메뉴 건너뛰기




Volumn 55, Issue 6, 2009, Pages 556-561

A passively suspended tesla pump left ventricular assist device

Author keywords

[No Author keywords available]

Indexed keywords

A-DENSITY; AXIAL DIRECTION; BLOOD PUMP; CFD MODELING; COMPUTATIONAL FLUID DYNAMICS ANALYSIS; CONTROL PURPOSE; ENDURANCE TESTING; HEAD RISE; IN-VIVO; INLET PRESSURES; LEFT VENTRICULAR ASSIST DEVICES; MAGNETIC FORCE; NORMALIZED INDEX OF HEMOLYSIS; PROTOTYPE DEVICES; RADIAL DIRECTION; REVOLUTIONS PER MINUTES; TEST RESULTS;

EID: 73949108423     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/MAT.0b013e3181bae73e     Document Type: Article
Times cited : (30)

References (16)
  • 2
    • 75149176334 scopus 로고
    • Mechanical devices to assist the failing heart, an application of the Tesla viscous flow turbine to pumping blood
    • Paper presented at National Academy of Sciences, National Research Council. Washington, DC
    • Dorman FD, Murphy TE, Blackshear PL: Mechanical devices to assist the failing heart, an application of the Tesla viscous flow turbine to pumping blood. Paper presented at The Committee on Trauma, Division of Medical Sciences, National Academy of Sciences, National Research Council. Washington, DC, 1966.
    • (1966) The Committee on Trauma, Division of Medical Sciences
    • Dorman, F.D.1    Murphy, T.E.2    Blackshear, P.L.3
  • 3
    • 0027255509 scopus 로고
    • Evaluation of a multiple disk centrifugal pump as an artificial ventricle
    • Miller GE, Sidhu A, Fink R, et al: Evaluation of a multiple disk centrifugal pump as an artificial ventricle. Artif Organs 17: 590-592, 1993.
    • (1993) Artif Organs , vol.17 , pp. 590-592
    • Miller, G.E.1    Sidhu, A.2    Fink, R.3
  • 4
    • 0032975732 scopus 로고    scopus 로고
    • Analysis of optimal design configurations for a multiple disk centrifugal blood pump
    • Miller GE, Fink R: Analysis of optimal design configurations for a multiple disk centrifugal blood pump. Artif Organs 23: 559-565, 1999.
    • (1999) Artif Organs , vol.23 , pp. 559-565
    • Miller, G.E.1    Fink, R.2
  • 5
    • 0025388827 scopus 로고
    • A multiple disk centrifugal pump as a blood flow device
    • Miller GE, Etter BD, Dorsi JM: A multiple disk centrifugal pump as a blood flow device. IEEE Trans Biomed Eng 37: 157-163, 1990.
    • (1990) IEEE Trans Biomed Eng , vol.37 , pp. 157-163
    • Miller, G.E.1    Etter, B.D.2    Dorsi, J.M.3
  • 9
    • 79957444349 scopus 로고
    • Tesla turbomachinery
    • Paper Presented at Belgrade, Yugoslavia, September
    • Rice W: Tesla turbomachinery. Paper Presented at IV International Nikola Tesla Symposium. Belgrade, Yugoslavia, September 23-25, 1991.
    • (1991) IV International Nikola Tesla Symposium , pp. 23-25
    • Rice, W.1
  • 10
    • 0000792996 scopus 로고
    • Artificial heart II- Application of nonpulsatile radially increasing pressure gradient pumping principle
    • Rafferty E, Kietschka H, Wynyard M, et al: Artificial heart II- Application of nonpulsatile radially increasing pressure gradient pumping principle. Minn Med 52: 191, 1968.
    • (1968) Minn Med , vol.52 , pp. 191
    • Rafferty, E.1    Kietschka, H.2    Wynyard, M.3
  • 11
    • 75149126405 scopus 로고    scopus 로고
    • Development of a pressure sensing device for a left ventricular assist device
    • Fritz BP, Weiss W, Cysyk J, et al: Development of a pressure sensing device for a left ventricular assist device. ASAIO J 55: 167, 2009.
    • (2009) ASAIO J , vol.55 , pp. 167
    • Fritz, B.P.1    Weiss, W.2    Cysyk, J.3
  • 12
    • 0032170498 scopus 로고    scopus 로고
    • Induction of ventricular collapse by an axial flow blood pump
    • Amin DV, Antaki JF, Litwak P, et al: Induction of ventricular collapse by an axial flow blood pump. ASAIO J 44: 685-690, 1998.
    • (1998) ASAIO J , vol.44 , pp. 685-690
    • Amin, D.V.1    Antaki, J.F.2    Litwak, P.3
  • 13
    • 0012185027 scopus 로고    scopus 로고
    • Standard practice for assessment of hemolysis in continuous flow blood pumps
    • American Society for Testing and Materials (ASTM): F 1841-97
    • American Society for Testing and Materials (ASTM): F 1841-97. Standard practice for assessment of hemolysis in continuous flow blood pumps. Vol.13.01. Annual Book ASTM Standards. 1288-1292, 1997.
    • (1997) Annual Book ASTM Standards , vol.13 , pp. 1288-1292
  • 14
    • 84948390620 scopus 로고    scopus 로고
    • The effect of pump rate and filling on hemolysis in a pulsatile left ventricular assist device
    • Paper Presented at Philadelphia, PA
    • Lukic B, Weiss WJ: The effect of pump rate and filling on hemolysis in a pulsatile left ventricular assist device. Paper Presented at IEEE 28th Annual Northeast Bioengineering Conference. Philadelphia, PA, 2002.
    • (2002) IEEE 28th Annual Northeast Bioengineering Conference
    • Lukic, B.1    Weiss, W.J.2
  • 15
    • 0000022946 scopus 로고
    • Spectrophotometric studies on blood serum and plasma; The physical determination of hemoglobin and bilirubin
    • Shinowara GY: Spectrophotometric studies on blood serum and plasma; the physical determination of hemoglobin and bilirubin. Am J Clin Pathol 24: 696-710, 1954.
    • (1954) Am J Clin Pathol , vol.24 , pp. 696-710
    • Shinowara, G.Y.1
  • 16
    • 0028009857 scopus 로고
    • The need for standardizing the index of hemolysis
    • Naito K, Mizuguchi K, Nose Y: The need for standardizing the index of hemolysis. Artif Organs 18: 7-10, 1994.
    • (1994) Artif Organs , vol.18 , pp. 7-10
    • Naito, K.1    Mizuguchi, K.2    Nose, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.