Volumn 21, Issue 2, 2010, Pages 242-248

Controlling the Expansion into Vacuum-the Enabling Technology for Trapping Atmosphere-Sampled Particulate Ions

Author keywords

[No Author keywords available]

Indexed keywords

APPLIED FIELD; BUFFER GAS; CAPTURE EFFICIENCY; COLLISIONAL COOLING; ENABLING TECHNOLOGIES; HIGH RESOLUTION MASS SPECTROMETRY; INTACT PROTEINS; ION INJECTION; KINETIC ENERGY DISTRIBUTIONS; LINEAR QUADRUPOLE ION TRAPS; LOW MASS; MASS ANALYSIS; ON-DEMAND; TRAPPED ION; TRAPPING IONS; TRAPPING SYSTEMS; UPPER LIMITS; WORKING RANGE;

EID: 74249091919     PISSN: 10440305     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jasms.2009.10.009     Document Type: Article
Times cited : (12)

References (15)
  • 1
    • 0024438708 scopus 로고
    • Electrospray Ionization for Mass-Spectrometry of Large Biomolecules
    • Fenn J.B., Mann M., Meng C.K., Wong S.F., and Whitehouse C.M. Electrospray Ionization for Mass-Spectrometry of Large Biomolecules. Science 246 (1989) 64-71
    • (1989) Science , vol.246 , pp. 64-71
    • Fenn, J.B.1    Mann, M.2    Meng, C.K.3    Wong, S.F.4    Whitehouse, C.M.5
  • 2
    • 0024289037 scopus 로고
    • Laser Desorption Ionization Of Proteins with Molecular Masses Exceeding 10,000 Daltons
    • Karas M., and Hillenkamp F. Laser Desorption Ionization Of Proteins with Molecular Masses Exceeding 10,000 Daltons. Anal. Chem. 60 (1988) 2299-2301
    • (1988) Anal. Chem. , vol.60 , pp. 2299-2301
    • Karas, M.1    Hillenkamp, F.2
  • 3
    • 27544477378 scopus 로고    scopus 로고
    • Analysis of Megadalton Ions Using Cryodetection MALDI Time-of-Flight Mass Spectrometry
    • Wenzel R.J., Matter U., Schultheis L., and Zenobi R. Analysis of Megadalton Ions Using Cryodetection MALDI Time-of-Flight Mass Spectrometry. Anal. Chem. 77 (2005) 4329-4337
    • (2005) Anal. Chem. , vol.77 , pp. 4329-4337
    • Wenzel, R.J.1    Matter, U.2    Schultheis, L.3    Zenobi, R.4
  • 4
    • 31544445500 scopus 로고    scopus 로고
    • Multimers of the Fibroblast Growth Factor (FGF)-FGF Receptor-Saccharide Complex are Formed on Long Oligomers of Heparin
    • Harmer N.J., Robinson C.J., Adam L.E., Ilag L.L., Robinson C.V., Gallagher J.T., and Blundell T.L. Multimers of the Fibroblast Growth Factor (FGF)-FGF Receptor-Saccharide Complex are Formed on Long Oligomers of Heparin. Biochem. J. 393 (2006) 741-748
    • (2006) Biochem. J. , vol.393 , pp. 741-748
    • Harmer, N.J.1    Robinson, C.J.2    Adam, L.E.3    Ilag, L.L.4    Robinson, C.V.5    Gallagher, J.T.6    Blundell, T.L.7
  • 5
    • 1542723081 scopus 로고    scopus 로고
    • Collisional Cooling of Large Ions in Electrospray Mass Spectrometry
    • Chernushevich I.V., and Thomson B.A. Collisional Cooling of Large Ions in Electrospray Mass Spectrometry. Anal. Chem. 76 (2004) 1754-1760
    • (2004) Anal. Chem. , vol.76 , pp. 1754-1760
    • Chernushevich, I.V.1    Thomson, B.A.2
  • 7
    • 77956859716 scopus 로고
    • Radiofrequency Spectroscopy of Stored Ions
    • Dehmelt H.G. Radiofrequency Spectroscopy of Stored Ions. Adv. At. Mol. Phys. 3 (1967) 53-72
    • (1967) Adv. At. Mol. Phys. , vol.3 , pp. 53-72
    • Dehmelt, H.G.1
  • 8
    • 56949101081 scopus 로고    scopus 로고
    • Trapping of Intact, Singly-Charged, Bovine Serum Albumin Ions Injected from the Atmosphere with a 10-cm Diameter, Frequency-Adjusted Linear Quadrupole Ion Trap
    • Koizumi H., Whitten W.B., and Reilly P.T.A. Trapping of Intact, Singly-Charged, Bovine Serum Albumin Ions Injected from the Atmosphere with a 10-cm Diameter, Frequency-Adjusted Linear Quadrupole Ion Trap. J. Am. Soc. Mass Spectrom. 19 (2008) 1942-1947
    • (2008) J. Am. Soc. Mass Spectrom. , vol.19 , pp. 1942-1947
    • Koizumi, H.1    Whitten, W.B.2    Reilly, P.T.A.3
  • 11
    • 74249092038 scopus 로고
    • Proceedings of the International Conference on Mass Spectrometry Kyoto, Japan
    • Hayashi T., and Sakudo N. Proceedings of the International Conference on Mass Spectrometry (1969) 263 Kyoto, Japan
    • (1969) , pp. 263
    • Hayashi, T.1    Sakudo, N.2
  • 12
    • 41049083292 scopus 로고    scopus 로고
    • Mapping the Stability Diagram of a Digital Ion Trap (DIT) Mass Spectrometer Varying the Duty Cycle of the Trapping Rectangular Waveform
    • Berton A., Traldi P., Ding L., and Brancia F.L. Mapping the Stability Diagram of a Digital Ion Trap (DIT) Mass Spectrometer Varying the Duty Cycle of the Trapping Rectangular Waveform. J. Am. Soc. Mass Spectrom. 19 (2008) 620-625
    • (2008) J. Am. Soc. Mass Spectrom. , vol.19 , pp. 620-625
    • Berton, A.1    Traldi, P.2    Ding, L.3    Brancia, F.L.4
  • 13
    • 0029278150 scopus 로고
    • Generating Particle Beams of Controlled Dimensions and Divergence. 2. Experimental Evaluation of Particle Motion in Aerodynamic Lenses and Nozzle Expansions
    • Liu P., Ziemann P.J., Kittelson D.B., and McMurry P.H. Generating Particle Beams of Controlled Dimensions and Divergence. 2. Experimental Evaluation of Particle Motion in Aerodynamic Lenses and Nozzle Expansions. Aerosol Sci. Technol. 22 (1995) 314-324
    • (1995) Aerosol Sci. Technol. , vol.22 , pp. 314-324
    • Liu, P.1    Ziemann, P.J.2    Kittelson, D.B.3    McMurry, P.H.4
  • 14
    • 0029278226 scopus 로고
    • Generating Particle Beams of Controlled Dimensions and Divergence. 1. Theory of Particle Motion in Aerodynamic Lenses and Nozzle Expansions
    • Liu P., Ziemann P.J., Kittelson D.B., and McMurry P.H. Generating Particle Beams of Controlled Dimensions and Divergence. 1. Theory of Particle Motion in Aerodynamic Lenses and Nozzle Expansions. Aerosol. Sci. Technol. 22 (1995) 293-313
    • (1995) Aerosol. Sci. Technol. , vol.22 , pp. 293-313
    • Liu, P.1    Ziemann, P.J.2    Kittelson, D.B.3    McMurry, P.H.4
  • 15


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.