메뉴 건너뛰기




Volumn , Issue , 2009, Pages

Evaluation of harmonic current sidebands for broken bar diagnosis in induction motors

Author keywords

Broken rotor bars; Fault diagnosis; Induction motors

Indexed keywords

BROKEN BAR; BROKEN BAR DIAGNOSIS; BROKEN ROTOR BAR; COUPLED-CIRCUIT MODEL; FAULT DIAGNOSIS; HARMONIC CURRENT SIDEBANDS; HARMONICS CURRENT; LOAD INERTIA; ROTOR FAULT; ROTOR FAULT DIAGNOSIS; STATOR CURRENTS;

EID: 74349126899     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/DEMPED.2009.5292798     Document Type: Conference Paper
Times cited : (18)

References (15)
  • 1
    • 0035439141 scopus 로고    scopus 로고
    • Quantitative evaluation of induction motor broken bars by means of electrical signature analysis
    • A. Bellini, F. Filippetti, G. Franceschini, C. Tassoni, and G.B. Kliman, "Quantitative evaluation of induction motor broken bars by means of electrical signature analysis," IEEE Trans. on Industry Applications, vol. 37, no. 5, pp. 1248-1255, 2001.
    • (2001) IEEE Trans. on Industry Applications , vol.37 , Issue.5 , pp. 1248-1255
    • Bellini, A.1    Filippetti, F.2    Franceschini, G.3    Tassoni, C.4    Kliman, G.B.5
  • 2
    • 77957803193 scopus 로고    scopus 로고
    • Influence of the motor load inertia and torque in the fault diagnosis of rotors in induction machines
    • C.J. Verucchi, G.G. Acosta, and E. Carusso, "Influence of the motor load inertia and torque in the fault diagnosis of rotors in induction machines," IEEE Latin America Transactions, vol. 3, no. 4, pp. 48-53, 2005.
    • (2005) IEEE Latin America Transactions , vol.3 , Issue.4 , pp. 48-53
    • Verucchi, C.J.1    Acosta, G.G.2    Carusso, E.3
  • 4
    • 40449096322 scopus 로고    scopus 로고
    • Low order PWM inverter harmonics contributions to the inverter-fed induction machine fault Diagnosis
    • B. Akin, U. Orguner, H.A. Toliyat, and M. Rayner, "Low Order PWM Inverter Harmonics Contributions to the Inverter-Fed Induction Machine Fault Diagnosis," IEEE Trans. on Industrial Electronics, vol. 55, no. 2, pp. 610-619, 2008.
    • (2008) IEEE Trans. on Industrial Electronics , vol.55 , Issue.2 , pp. 610-619
    • Akin, B.1    Orguner, U.2    Toliyat, H.A.3    Rayner, M.4
  • 7
    • 57749200463 scopus 로고    scopus 로고
    • Analysis and application of particular current signatures (Symptoms) for cage monitoring in nonsinusoidally fed motors with high rejection to drive load, inertia, and frequency variations
    • C. Bruzzese, "Analysis and Application of Particular Current Signatures (Symptoms) for Cage Monitoring in Nonsinusoidally Fed Motors With High Rejection to Drive Load, Inertia, and Frequency Variations," IEEE Trans. on Industrial Electronics, vol. 55, pp. 4137-4155, 2008.
    • (2008) IEEE Trans. on Industrial Electronics , vol.55 , pp. 4137-4155
    • Bruzzese, C.1
  • 8
    • 20544439623 scopus 로고    scopus 로고
    • Analytical approach of the stator current frequency harmonics computation for detection of induction machine rotor faults
    • H. Henao, H. Razik, and G.A. Capolino, "Analytical approach of the stator current frequency harmonics computation for detection of induction machine rotor faults," IEEE Trans. on Industry Applications, Vol.41, No.3, pp. 801-807, 2005.
    • (2005) IEEE Trans. on Industry Applications , vol.41 , Issue.3 , pp. 801-807
    • Henao, H.1    Razik, H.2    Capolino, G.A.3
  • 9
    • 84861518172 scopus 로고    scopus 로고
    • Diagnostics of rotor-cage faults supported by effects due to higher MMF harmonics
    • Bologna
    • T.J. Sobczyk and W. Maciolek, "Diagnostics of rotor-cage faults supported by effects due to higher MMF harmonics," IEEE Power Tech Conference Proceedings, Bologna, vol.2, 2003.
    • (2003) IEEE Power Tech Conference Proceedings , vol.2
    • Sobczyk, T.J.1    Maciolek, W.2
  • 10
    • 1542346033 scopus 로고    scopus 로고
    • A 2D- Model of the induction motor: An extension of the modified winding function approach
    • G. Bossio, C. De Angelo, J. Solsona, G. García, and M. I. Valla, "A 2D- Model of the Induction Motor: An Extension of the Modified Winding Function Approach," IEEE Trans. on Energy Conversion, vol. 19, no. 1, pp. 144-150, 2004.
    • (2004) IEEE Trans. on Energy Conversion , vol.19 , Issue.1 , pp. 144-150
    • Bossio, G.1    De Angelo, C.2    Solsona, J.3    García, G.4    Valla, M.I.5
  • 12
    • 0029321518 scopus 로고
    • Transient analysis of cage induction machines under stator, rotor bar and end ring faults
    • 1995
    • H.A. Toliyat and T. A. Lipo (1995), "Transient Analysis of Cage Induction Machines Under Stator, Rotor Bar and End Ring Faults," IEEE Trans. on Energy Conversion, vol. 10, no. 2, pp. 241-247, 1995.
    • (1995) IEEE Trans. on Energy Conversion , vol.10 , Issue.2 , pp. 241-247
    • Toliyat, H.A.1    Lipo, T.A.2
  • 13
    • 23644456175 scopus 로고    scopus 로고
    • Effects of rotor bar and end-ring faults over the signals of a position estimation strategy for induction motors
    • G. Bossio, C. De Angelo, J. Solsona, G. García, and M. I. Valla, "Effects of Rotor Bar and End-Ring Faults Over the Signals of a Position Estimation Strategy for Induction Motors," IEEE Trans. on Industry Applications, vol. 41, no. 4, pp. 1005-1012, 2005.
    • (2005) IEEE Trans. on Industry Applications , vol.41 , Issue.4 , pp. 1005-1012
    • Bossio, G.1    De Angelo, C.2    Solsona, J.3    García, G.4    Valla, M.I.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.