메뉴 건너뛰기




Volumn 29, Issue 4, 2004, Pages 271-278

A Monte Carlo brachytherapy study for dose distribution prediction in an inhomogeneous medium

Author keywords

Brachytherapy; Iodine 125; Iridium 192; MCNP; Monte Carlo; Palladium 103

Indexed keywords

IODINE 125; IRIDIUM 192; PALLADIUM 103;

EID: 7444250181     PISSN: 09583947     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.meddos.2004.02.002     Document Type: Article
Times cited : (8)

References (21)
  • 1
    • 7444228770 scopus 로고    scopus 로고
    • Best Industries. Springfield VA, 2001
    • Best Industries. Springfield VA, 2001
  • 2
    • 7444240440 scopus 로고    scopus 로고
    • Nycomed Amersham. Arlington Heights, IL, 2001
    • Nycomed Amersham. Arlington Heights, IL, 2001
  • 3
    • 7444246942 scopus 로고    scopus 로고
    • Theragenics Corporation. Atlanta, GA, 2001
    • Theragenics Corporation. Atlanta, GA, 2001
  • 5
    • 7444266415 scopus 로고    scopus 로고
    • X-ray emitting interstitial implants. USA patent no. 5405309. Theragenics Corporation; April 11, 1995
    • Carden, J.L. X-ray emitting interstitial implants. USA patent no. 5405309. Theragenics Corporation; April 11, 1995
    • Carden, J.L.1
  • 9
    • 7444235002 scopus 로고    scopus 로고
    • Lawrence, Berkeley National Laboratory. Available at: http://ie.lbl.gov/education/isotopes.htm. Accessed May 9, 2001
  • 10
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43
    • Nath R., Anderson L.L., Luxton G., et al. Dosimetry of interstitial brachytherapy sources Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. Med. Phys. 22:1995;209-234
    • (1995) Med. Phys. , vol.22 , pp. 209-234
    • Nath, R.1    Anderson, L.L.2    Luxton, G.3
  • 11
    • 0025900734 scopus 로고
    • Comparison of measured and calculated dose rates in water near I-125 and Ir-192 seeds
    • Williamson J.F. Comparison of measured and calculated dose rates in water near I-125 and Ir-192 seeds. Med. Phys. 18:1991;776-786
    • (1991) Med. Phys. , vol.18 , pp. 776-786
    • Williamson, J.F.1
  • 15
    • 0032891406 scopus 로고    scopus 로고
    • Guidance to users of Nycomed Amersham and North American Scientific, Inc., 1-125 Interstitial Sources: Dosimetry and calibration changes: Recommendations of the American Association of Physicists in Medicine Radiation Therapy Committee Ad Hoc Subcommittee on Low-Energy Seed Dosimetry
    • Williamson J.F., Coursey B.M., DeWerd L.A., et al. Guidance to users of Nycomed Amersham and North American Scientific, Inc., 1-125 Interstitial Sources: Dosimetry and calibration changes: Recommendations of the American Association of Physicists in Medicine Radiation Therapy Committee Ad Hoc Subcommittee on Low-Energy Seed Dosimetry. Med. Phys. 26:1999;570-573
    • (1999) Med. Phys. , vol.26 , pp. 570-573
    • Williamson, J.F.1    Coursey, B.M.2    Dewerd, L.A.3
  • 17
    • 0032217054 scopus 로고    scopus 로고
    • 103Pd sources
    • 103Pd sources. Med. Phys. 25:1998;2271-2278
    • (1998) Med. Phys. , vol.25 , pp. 2271-2278
    • Weaver, K.1
  • 18
    • 0034004934 scopus 로고    scopus 로고
    • 103Pd interstitial brachytherapy source
    • 103Pd interstitial brachytherapy source. Med. Phys. 27:2000;643-654
    • (2000) Med. Phys. , vol.27 , pp. 643-654
    • Williamson, J.F.1
  • 19
  • 20
    • 0025922324 scopus 로고
    • 103Pd seeds (model 200) in solid water phantom
    • 103Pd seeds (model 200) in solid water phantom. Med. Phys. 18:1991;449-452
    • (1991) Med. Phys. , vol.18 , pp. 449-452
    • Chiu-Tsao, S.T.1    Anderson, L.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.