메뉴 건너뛰기




Volumn 33, Issue 6, 2009, Pages 987-990

Radiation dose to the thyroid gland and breast from multidetector computed tomography of the cervical spine: Does bismuth shielding with and without a cervical collar reduce dose?

Author keywords

Bismuth shielding; Breast; Cervical spine; CT; Dosimetry; Emergency radiology; Radiation dose; Safety

Indexed keywords

BISMUTH; COMPUTERIZED TOMOGRAPHY; IMAGE SEGMENTATION; MEDICAL IMAGING; RADIATION SHIELDING;

EID: 73949135727     PISSN: 03638715     EISSN: None     Source Type: Journal    
DOI: 10.1097/RCT.0b013e3181a776ff     Document Type: Article
Times cited : (22)

References (16)
  • 1
    • 33748986188 scopus 로고    scopus 로고
    • Increasing utilization of computed tomography in the adult emergency department, 2000-2005
    • Broder J, Warshauer DM. Increasing utilization of computed tomography in the adult emergency department, 2000-2005. Emerg Radiol. 2006;13:25-30.
    • (2006) Emerg Radiol , vol.13 , pp. 25-30
    • Broder, J.1    Warshauer, D.M.2
  • 2
    • 34548184941 scopus 로고    scopus 로고
    • Increasing utilization of computed tomography in the pediatric emergency department, 2000-2006
    • Broder J, Fordham LA, Warshauer DM. Increasing utilization of computed tomography in the pediatric emergency department, 2000-2006. Emerg Radiol. 2007;14:227-232.
    • (2007) Emerg Radiol , vol.14 , pp. 227-232
    • Broder, J.1    Fordham, L.A.2    Warshauer, D.M.3
  • 3
    • 38649099396 scopus 로고    scopus 로고
    • Computed tomography use in a tertiary care university hospital
    • Boone JM, Brunberg JA. Computed tomography use in a tertiary care university hospital. J Am Coll Radiol. 2008;5:132-138.
    • (2008) J Am Coll Radiol , vol.5 , pp. 132-138
    • Boone, J.M.1    Brunberg, J.A.2
  • 4
    • 33846197520 scopus 로고    scopus 로고
    • Radiation exposure from diagnostic imaging in severely injured trauma patients
    • Tien HC, Tremblay LN, Rizoli SB, et al. Radiation exposure from diagnostic imaging in severely injured trauma patients. J Trauma. 2007;62:151-156.
    • (2007) J Trauma , vol.62 , pp. 151-156
    • Tien, H.C.1    Tremblay, L.N.2    Rizoli, S.B.3
  • 5
    • 34147100532 scopus 로고    scopus 로고
    • Energy imparted-based estimates of the effect of z overscanning on adult and pediatric patient effective doses from multi-slice computed tomography
    • Theocharopoulos N, Damilakis J, Perisinakis K, et al. Energy imparted-based estimates of the effect of z overscanning on adult and pediatric patient effective doses from multi-slice computed tomography. Med Phys. 2007;34:1139-1152.
    • (2007) Med Phys , vol.34 , pp. 1139-1152
    • Theocharopoulos, N.1    Damilakis, J.2    Perisinakis, K.3
  • 6
    • 33845655515 scopus 로고    scopus 로고
    • Overranging in multisection CT: Quantification and relative contribution to doseVcomparison of four 16-section CT scanners
    • van der Molen AJ, Geleijns J. Overranging in multisection CT: quantification and relative contribution to doseVcomparison of four 16-section CT scanners. Radiology. 2007;242:208-216.
    • (2007) Radiology , vol.242 , pp. 208-216
    • Van Der Molen, A.J.1    Geleijns, J.2
  • 7
    • 58149271097 scopus 로고    scopus 로고
    • Radiation dose savings for adult pulmonary embolus 64-MDCT using bismuth breast shields, lower peak kilovoltage, and automatic tube current modulation
    • Hurwitz LM, Yoshizumi TT, Goodman PC, et al. Radiation dose savings for adult pulmonary embolus 64-MDCT using bismuth breast shields, lower peak kilovoltage, and automatic tube current modulation. AJR Am J Roentgenol. 2009;192:244-253.
    • (2009) AJR Am J Roentgenol , vol.192 , pp. 244-253
    • Hurwitz, L.M.1    Yoshizumi, T.T.2    Goodman, P.C.3
  • 8
    • 48949116166 scopus 로고    scopus 로고
    • Reduction of dose to the female breast in thoracic CT: A comparison of standard-protocol, bismuth-shielded, partial and tube-currentYmodulated CT examinations
