Should recent defibrillator and lead advisories affect decisions to refer patients for implantable cardioverter-defibrillator therapy?

Author keywords

Advisory; Device malfunction; Implantable cardioverter defibrillator; Lead fracture; Recall

Indexed keywords

CONTROLLED STUDY; COST EFFECTIVENESS ANALYSIS; DEFIBRILLATOR; DEVICE REMOVAL; EMOTIONAL STRESS; EQUIPMENT; EQUIPMENT DESIGN; FOOD AND DRUG ADMINISTRATION; GENERATOR; HEART VENTRICLE ARRHYTHMIA; HUMAN; MEDICAL DECISION MAKING; PACEMAKER FAILURE; PATIENT COUNSELING; PATIENT REFERRAL; POSTMARKETING SURVEILLANCE; PRIORITY JOURNAL; QUALITY ADJUSTED LIFE YEAR; RELIABILITY; REVIEW; RISK ASSESSMENT; TREATMENT INDICATION;

EID: 74249096367     PISSN: 02684705     EISSN: None     Source Type: Journal    
DOI: 10.1097/HCO.0b013e328333d375     Document Type: Review
Times cited : (4)

References (25)
  • 1
    • 33749061476 scopus 로고    scopus 로고
    • Recommendations from the Heart Rhythm Society task force on device performance policies and guidelines
    • Carlson MD, Wilkoff BL, Maisel WH, et al. Recommendations from the Heart Rhythm Society task force on device performance policies and guidelines. Heart Rhythm 2006; 3:1250-1273.
    • (2006) Heart Rhythm , vol.3 , pp. 1250-1273
    • Carlson, M.D.1    Wilkoff, B.L.2    Maisel, W.H.3
  • 2
    • 23944466429 scopus 로고    scopus 로고
    • Safety issues involving medical devices: Implications of recent implantable cardioverter-defibrillator malfunctions
    • 5
    • Maisel WH. Safety issues involving medical devices: implications of recent implantable cardioverter-defibrillator malfunctions. JAMA 2005; 294:955- 958; 5.
    • (2005) JAMA , vol.294 , pp. 955-958
    • Maisel, W.H.1
  • 3
    • 33646164892 scopus 로고    scopus 로고
    • Pacemaker and ICD generator malfunctions: Analysis of Food and Drug Administration annual reports
    • Maisel WH, Moynahan M, Zuckerman BD, et al. Pacemaker and ICD generator malfunctions: analysis of Food and Drug Administration annual reports. JAMA 2006; 295:1901-1906.
    • (2006) JAMA , vol.295 , pp. 1901-1906
    • Maisel, W.H.1    Moynahan, M.2    Zuckerman, B.D.3
  • 4
    • 0035880307 scopus 로고    scopus 로고
    • Recalls and safety alerts involving pacemakers and implantable cardioverter-defibrillator generators
    • Maisel WH, Sweeney MO, Stevenson WG, et al. Recalls and safety alerts involving pacemakers and implantable cardioverter-defibrillator generators. JAMA 2001; 286:793-799.
    • (2001) JAMA , vol.286 , pp. 793-799
    • Maisel, W.H.1    Sweeney, M.O.2    Stevenson, W.G.3
  • 5
    • 33744464490 scopus 로고    scopus 로고
    • Life-threatening malfunction of implantable cardiac devices
    • Myerburg RJ, Feigal DW, Lindsay BD. Life-threatening malfunction of implantable cardiac devices. N Engl J Med 2006; 354:2309-2311.
    • (2006) N Engl J Med , vol.354 , pp. 2309-2311
    • Myerburg, R.J.1    Feigal, D.W.2    Lindsay, B.D.3
  • 6
    • 1842843869 scopus 로고    scopus 로고
    • Physician management of pacemaker and implantable cardioverter- defibrillator advisories
    • Maisel WH. Physician management of pacemaker and implantable cardioverter- defibrillator advisories. Pacing Clin Electrophysiol 2004; 27:437-442.
    • (2004) Pacing Clin Electrophysiol , vol.27 , pp. 437-442
    • Maisel, W.H.1
  • 7
    • 0033534084 scopus 로고    scopus 로고
    • Risks of spontaneous injury and extraction of an active fixation pacemaker lead: Report of the Accufix Multicenter Clinical Study and Worldwide Registry
    • 12
    • Kay GN, Brinker JA, Kawanishi DT, et al. Risks of spontaneous injury and extraction of an active fixation pacemaker lead: report of the Accufix Multicenter Clinical Study and Worldwide Registry. Circulation 1999; 100:2344- 2352; 12.
    • (1999) Circulation , vol.100 , pp. 2344-2352
    • Kay, G.N.1    Brinker, J.A.2    Kawanishi, D.T.3
  • 8
    • 33646121985 scopus 로고    scopus 로고
    • Pacemaker and ICD generator reliability: Meta-analysis of device registries
    • Maisel WH. Pacemaker and ICD generator reliability: meta-analysis of device registries. JAMA 2006; 295:1929-1934.
