Volumn 84, Issue 2, 2010, Pages 183-195

Experimental study of a mechanically ventilated double-skin façade with venetian sun-shading device: A full-scale investigation in controlled environment

Author keywords

Double skin fa ade; Full scale experiment; Mechanical ventilation; Venetian sun shading device

Indexed keywords

RENEWABLE ENERGY RESOURCES; SOLAR ENERGY;

EID: 74149086944     PISSN: 0038092X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.solener.2009.10.017     Document Type: Article
Times cited : (44)

References (8)
  • 1
    • 0023293499 scopus 로고
    • Thermal experiments of full-scale dwelling cells in artificial climatic conditions
    • Allard F., Brau J., Inard C., and Pallier J.M. Thermal experiments of full-scale dwelling cells in artificial climatic conditions. Energy and Buildings 10 (1987) 49-58
    • (1987) Energy and Buildings , vol.10 , pp. 49-58
    • Allard, F.1    Brau, J.2    Inard, C.3    Pallier, J.M.4
  • 3
    • 34447645795 scopus 로고    scopus 로고
    • Experimental assessment of the performance of an active façade during actual operating conditions
    • Corgnati S.P., Perino M., and Serra V. Experimental assessment of the performance of an active façade during actual operating conditions. Solar Energy 81 (2007) 993-1013
    • (2007) Solar Energy , vol.81 , pp. 993-1013
    • Corgnati, S.P.1    Perino, M.2    Serra, V.3
  • 5
    • 4344583337 scopus 로고    scopus 로고
    • Real-time optimization of a double-skin façade based on lumped modelling and occupant preference
    • Park C., Augenbroe G., Sadegh N., Thitisawat M., and Messadi T. Real-time optimization of a double-skin façade based on lumped modelling and occupant preference. Building and Environment 39 (2004) 939-948
    • (2004) Building and Environment , vol.39 , pp. 939-948
    • Park, C.1    Augenbroe, G.2    Sadegh, N.3    Thitisawat, M.4    Messadi, T.5
  • 6
    • 1942420273 scopus 로고    scopus 로고
    • Natural ventilation in high-rise buildings with double façades, saving or waste of energy
    • Pasquay T. Natural ventilation in high-rise buildings with double façades, saving or waste of energy. Energy and Buildings 36 (2004) 381-389
    • (2004) Energy and Buildings , vol.36 , pp. 381-389
    • Pasquay, T.1
  • 7
    • 13244284807 scopus 로고    scopus 로고
    • Symbiosis of the double-skin façade with the HVAC system
    • Stec W.J., and Van Paassen A.H.C. Symbiosis of the double-skin façade with the HVAC system. Energy and Buildings 37 (2005) 61-469
    • (2005) Energy and Buildings , vol.37 , pp. 61-469
    • Stec, W.J.1    Van Paassen, A.H.C.2
  • 8
    • 74149093068 scopus 로고    scopus 로고
    • Streicher, W., 2005. Bestfaçade - Best Practice for Double Skin Façades EIE/04/135/S07.38652. WP 1 Report State of the Art.
    • Streicher, W., 2005. Bestfaçade - Best Practice for Double Skin Façades EIE/04/135/S07.38652. WP 1 Report State of the Art.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.