메뉴 건너뛰기




Volumn 251, Issue 1, 2010, Pages 127-132

Intra-abdominal pressure measurement method via the urinary-tube: Bedside validation of a biomechanical model integrating urine column height and bladder urinary volume

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL DISEASE; ABDOMINAL PRESSURE; ADULT; AGED; ARTICLE; BIOLOGICAL MODEL; BLADDER COMPLIANCE; BLADDER PRESSURE; BLADDER WALL; CONTROLLED STUDY; CRITICALLY ILL PATIENT; DIAGNOSTIC ACCURACY; FEMALE; GOLD STANDARD; HUMAN; HYPERTENSION; INTENSIVE CARE UNIT; INTERMETHOD COMPARISON; INTRA ABDOMINAL HYPERTENSION; MAJOR CLINICAL STUDY; MALE; POINT OF CARE TESTING; PRESSURE MEASUREMENT; PRESSURE TRANSDUCER; PRIORITY JOURNAL; SCREENING TEST; TUBE; URINE DRAINAGE TUBE; URINE VOLUME; BLADDER; BLADDER CATHETERIZATION; COMPARTMENT SYNDROME; HOSPITAL INFORMATION SYSTEM; INSTRUMENTATION; PERITONEAL CAVITY; PHYSIOLOGY; PRESSURE; SENSITIVITY AND SPECIFICITY; URODYNAMICS; VALIDATION STUDY;

EID: 74049143098     PISSN: 00034932     EISSN: 15281140     Source Type: Journal    
DOI: 10.1097/SLA.0b013e3181b5919b     Document Type: Article
Times cited : (16)

References (40)
  • 1
    • 33750217742 scopus 로고    scopus 로고
    • Results from the international conference of experts on intra-abdominal hypertension and abdominal compartment syndrome. I. Definitions
    • Malbrain ML, Cheatham ML, Kirkpatrick A, et al. Results from the international conference of experts on intra-abdominal hypertension and abdominal compartment syndrome. I. Definitions. Intensive Care Med. 2006;32:1722-1732.
    • (2006) Intensive Care Med , vol.32 , pp. 1722-1732
    • Malbrain, M.L.1    Cheatham, M.L.2    Kirkpatrick, A.3
  • 2
    • 34047128205 scopus 로고    scopus 로고
    • Consensus conference definitions and recommendations on intra-abdominal hypertension (IAH) and the abdominal compartment syndrome (ACS)-the long road to the final publications, how did we get there?
    • Malbrain ML, De laet I, Cheatham M. Consensus conference definitions and recommendations on intra-abdominal hypertension (IAH) and the abdominal compartment syndrome (ACS)-the long road to the final publications, how did we get there? Acta Clin Belg Suppl. 2007:44-59.
    • (2007) Acta Clin Belg Suppl , pp. 44-59
    • Malbrain, M.L.1    De Laet, I.2    Cheatham, M.3
  • 3
    • 13444252257 scopus 로고    scopus 로고
    • Incidence and prognosis of intraabdominal hypertension in a mixed population of critically ill patients: A multiple-center epidemiological study
    • Malbrain ML, Chiumello D, Pelosi P, et al. Incidence and prognosis of intraabdominal hypertension in a mixed population of critically ill patients: a multiple-center epidemiological study. Crit Care Med. 2005;33:315-322
    • (2005) Crit Care Med , vol.33 , pp. 315-322
    • Malbrain, M.L.1    Chiumello, D.2    Pelosi, P.3
  • 4
    • 35148813095 scopus 로고    scopus 로고
    • Intra-abdominal hypertension and the abdominal compartment syndrome
    • Ball CG, Kirkpatrick AW. Intra-abdominal hypertension and the abdominal compartment syndrome. Scand J Surg. 2007;96:197-204.
    • (2007) Scand J Surg , vol.96 , pp. 197-204
    • Ball, C.G.1    Kirkpatrick, A.W.2
  • 5
    • 33847680962 scopus 로고    scopus 로고
    • Secondary abdominal compartment syndrome: A potential threat for all trauma clinicians
    • Balogh Z, Moore FA, Moore EE, et al. Secondary abdominal compartment syndrome: a potential threat for all trauma clinicians. Injury. 2007;38:272-279.