    • (2006) JAMA , vol.295 , pp. 1929-1934
    • Maisel, W.H.1
  • 9
    • 15344342129 scopus 로고    scopus 로고
    • Sophisticated remote implantable cardioverter- defibrillator follow-up: A status report
    • Schoenfeld MH, Reynolds DW. Sophisticated remote implantable cardioverter- defibrillator follow-up: a status report. Pacing Clin Electrophysiol 2005; 28:235-240.
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 235-240
    • Schoenfeld, M.H.1    Reynolds, D.W.2
  • 10
    • 63049115287 scopus 로고    scopus 로고
    • Remote monitoring for advisories: Automatic early detection of silent lead failure
    • Varma N. Remote monitoring for advisories: automatic early detection of silent lead failure. Pacing Clin Electrophysiol 2009; 32:525-527.
    • (2009) Pacing Clin Electrophysiol , vol.32 , pp. 525-527
    • Varma, N.1
  • 11
    • 33646130849 scopus 로고    scopus 로고
    • Complications associated with implantable cardioverterdefibrillator replacement in response to device advisories
    • Canadian Heart Rhythm Society Working Group on Device Advisories
    • Gould PA, Krahn AD, Canadian Heart Rhythm Society Working Group on Device Advisories. Complications associated with implantable cardioverterdefibrillator replacement in response to device advisories. JAMA 2006; 295:1907-1911.
    • (2006) JAMA , vol.295 , pp. 1907-1911
    • Gould, P.A.1    Krahn, A.D.2
  • 12
    • 57249094409 scopus 로고    scopus 로고
    • Outcome of advisory implantable cardioverter-defibrillator replacement: One-year follow-up
    • Gould PA, Gula LJ, Champagne J, et al. Outcome of advisory implantable cardioverter-defibrillator replacement: one-year follow-up. Heart Rhythm 2008; 5:1675-1681.
    • (2008) Heart Rhythm , vol.5 , pp. 1675-1681
    • Gould, P.A.1    Gula, L.J.2    Champagne, J.3
  • 13
    • 34249783107 scopus 로고    scopus 로고
    • Complication risk with pulse generator change: Implications when reacting to a device advisory or recall
    • Kapa S, Hyberger L, Rea RF, Hayes DL. Complication risk with pulse generator change: implications when reacting to a device advisory or recall. Pacing Clin Electrophysiol 2007; 30:730-733.
    • (2007) Pacing Clin Electrophysiol , vol.30 , pp. 730-733
    • Kapa, S.1    Hyberger, L.2    Rea, R.F.3    Hayes, D.L.4
  • 14
    • 39749164518 scopus 로고    scopus 로고
    • Complications associated with generator replacement in response to device advisories
    • Costea A, Rardon DP, Padanilam BJ, et al. Complications associated with generator replacement in response to device advisories. J Cardiovasc Electrophysiol 2008; 19:266-269.
    • (2008) J Cardiovasc Electrophysiol , vol.19 , pp. 266-269
    • Costea, A.1    Rardon, D.P.2    Padanilam, B.J.3
  • 15
    • 33746430581 scopus 로고    scopus 로고
    • Management of recalled pacemakers and implantable cardioverter- defibrillators: A decision analysis model
    • Amin MS, Matchar DB, Wood MA, Ellenbogen KA. Management of recalled pacemakers and implantable cardioverter-defibrillators: a decision analysis model. JAMA 2006; 296:412-420.
    • (2006) JAMA , vol.296 , pp. 412-420
    • Amin, M.S.1    Matchar, D.B.2    Wood, M.A.3    Ellenbogen, K.A.4
  • 16
    • 33846262530 scopus 로고    scopus 로고
    • Survival rates as a guide to implanted cardioverter-defibrillator replacement strategies for device recalls: Adding statistical insight to clinical intuition
    • Gula LJ, Massel D, Krahn AD, et al. Survival rates as a guide to implanted cardioverter-defibrillator replacement strategies for device recalls: adding statistical insight to clinical intuition. Am Heart J 2007; 153:253-259.
    • (2007) Am Heart J , vol.153 , pp. 253-259
    • Gula, L.J.1    Massel, D.2    Krahn, A.D.3
  • 17
    • 61349144388 scopus 로고    scopus 로고
    • To replace or not to replace: A systematic approach to respond to device advisories
    • Priori SG, Auricchio A, Nisam S, Yong P. To replace or not to replace: a systematic approach to respond to device advisories. J Cardiovasc Electrophysiol 2009; 20:164-170.
