메뉴 건너뛰기




Volumn 30, Issue 1-2, 2008, Pages 23-32

Scratching mechanisms of hip artificial joints

Author keywords

Embedded particle; Total hip prostheses; Wear

Indexed keywords

ACETABULAR CUP; ARTIFICIAL JOINT; DAMAGING MECHANISM; EMBEDDED PARTICLE; EMBEDDED PARTICLES; FEMORAL HEADS; SCRATCHING MECHANISM; UHMW-PE; WEAR MECHANISMS;

EID: 73949100881     PISSN: 03548996     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (8)
  • 1
    • 10444263795 scopus 로고    scopus 로고
    • Identification of scratch mechanisms on a retrieved metallic femoral head
    • Najjar D, Bigerelle M, Migaud H.,Iost A. .Identification of scratch mechanisms on a retrieved metallic femoral head ., Wear 258 (2005),240-250.
    • (2005) Wear , vol.258 , pp. 240-250
    • Najjar, D.1    Bigerelle, M.2    Migaud, H.3    Iost, A.4
  • 4
    • 0035361147 scopus 로고    scopus 로고
    • The quantitative assessment of UHMWPE wear debris produced in hip simulator testing; The influence of head material and roughness , motion and loading
    • Elfick A.P.D.,.Smith S.L., Green S.M., Unsworth A.,.The quantitative assessment of UHMWPE wear debris produced in hip simulator testing; the influence of head material and roughness , motion and loading . ,Wear 249 (2001), 517-527
    • (2001) Wear , vol.249 , pp. 517-527
    • Elfick, A.P.D.1    Smith, S.L.2    Green, S.M.3    Unsworth, A.4
  • 5
    • 0036960511 scopus 로고    scopus 로고
    • Local head roughening as a factor contributing to variability of total hip wear; A finite element abalysis
    • Brown T.D., Stewart K.J.,.Nieman J.C,PedersenD.R., Callaghan.,.Local head roughening as a factor contributing to variability of total hip wear; a finite element abalysis., J.Biomech. Eng.124 (2002),691-698
    • (2002) J.Biomech. Eng. , vol.124 , pp. 691-698
    • Brown, T.D.1    Stewart, K.J.2    Nieman, J.C.3    Pedersen, D.R.4    Callagha, N.5
  • 6
    • 0034270534 scopus 로고    scopus 로고
    • Influence of a foreign body on the wear of mrtallic femoral heads and polyethylene acetabular cups of total hip prostheses
    • Najjar D., Behnamghader A., Iost A.,Migaud H.,.Influence of a foreign body on the wear of mrtallic femoral heads and polyethylene acetabular cups of total hip prostheses. J.Mater.Sci.Mater.Med.35(2000), 4583-4588
    • (2000) J.Mater.Sci.Mater.Med. , vol.35 , pp. 4583-4588
    • Najjar, D.1    Behnamghader, A.2    Iost, A.3    Migaud, H.4
  • 7
    • 0034984126 scopus 로고    scopus 로고
    • Hip contact force and gait patterns from routine activities
    • Bergmann G, Deuretzbacher G et.al., . Hip contact force and gait patterns from routine activities . J. Biomech. Eng.,34 (2001), 859-871
    • (2001) J. Biomech. Eng. , vol.34 , pp. 859-871
    • Bergmann, G.1    Deuretzbacher, G.2
  • 8
    • 76649089244 scopus 로고    scopus 로고
    • The orthopaedical endoprostheses durability
    • Bucharest, (in Romanian)
    • Capitanu L. .The orthopaedical endoprostheses durability., BREN , Bucharest, 2004 (in Romanian)
    • (2004) BREN
    • Capitanu, L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.