    • (2007) Injury , vol.38 , pp. 272-279
    • Balogh, Z.1    Moore, F.A.2    Moore, E.E.3
  • 6
    • 33847653298 scopus 로고    scopus 로고
    • Results from the international conference of experts on intra-abdominal hypertension and abdominal compartment syndrome. II. Recommendations
    • Cheatham ML, Malbrain ML, Kirkpatrick A, et al. Results from the International Conference of Experts on Intra-abdominal Hypertension and Abdominal Compartment Syndrome. II. Recommendations. Intensive Care Med. 2007;33:951-962.
    • (2007) Intensive Care Med , vol.33 , pp. 951-962
    • Cheatham, M.L.1    Malbrain, M.L.2    Kirkpatrick, A.3
  • 7
    • 34249687137 scopus 로고    scopus 로고
    • ICU management of the patient with intra-abdominal hypertension: What to do, when and to whom?
    • De laet I, Malbrain ML. ICU management of the patient with intra-abdominal hypertension: what to do, when and to whom? Acta Clin Belg Suppl. 2007:190-199.
    • (2007) Acta Clin Belg Suppl , pp. 190-199
    • De Laet, I.1    Malbrain, M.L.2
  • 8
    • 0019932158 scopus 로고
    • Elevated intra-abdominal pressure and renal function
    • Harman PK, Kron IL, McLachlan HD, et al. Elevated intra-abdominal pressure and renal function. Ann Surg. 1982;196:594-597.
    • (1982) Ann Surg , vol.196 , pp. 594-597
    • Harman, P.K.1    Kron, I.L.2    McLachlan, H.D.3
  • 9
    • 34249688248 scopus 로고    scopus 로고
    • Clinical awareness of intra-abdominal hypertension and abdominal compartment syndrome in 2007
    • Kimball EJ, Kim W, Cheatham ML, et al. Clinical awareness of intra-abdominal hypertension and abdominal compartment syndrome in 2007. Acta Clin Belg Suppl. 2007:66-73.
    • (2007) Acta Clin Belg Suppl. , pp. 66-73
    • Kimball, E.J.1    Kim, W.2    Cheatham, M.L.3
  • 10
    • 0028896590 scopus 로고
    • Prospective study of intra-abdominal hypertension and renal function after laparotomy
    • Sugrue M, Buist MD, Hourihan F, et al. Prospective study of intra-abdominal hypertension and renal function after laparotomy. Br J Surg. 1995;82:235-238.
    • (1995) Br J Surg , vol.82 , pp. 235-238
    • Sugrue, M.1    Buist, M.D.2    Hourihan, F.3
  • 11
    • 59649089624 scopus 로고    scopus 로고
    • Can the abdominal perimeter be used as an accurate estimation of intra-abdominal pressure?
    • Malbrain ML, De laet I, Van Regenmortel N, et al. Can the abdominal perimeter be used as an accurate estimation of intra-abdominal pressure? Crit Care Med. 2009;37:316-319.
    • (2009) Crit Care Med , vol.37 , pp. 316-319
    • Malbrain, M.L.1    De Laet, I.2    Van Regenmortel, N.3
  • 12
    • 0036885976 scopus 로고    scopus 로고
    • Clinical examination is an inaccurate predictor of intraabdominal pressure
    • 2002
    • Sugrue M, Bauman A, Jones F, et al. Clinical examination is an inaccurate predictor of intraabdominal pressure. World J Surg. 2002;26:1428-1431, 2002.
    • (2002) World J Surg , vol.26 , pp. 1428-1431
    • Sugrue, M.1    Bauman, A.2    Jones, F.3
  • 13
    • 0032185970 scopus 로고    scopus 로고
    • Intra-abdominal pressure monitoring
    • Harrahill M. Intra-abdominal pressure monitoring. J Emerg Nurs. 1998;24: 465-466.