    • (2009) J Cardiovasc Electrophysiol , vol.20 , pp. 164-170
    • Priori, S.G.1    Auricchio, A.2    Nisam, S.3    Yong, P.4
  • 18
    • 51849132596 scopus 로고    scopus 로고
    • Clinical judgment versus decision analysis for managing device advisories
    • Amin MS, Wood MA, Shepard RK, et al. Clinical judgment versus decision analysis for managing device advisories. Pacing Clin Electrophysiol 2008; 31:1236-1240.
    • (2008) Pacing Clin Electrophysiol , vol.31 , pp. 1236-1240
    • Amin, M.S.1    Wood, M.A.2    Shepard, R.K.3
  • 19
    • 85068098136 scopus 로고    scopus 로고
    • Lead extraction in the contemporary setting: The LExICon study, an observational retrospective study of consecutive laser lead extractions
    • (in press)
    • Wazni O, Epstein LM, Carrillo RG, et al. Lead extraction in the contemporary setting: the LExICon study, an observational retrospective study of consecutive laser lead extractions. J Am Coll Cardiol (in press).
    • J Am Coll Cardiol
    • Wazni, O.1    Epstein, L.M.2    Carrillo, R.G.3
  • 20
    • 56749164951 scopus 로고    scopus 로고
    • Benefit of primary prevention implantable cardioverter-defibrillators in the setting of chronic kidney disease: A decision model analysis
    • Amin MS, Fox AD, KalahastyG, et al. Benefit of primary prevention implantable cardioverter-defibrillators in the setting of chronic kidney disease: a decision model analysis. J Cardiovasc Electrophysiol 2008; 19:1275-1280.
    • (2008) J Cardiovasc Electrophysiol , vol.19 , pp. 1275-1280
    • Amin, M.S.1    Fox, A.D.2    Kalahasty, G.3
  • 21
    • 70349508573 scopus 로고    scopus 로고
    • Impact of age and medical comorbidity on the effectiveness of implantable cardioverter-defibrillators for primary prevention
    • Chan PS, Nallamothu BK, Spertus JA, et al. Impact of age and medical comorbidity on the effectiveness of implantable cardioverter-defibrillators for primary prevention. Circ Cardiovasc Qual Outcomes 2009; 2:16-24.
    • (2009) Circ Cardiovasc Qual Outcomes , vol.2 , pp. 16-24
    • Chan, P.S.1    Nallamothu, B.K.2    Spertus, J.A.3
  • 22
    • 74249095699 scopus 로고    scopus 로고
    • Cost-effectiveness of the implantable cardioverter defibrillator in the elderly
    • Sanders GD, Kong M, Al-Khatib SN, Peterson ED. Cost-effectiveness of the implantable cardioverter defibrillator in the elderly. Circulation 2008; 118:S1118.
    • (2008) Circulation , vol.118
    • Sanders, G.D.1    Kong, M.2    Al-Khatib, S.N.3    Peterson, E.D.4
  • 23
    • 42649092531 scopus 로고    scopus 로고
    • Outcomes and costs of implantable cardioverter-defibrillators for primary prevention of sudden cardiac death among the elderly
    • Groeneveld PW, Farmer SA, Suh JJ, et al. Outcomes and costs of implantable cardioverter-defibrillators for primary prevention of sudden cardiac death among the elderly. Heart Rhythm 2008; 5:646-653.
    • (2008) Heart Rhythm , vol.5 , pp. 646-653
    • Groeneveld, P.W.1    Farmer, S.A.2    Suh, J.J.3
  • 24
    • 58149096524 scopus 로고    scopus 로고
    • No long-term psychological morbidity living with an implantable cardioverter defibrillator under advisory: The Medtronic Marquis experience
    • Birnie DH, Sears SF, Green MS, et al. No long-term psychological morbidity living with an implantable cardioverter defibrillator under advisory: the Medtronic Marquis experience. Europace 2009; 11:26-30.
    • (2009) Europace , vol.11 , pp. 26-30
    • Birnie, D.H.1    Sears, S.F.2    Green, M.S.3
  • 25
    • 44349142267 scopus 로고    scopus 로고
    • Decision-making, emotional distress, and quality of life in patients affected by the recall of their implantable cardioverter defibrillator
    • Gibson DP, Kuntz KK, Levenson JL, Ellenbogen KA. Decision-making, emotional distress, and quality of life in patients affected by the recall of their implantable cardioverter defibrillator. Europace 2008; 10:540-544.
    • (2008) Europace , vol.10 , pp. 540-544
    • Gibson, D.P.1    Kuntz, K.K.2    Levenson, J.L.3    Ellenbogen, K.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.