aziz, O.2    Al-Ruzzeh, S.3
  • 18
    • 40949155495 scopus 로고    scopus 로고
    • Is minimally invasive harvesting of the great saphenous vein for coronary artery bypass surgery a cost-effective technique?
    • Rao C., Aziz O., Deeba S., et al. Is minimally invasive harvesting of the great saphenous vein for coronary artery bypass surgery a cost-effective technique?. J Thorac Cardiovasc Surg 135 (2008) 809-815
    • (2008) J Thorac Cardiovasc Surg , vol.135 , pp. 809-815
    • Rao, C.1    Aziz, O.2    Deeba, S.3
  • 19
    • 28344457641 scopus 로고    scopus 로고
    • Does minimally invasive vein harvesting technique affect the quality of the conduit for coronary revascularization?
    • Aziz O., Athanasiou T., Panesar S.S., et al. Does minimally invasive vein harvesting technique affect the quality of the conduit for coronary revascularization?. Ann Thorac Surg 80 (2005) 2407-2414
    • (2005) Ann Thorac Surg , vol.80 , pp. 2407-2414
    • Aziz, O.1    Athanasiou, T.2    Panesar, S.S.3
  • 20
    • 0034959949 scopus 로고    scopus 로고
    • A comparative study of endothelial cell injury during open and endoscopic saphenectomy: an electron microscopic evaluation
    • Alrawi S.J., Balaya F., Raju R., Cunningham J.N., and Acinapura A.J. A comparative study of endothelial cell injury during open and endoscopic saphenectomy: an electron microscopic evaluation. Heart Surg Forum 4 (2001) 120-127
    • (2001) Heart Surg Forum , vol.4 , pp. 120-127
    • Alrawi, S.J.1    Balaya, F.2    Raju, R.3    Cunningham, J.N.4    Acinapura, A.J.5
  • 21
    • 0035051436 scopus 로고    scopus 로고
    • Interleukin-1, interleukin-2 and interleukin-10 expression in different techniques of saphenous vein harvesting
    • Alrawi S.J., Raju R., Satheesan R., Cunningham J.N., and Acinapaura A.J. Interleukin-1, interleukin-2 and interleukin-10 expression in different techniques of saphenous vein harvesting. Heart Surg Forum 4 (2001) 47-52
    • (2001) Heart Surg Forum , vol.4 , pp. 47-52
    • Alrawi, S.J.1    Raju, R.2    Satheesan, R.3    Cunningham, J.N.4    Acinapaura, A.J.5
  • 22
    • 0001372089 scopus 로고    scopus 로고
    • Intercellular and vascular cell adhesion molecule levels in endoscopic and open saphenous vein harvesting for coronary artery bypass surgery
    • Alrawi S.J., Samee M., Raju R., Shirazian D., Acinapura A.J., and Cunningham J.N. Intercellular and vascular cell adhesion molecule levels in endoscopic and open saphenous vein harvesting for coronary artery bypass surgery. Heart Surg Forum 3 (2000) 241-245
    • (2000) Heart Surg Forum , vol.3 , pp. 241-245
    • Alrawi, S.J.1    Samee, M.2    Raju, R.3    Shirazian, D.4    Acinapura, A.J.5    Cunningham, J.N.6
  • 23
    • 1442354302 scopus 로고    scopus 로고
    • Immunocytochemical study on endothelial integrity of saphenous vein grafts harvested by minimally invasive surgery with the use of vascular mayo stripers. A randomized controlled trial
    • Nowicki M., Buczkowski P., Miskowiak B., Konwerska A., Ostalska-Nowicka D., and Dyszkiewicz W. Immunocytochemical study on endothelial integrity of saphenous vein grafts harvested by minimally invasive surgery with the use of vascular mayo stripers. A randomized controlled trial. Eur J Vasc Endovasc Surg 27 (2004) 244-250
    • (2004) Eur J Vasc Endovasc Surg , vol.27 , pp. 244-250
    • Nowicki, M.1    Buczkowski, P.2    Miskowiak, B.3    Konwerska, A.4    Ostalska-Nowicka, D.5    Dyszkiewicz, W.6
  • 24
  • 25
    • 35448974041 scopus 로고    scopus 로고
    • Strategies to reduce intraluminal clot formation in endoscopically harvested saphenous veins
    • Brown E.N., Kon Z.N., Tran R., et al. Strategies to reduce intraluminal clot formation in endoscopically harvested saphenous veins. J Thorac Cardiovasc Surg 134 (2007) 1259-1265
    • (2007) J Thorac Cardiovasc Surg , vol.134 , pp. 1259-1265
    • Brown, E.N.1    Kon, Z.N.2    Tran, R.3
  • 26
    • 1642291858 scopus 로고    scopus 로고
    • Influence of endoscopic versus traditional saphenectomy on event-free survival: five-year follow-up of a prospective randomized trial
    • Allen K.B., Heimansohn D.A., Robison R.J., Schier J.J., Griffith G.L., and Fitzgerald E.B. Influence of endoscopic versus traditional saphenectomy on event-free survival: five-year follow-up of a prospective randomized trial. Heart Surg Forum 6 (2003) E143-E145
    • (2003) Heart Surg Forum , vol.6
    • Allen, K.B.1    Heimansohn, D.A.2    Robison, R.J.3    Schier, J.J.4    Griffith, G.L.5    Fitzgerald, E.B.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.