    • (1998) J Emerg Nurs , vol.24 , pp. 465-466
    • Harrahill, M.1
  • 14
    • 0024571532 scopus 로고
    • Determination of intra-abdominal pressure using a transurethral bladder catheter: Clinical validation of the technique
    • Iberti TJ, Lieber CE, Benjamin E. Determination of intra-abdominal pressure using a transurethral bladder catheter: clinical validation of the technique. Anesthesiology. 1989;70:47-50.
    • (1989) Anesthesiology , vol.70 , pp. 47-50
    • Iberti, T.J.1    Lieber, C.E.2    Benjamin, E.3
  • 15
    • 0036089063 scopus 로고    scopus 로고
    • A simplified approach to the diagnosis of elevated intra-abdominal pressure
    • Lee SL, Anderson JT, Kraut EJ, et al. A simplified approach to the diagnosis of elevated intra-abdominal pressure. J Trauma. 2002;52:1169-1172.
    • (2002) J Trauma , vol.52 , pp. 1169-1172
    • Lee, S.L.1    Anderson, J.T.2    Kraut, E.J.3
  • 16
    • 1642306412 scopus 로고    scopus 로고
    • Different techniques to measure intra-abdominal pressure (IAP): Time for a critical re-appraisal
    • Malbrain ML. Different techniques to measure intra-abdominal pressure (IAP): time for a critical re-appraisal. Intensive Care Med. 2004;30:357-371.
    • (2004) Intensive Care Med , vol.30 , pp. 357-371
    • Malbrain, M.L.1
  • 17
    • 43349090411 scopus 로고    scopus 로고
    • In vitro validation of a novel method for continuous intra-abdominal pressure monitoring
    • Malbrain ML, De laet I, Viaene D, et al. In vitro validation of a novel method for continuous intra-abdominal pressure monitoring. Intensive Care Med. 2008;34:740-745.
    • (2008) Intensive Care Med , vol.34 , pp. 740-745
    • Malbrain, M.L.1    De Laet, I.2    Viaene, D.3
  • 18
    • 24444447359 scopus 로고    scopus 로고
    • A novel technique of intra-abdominal pressure measurement: Validation of two prototypes
    • Malbrain ML, Léonard M, Delmarcelle D. A novel technique of intra-abdominal pressure measurement: validation of two prototypes. Crit Care. 2002;6(suppl 1):4.
    • (2002) Crit Care , vol.6 , Issue.SUPPL. 1 , pp. 4
    • Malbrain, M.L.1    Léonard, M.2    Delmarcelle, D.3
  • 19
    • 0035074506 scopus 로고    scopus 로고
    • Estimation of intra-abdominal pressure by bladder pressure measurement: Validity and methodology
    • Fusco MA, Martin RS, Chang MC. Estimation of intra-abdominal pressure by bladder pressure measurement: validity and methodology. J Trauma. 2001; 50:297-302.
    • (2001) J Trauma , vol.50 , pp. 297-302
    • Fusco, M.A.1    Martin, R.S.2    Chang, M.C.3
  • 20
    • 33845732145 scopus 로고    scopus 로고
    • Aggressive surveillance and early catheter-directed therapy in the management of intra-abdominal hypertension
    • discussion 1363-1365
    • Reed SF, Britt RC, Collins J, et al. Aggressive surveillance and early catheter-directed therapy in the management of intra-abdominal hypertension. J Trauma. 2006;61:1359-13563; discussion 1363-1365.
    • (2006) J Trauma , vol.61 , pp. 1359-13563
    • Reed, S.F.1    Britt, R.C.2    Collins, J.3
  • 21
    • 0031892505 scopus 로고    scopus 로고
    • Intraabdominal pressure: A revised method for measurement
    • DOI 10.1016/S1072-7515(98)00122-7, PII S1072751598001227
    • Cheatham ML, Safcsak K. Intraabdominal pressure: a revised method for measurement. J Am Coll Surg. 1998;186:594-595. (Pubitemid 28222084)
    • (1998) Journal of the American College of Surgeons , vol.186 , Issue.5 , pp. 594-595
    • Cheatham, M.L.1    Safcsak, K.2
  • 22
    • 0027759755 scopus 로고
    • Bedside measurement of intra-abdominal pressure (IAP) via an indwelling naso-gastric tube: Clinical validation of the technique
    • Collee GG, Lomax DM, Ferguson C, et al. Bedside measurement of intra-abdominal pressure (IAP) via an indwelling naso-gastric tube: clinical validation of the technique. Intensive Care Med. 1993;19:478-480.
