1
-
-
0034446654
-
The effects of drilling force on cortical temperatures and their duration: an in vitro study
-
Bachus K.N., Rondina M.T., and Hutchinson D.T. The effects of drilling force on cortical temperatures and their duration: an in vitro study. Medical Engineering & Physics 22 (2000) 685-691
-
(2000)
Medical Engineering & Physics
, vol.22
, pp. 685-691
-
-
Bachus, K.N.1
Rondina, M.T.2
Hutchinson, D.T.3
-
2
-
-
0030926314
-
Interlocking intramedullary nailing with and without reaming for the treatment of closed fractures of the tibial shaft. A prospective, randomized study
-
Blachut P.A., O'Brien P.J., Meek R.N., and Broekhuyse H.M. Interlocking intramedullary nailing with and without reaming for the treatment of closed fractures of the tibial shaft. A prospective, randomized study. The Journal of Bone and Joint Surgery 79 (1997) 640-646
-
(1997)
The Journal of Bone and Joint Surgery
, vol.79
, pp. 640-646
-
-
Blachut, P.A.1
O'Brien, P.J.2
Meek, R.N.3
Broekhuyse, H.M.4
-
3
-
-
0027244015
-
A skin and soft-tissue protector for intramedullary reaming
-
871, 5
-
Case S.R., and Hennrikus W.L. A skin and soft-tissue protector for intramedullary reaming. Orthopaedic Review 22 (1993) 871, 5
-
(1993)
Orthopaedic Review
, vol.22
-
-
Case, S.R.1
Hennrikus, W.L.2
-
4
-
-
0034152649
-
A prospective, randomized study of intramedullary nails inserted with and without reaming for the treatment of open and closed fractures of the tibial shaft
-
Finkemeier C.G., Schmidt A.H., Kyle R.F., et al. A prospective, randomized study of intramedullary nails inserted with and without reaming for the treatment of open and closed fractures of the tibial shaft. Journal of Orthopaedic Trauma 14 (2000) 187-193
-
(2000)
Journal of Orthopaedic Trauma
, vol.14
, pp. 187-193
-
-
Finkemeier, C.G.1
Schmidt, A.H.2
Kyle, R.F.3
-
5
-
-
2442421876
-
The influence of the size and condition of the reamers on bone temperature during intramedullary reaming
-
Garcia O.G., Mombiela F.L., De La Fuente C.J., et al. The influence of the size and condition of the reamers on bone temperature during intramedullary reaming. The Journal of Bone and Joint Surgery 86-A (2004) 994-999
-
(2004)
The Journal of Bone and Joint Surgery
, vol.86 -A
, pp. 994-999
-
-
Garcia, O.G.1
Mombiela, F.L.2
De La Fuente, C.J.3
-
6
-
-
0036265807
-
Friction burns within the tibia during reaming. Are they affected by the use of a tourniquet?
-
Giannoudis P.V., Snowden S., Matthews S.J., et al. Friction burns within the tibia during reaming. Are they affected by the use of a tourniquet?. The Journal of Bone and Joint Surgery 84 (2002) 492-496
-
(2002)
The Journal of Bone and Joint Surgery
, vol.84
, pp. 492-496
-
-
Giannoudis, P.V.1
Snowden, S.2
Matthews, S.J.3
-
11
-
-
1642282680
-
Should insertion of intramedullary nails for tibial fractures be with or without reaming? A prospective, randomized study with 3.8 years' follow-up
-
Larsen L.B., Madsen J.E., Hoiness P.R., and Ovre S. Should insertion of intramedullary nails for tibial fractures be with or without reaming? A prospective, randomized study with 3.8 years' follow-up. Journal of Orthopaedic Trauma 18 (2004) 144-149
-
(2004)
Journal of Orthopaedic Trauma
, vol.18
, pp. 144-149
-
-
Larsen, L.B.1
Madsen, J.E.2
Hoiness, P.R.3
Ovre, S.4
-
12
-
-
0029898183
-
Thermal necrosis after tibial reaming for intramedullary nail fixation. A report of three cases
-
Leunig M., and Hertel R. Thermal necrosis after tibial reaming for intramedullary nail fixation. A report of three cases. The Journal of Bone and Joint Surgery, British 78 (1996) 584-587
-
(1996)
The Journal of Bone and Joint Surgery, British
, vol.78
, pp. 584-587
-
-
Leunig, M.1
Hertel, R.2
-
13
-
-
0027891817
-
Intramedullary pressure, strain on the diaphysis and increase in cortical temperature when reaming the femoral medullary cavity-a comparison of blunt and sharp reamers
-
Muller C., McIff T., Rahn B.A., et al. Intramedullary pressure, strain on the diaphysis and increase in cortical temperature when reaming the femoral medullary cavity-a comparison of blunt and sharp reamers. Injury 24 Suppl. 3 (1993) S22-S30
-
(1993)
Injury
, vol.24
, Issue.SUPPL. 3
-
-
Muller, C.1
McIff, T.2
Rahn, B.A.3
-
14
-
-
0033771362
-
Technical innovations in medullary reaming: reamer design and intramedullary pressure increase
-
Muller C.A., Baumgart F., Wahl D., et al. Technical innovations in medullary reaming: reamer design and intramedullary pressure increase. The Journal of Trauma 49 (2000) 440-445
-
(2000)
The Journal of Trauma
, vol.49
, pp. 440-445
-
-
Muller, C.A.1
Baumgart, F.2
Wahl, D.3
-
16
-
-
0344109565
-
Heat-induced segmental necrosis after reaming of one humeral and two tibial fractures with a narrow medullary canal
-
Ochsner P.E., Baumgart F., and Kohler G. Heat-induced segmental necrosis after reaming of one humeral and two tibial fractures with a narrow medullary canal. Injury 29 Suppl. 2 (1998) B1-B10
-
(1998)
Injury
, vol.29
, Issue.SUPPL. 2
-
-
Ochsner, P.E.1
Baumgart, F.2
Kohler, G.3
|