    • Vollmar SV, Kalender WA. Reduction of dose to the female breast in thoracic CT: a comparison of standard-protocol, bismuth-shielded, partial and tube-currentYmodulated CT examinations. Eur Radiol. 2008;18:1674-1682.
    • (2008) Eur Radiol , vol.18 , pp. 1674-1682
    • Vollmar, S.V.1    Kalender, W.A.2
  • 9
    • 38449112969 scopus 로고    scopus 로고
    • Pediatric chest MDCT using tube current modulation: Effect on radiation dose with breast shielding
    • Coursey C, Frush DP, Yoshizumi T, et al. Pediatric chest MDCT using tube current modulation: effect on radiation dose with breast shielding. AJR Am J Roentgenol. 2008;190:W54-W61.
    • (2008) AJR Am J Roentgenol , vol.190
    • Coursey, C.1    Frush, D.P.2    Yoshizumi, T.3
  • 10
    • 33748454831 scopus 로고    scopus 로고
    • Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality
    • Geleijns J, Salvadó Artells M, Veldkamp WJ, et al. Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality. Eur Radiol. 2006;16:2334-2340.
    • (2006) Eur Radiol , vol.16 , pp. 2334-2340
    • Geleijns, J.1    Salvadó Artells, M.2    Veldkamp, W.J.3
  • 11
    • 33745700088 scopus 로고    scopus 로고
    • Radiation dose reduction to breast and thyroid during MDCT: Effectiveness of an in-plane bismuth shield
    • Hohl C, Wildberger JE, Süss C, et al. Radiation dose reduction to breast and thyroid during MDCT: effectiveness of an in-plane bismuth shield. Acta Radiol. 2006;47:562-567.
    • (2006) Acta Radiol , vol.47 , pp. 562-567
    • Hohl, C.1    Wildberger, J.E.2    Süss, C.3
  • 12
    • 33745667323 scopus 로고    scopus 로고
    • The effect of z overscanning on radiation burden of pediatric patients undergoing head CT with multidetector scanners: A Monte Carlo study
    • Tzedakis A, Perisinakis K, Raissaki M, et al. The effect of z overscanning on radiation burden of pediatric patients undergoing head CT with multidetector scanners: a Monte Carlo study. Med Phys. 2006;33:2472-2478.
    • (2006) Med Phys , vol.33 , pp. 2472-2478
    • Tzedakis, A.1    Perisinakis, K.2    Raissaki, M.3
  • 13
    • 33846634112 scopus 로고    scopus 로고
    • Female breast radiation exposure during thorax multidetector computed tomography and the effectiveness of bismuth breast shield to reduce breast radiation dose
    • Yilmaz MH, Albayram S, Yazar D, et al. Female breast radiation exposure during thorax multidetector computed tomography and the effectiveness of bismuth breast shield to reduce breast radiation dose. J Comput Assist Tomogr. 2007;31:138-142.
    • (2007) J Comput Assist Tomogr , vol.31 , pp. 138-142
    • Yilmaz, M.H.1    Albayram, S.2    Yazar, D.3
  • 14
    • 33644843754 scopus 로고    scopus 로고
    • Female breast radiation exposure during CT pulmonary angiography
    • Parker MS, Hui FK, Camacho MA, et al. Female breast radiation exposure during CT pulmonary angiography. AJR Am J Roentgenol. 2005;185:1228-1233.
    • (2005) AJR Am J Roentgenol , vol.185 , pp. 1228-1233
    • Parker, M.S.1    Hui, F.K.2    Camacho, M.A.3
  • 15
    • 33645562681 scopus 로고    scopus 로고
    • CT dose reduction and dose management tools: Overview of available options
    • McCollough CH, Bruesewitz MR, Kofler JM Jr. CT dose reduction and dose management tools: overview of available options. Radiographics. 2006;26:503-512.
    • (2006) Radiographics , vol.26 , pp. 503-512
    • McCollough, C.H.1    Bruesewitz, M.R.2    Kofler Jr., J.M.3
  • 16
    • 0345015508 scopus 로고    scopus 로고
    • Radiation dose is reduced with a single-pass whole-body multi-detector row CT trauma protocol compared with a conventional segmented method: Initial experience
    • Ptak T, Rhea JT, Novelline RA. Radiation dose is reduced with a single-pass whole-body multi-detector row CT trauma protocol compared with a conventional segmented method: initial experience. Radiology. 2003;229:902-905.
    • (2003) Radiology , vol.229 , pp. 902-905
    • Ptak, T.1    Rhea, J.T.2    Novelline, R.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.