    • (1993) Intensive Care Med , vol.19 , pp. 478-480
    • Collee, G.G.1    Lomax, D.M.2    Ferguson, C.3
  • 23
    • 34447133626 scopus 로고    scopus 로고
    • Semicontinuous intra-abdom-inal pressure measurement using an intragastric compliance catheter
    • De Waele JJ, Berrevoet F, Reyntjens K, et al. Semicontinuous intra-abdom-inal pressure measurement using an intragastric compliance catheter. Intensive Care Med. 2007;33:1297-1300.
    • (2007) Intensive Care Med , vol.33 , pp. 1297-1300
    • De Waele, J.J.1    Berrevoet, F.2    Reyntjens, K.3
  • 24
    • 17444432219 scopus 로고    scopus 로고
    • Fluid vs. air for semicontinuous intra-abdominal pressure measurements using a compliance catheter
    • De Waele JJ, Billiet EA, Hoste E, et al. Fluid vs. air for semicontinuous intra-abdominal pressure measurements using a compliance catheter. Intensive Care Med. 2005;31:598-599.
    • (2005) Intensive Care Med , vol.31 , pp. 598-599
    • De Waele, J.J.1    Billiet, E.A.2    Hoste, E.3
  • 25
    • 0027970030 scopus 로고
    • Intra-abdominal pressure measurement using a modified nasogastric tube: Description and validation of a new technique
    • Sugrue M, Buist MD, Lee A, et al. Intra-abdominal pressure measurement using a modified nasogastric tube: description and validation of a new technique. Intensive Care Med. 1994;20:588-590.
    • (1994) Intensive Care Med , vol.20 , pp. 588-590
    • Sugrue, M.1    Buist, M.D.2    Lee, A.3
  • 26
    • 8144220451 scopus 로고    scopus 로고
    • Measurement of bladder compliance can be standardized by a dimensionless number: Theoretical perspective
    • Wahl EF, Lerman SE, Lahdes-Vasama TT, et al. Measurement of bladder compliance can be standardized by a dimensionless number: theoretical perspective. BJU Int. 2004;94:895-897.
    • (2004) BJU Int , vol.94 , pp. 895-897
    • Wahl, E.F.1    Lerman, S.E.2    Lahdes-Vasama, T.T.3
  • 27
    • 8144226221 scopus 로고    scopus 로고
    • Measurement of bladder compliance can be standardized by a dimensionless number: Clinical perspective
    • Wahl EF, Lerman SE, Lahdes-Vasama TT, et al. Measurement of bladder compliance can be standardized by a dimensionless number: clinical perspective. BJU Int. 2004;94:898-900.
    • (2004) BJU Int , vol.94 , pp. 898-900
    • Wahl, E.F.1    Lerman, S.E.2    Lahdes-Vasama, T.T.3
  • 28
    • 0033257935 scopus 로고    scopus 로고
    • Natural pressure-volume curves and conventional cystometry
    • Klevmark B. Natural pressure-volume curves and conventional cystometry. Scand J Urol Nephrol Suppl. 1999;201:1-4.
    • (1999) Scand J Urol Nephrol Suppl , vol.201 , pp. 1-4
    • Klevmark, B.1
  • 29
    • 46149126428 scopus 로고    scopus 로고
    • The effect of different reference transducer positions on intra-abdominal pressure measurement: A multicenter analysis
    • De Waele JJ, De Laet I, De Keulenaer B, et al. The effect of different reference transducer positions on intra-abdominal pressure measurement: a multicenter analysis. Intensive Care Med. 2008;34:1299-1303.
    • (2008) Intensive Care Med , vol.34 , pp. 1299-1303
    • De Waele, J.J.1    De Laet, I.2    De Keulenaer, B.3
  • 30
    • 34247550840 scopus 로고    scopus 로고
    • 'Progression towards the minimum': The importance of standardizing the priming volume during the indirect measurement of intra-abdominal pressures
    • Ball CG, Kirkpatrick AW. 'Progression towards the minimum': the importance of standardizing the priming volume during the indirect measurement of intra-abdominal pressures. Crit Care. 2006;10:153.
