Volumn 37, Issue 2, 2010, Pages 494-496

Transcatheter aortic valve prosthesis surgically replaced 4 months after implantation

Author keywords

Aortic valve; Aortic valve replacement; Re do procedure; Transcatheter aortic valve implantation

Indexed keywords

AGED; ANGIOCARDIOGRAPHY; AORTA VALVE PROSTHESIS; AORTA VALVE STENOSIS; ARTICLE; BIOPROSTHESIS; CASE REPORT; CLINICAL ASSESSMENT; CORONARY ARTERY BYPASS GRAFT; CORONARY ARTERY OBSTRUCTION; ECHOCARDIOGRAPHY; HEART LEFT VENTRICLE EJECTION FRACTION; HIGH RISK PATIENT; HUMAN; MALE; OUTCOME ASSESSMENT; PERCUTANEOUS CORONARY INTERVENTION; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; REOPERATION; SURGICAL APPROACH; SURGICAL RISK; SURGICAL TECHNIQUE;

EID: 74149088476     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejcts.2009.08.028     Document Type: Article
Times cited : (19)

References (6)
  • 2
    • 65149095001 scopus 로고    scopus 로고
    • Outcomes and safety of percutaneous aortic valve replacement
    • Zajarias A., and Cribier A.G. Outcomes and safety of percutaneous aortic valve replacement. J Am Coll Cardiol 53 20 (2009) 1829-1836
    • (2009) J Am Coll Cardiol , vol.53 , Issue.20 , pp. 1829-1836
    • Zajarias, A.1    Cribier, A.G.2
  • 3
    • 65549146926 scopus 로고    scopus 로고
    • Implantation of two self-expanding aortic bioprosthetic valves during the same procedure-Insights into valve-in-valve implantation ("Russian doll concept")
    • Piazza N., Schultz C., de Jaegere P.P., and Serruys P.W. Implantation of two self-expanding aortic bioprosthetic valves during the same procedure-Insights into valve-in-valve implantation ("Russian doll concept"). Catheter Cardiovasc Interv 73 4 (2009) 530-539
    • (2009) Catheter Cardiovasc Interv , vol.73 , Issue.4 , pp. 530-539
    • Piazza, N.1    Schultz, C.2    de Jaegere, P.P.3    Serruys, P.W.4
  • 5
    • 55849132881 scopus 로고    scopus 로고
    • Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: results from the multicentre, expanded evaluation registry 1-year following CE mark approval
    • Piazza N., Grube E., Gerckens U., den Heijer P., Linke A., Luha O., Ramondo A., Ussia G., Wenaweser P., Windecker S., Laborde J.C., de Jaegere P.P., and Serruys P.W. Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: results from the multicentre, expanded evaluation registry 1-year following CE mark approval. EuroIntervention 4 2 (2008) 242-249
    • (2008) EuroIntervention , vol.4 , Issue.2 , pp. 242-249
    • Piazza, N.1    Grube, E.2    Gerckens, U.3    den Heijer, P.4    Linke, A.5    Luha, O.6    Ramondo, A.7    Ussia, G.8    Wenaweser, P.9    Windecker, S.10    Laborde, J.C.11    de Jaegere, P.P.12    Serruys, P.W.13