    • (2006) Crit Care , vol.10 , pp. 153
    • Ball, C.G.1    Kirkpatrick, A.W.2
  • 31
    • 34548119510 scopus 로고    scopus 로고
    • The effect of different volumes and temperatures of saline on the bladder pressure measurement in critically ill patients
    • Chiumello D, Tallarini F, Chierichetti M, et al. The effect of different volumes and temperatures of saline on the bladder pressure measurement in critically ill patients. Crit Care. 2007;11:R82.
    • (2007) Crit Care , vol.11
    • Chiumello, D.1    Tallarini, F.2    Chierichetti, M.3
  • 32
    • 43349094010 scopus 로고    scopus 로고
    • Transvesical intra-abdominal pressure measurement using minimal instillation volumes: How low can we go?
    • De Laet I, Hoste E, De Waele JJ. Transvesical intra-abdominal pressure measurement using minimal instillation volumes: how low can we go? Intensive Care Med. 2008;34:746-750.
    • (2008) Intensive Care Med , vol.34 , pp. 746-750
    • De Laet, I.1    Hoste, E.2    De Waele, J.J.3
  • 33
    • 33344465726 scopus 로고    scopus 로고
    • Saline volume in transvesical intra-abdominal pressure measurement: Enough is enough
    • De Waele J, Pletinckx P, Blot S, et al. Saline volume in transvesical intra-abdominal pressure measurement: enough is enough. Intensive Care Med. 2006;32:455-459.
    • (2006) Intensive Care Med , vol.32 , pp. 455-459
    • De Waele, J.1    Pletinckx, P.2    Blot, S.3
  • 34
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 35
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15:85-91.
    • (1999) J Clin Monit Comput , vol.15 , pp. 85-91
    • Critchley, L.A.1    Critchley, J.A.2
  • 36
    • 0018079655 scopus 로고
    • Basic principles of ROC analysis
    • Metz CE. Basic principles of ROC analysis. Semin Nucl Med. 1978;8:283-298.
    • (1978) Semin Nucl Med , vol.8 , pp. 283-298
    • Metz, C.E.1
  • 37
    • 34247550878 scopus 로고    scopus 로고
    • Effect of bladder volume on measured intravesical pressure: A prospective cohort study
    • Malbrain ML, Deeren DH. Effect of bladder volume on measured intravesical pressure: a prospective cohort study. Crit Care. 2006;10:R98.
    • (2006) Crit Care , vol.10
    • Malbrain, M.L.1    Deeren, D.H.2
  • 38
    • 0016286620 scopus 로고
    • Factors predisposing to bacte-riuria during indwelling urethral catheterization
    • Garibaldi RA, Burke JP, Dickman ML, et al. Factors predisposing to bacte-riuria during indwelling urethral catheterization. N Engl J Med. 1974;291: 215-219.
    • (1974) N Engl J Med , vol.291 , pp. 215-219
    • Garibaldi, R.A.1    Burke, J.P.2    Dickman, M.L.3
  • 39
    • 0014028760 scopus 로고
    • Prevention of catheter-induced urinary-tract infections by sterile closed drainage
    • Kunin CM, McCormack RC. Prevention of catheter-induced urinary-tract infections by sterile closed drainage. N Engl J Med. 1966;274:1155-1161.
    • (1966) N Engl J Med , vol.274 , pp. 1155-1161
    • Kunin, C.M.1    McCormack, R.C.2
  • 40
    • 0021350979 scopus 로고
    • The measurement of intra-abdominal pressure as a criterion for abdominal re-exploration
    • Kron IL, Harman PK, Nolan SP. The measurement of intra-abdominal pressure as a criterion for abdominal re-exploration. Ann Surg. 1984;199:28-30.
    • (1984) Ann Surg , vol.199 , pp. 28-30
    • Kron, I.L.1    Harman, P.K.2    Nolan, S.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.