Volumn 25, Issue 1, 2010, Pages 27-34

Online signal injection through a bus-referenced current transformer

Author keywords

Condition based monitoring; Current transformers; Online diagnostics; Power system measurements; Power transformer testing; Signal generators; Test equipment

Indexed keywords

CONDITION-BASED MONITORING; CURRENT TRANSFORMER; ON-LINE DIAGNOSTICS; POWER SYSTEM MEASUREMENT; POWER TRANSFORMER TESTING; TEST EQUIPMENTS;

EID: 73849123836     PISSN: 08858977     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRD.2009.2035220     Document Type: Article
Times cited : (11)

References (17)
  • 1
    • 63049126138 scopus 로고    scopus 로고
    • Asset management of large transformers
    • Ljubljana, Slovenia, Aug. 27-31
    • R. Fischer, "Asset management of large transformers," in 15th International Symposium on High-Voltage Engineering, Ljubljana, Slovenia, Aug. 27-31, 2007, no. T6-269, pp. 1-6.
    • (2007) 15th International Symposium on High-voltage Engineering , vol.T6-269 , pp. 1-6
    • Fischer, R.1
  • 2
    • 0018038144 scopus 로고
    • Transformer diagnostic testing by frequency response analysis
    • Nov.
    • E. P. Dick and C. C. Erven, "Transformer diagnostic testing by frequency response analysis," IEEE Trans. Power App. Syst., vol. PAS-97, no. 6, pp. 2144-2153, Nov. 1978.
    • (1978) IEEE Trans. Power App. Syst. , vol.PAS-97 , Issue.6 , pp. 2144-2153
    • Dick, E.P.1    Erven, C.C.2
  • 4
    • 63049119114 scopus 로고    scopus 로고
    • Non-invasive diagnostics of transformer windings by characteristic impedance measurement
    • Ljubljana, Slovenia, Aug. 27-31
    • A. Singh, Q. Jiang, J. Martí, and K. Srivastava, "Non-invasive diagnostics of transformer windings by characteristic impedance measurement," in Proc. 15th Int. Symp. High-Voltage Engineering, Ljubljana, Slovenia, Aug. 27-31, 2007, no. T7-48, pp. 1-5.
    • (2007) Proc. 15th Int. Symp. High-voltage Engineering , vol.T7-48 , pp. 1-5
    • Singh, A.1    Jiang, Q.2    Martí, J.3    Srivastava, K.4
  • 5
    • 48749124282 scopus 로고    scopus 로고
    • Field validation tests of the TLD box for online power transformer winding monitoring systems
    • Vancouver, BC, Canada, Apr., 8.3
    • A. Singh, T. De Rybel, J. Martí, and K. Srivastava, "Field validation tests of the TLD box for online power transformer winding monitoring systems," in Proc. IEEE Canadian Conf. Electrical and Computer Engineering, Vancouver, BC, Canada, Apr. 2007, no. 8.3, pp. 1-4.
    • (2007) Proc. IEEE Canadian Conf. Electrical and Computer Engineering , pp. 1-4
    • Singh, A.1    De Rybel, T.2    Martí, J.3    Srivastava, K.4
  • 6
    • 0034505349 scopus 로고    scopus 로고
    • On the development of transfer function method for fault identification in large power transformers on load
    • Victoria, BC, Canada, Oct. 15-18
    • N. Pinhas, S. Islam, and J. Hullett, "On the development of transfer function method for fault identification in large power transformers on load," in Proc. Conf. Electrical Insulation and Dielectric Phenomena, Victoria, BC, Canada, Oct. 15-18, 2000, vol. 2, pp. 747-751.
    • (2000) Proc. Conf. Electrical Insulation and Dielectric Phenomena , vol.2 , pp. 747-751
    • Pinhas, N.1    Islam, S.2    Hullett, J.3
  • 9
    • 34848886854 scopus 로고    scopus 로고
    • Ac impedance measurement by line-to-line injected current
    • Tampa, FL, Oct. 8-12
    • J. Huang and K. Corzine, "Ac impedance measurement by line-to-line injected current," in Proc. IEEE 41st Industry Applications Conf. Annu. Meet., Tampa, FL, Oct. 8-12, 2006, vol. 1, pp. 300-306.
    • (2006) Proc. IEEE 41st Industry Applications Conf. Annu. Meet. , vol.1 , pp. 300-306
    • Huang, J.1    Corzine, K.2
  • 10
    • 0347522031 scopus 로고    scopus 로고
    • Condition monitoring of transformers in service by the low voltage impulse test method
    • London, U.K. Aug., IEE, Conf. Publ. No. 467
    • M. Wang, J. Vandermaar, and K. Srivastava, "Condition monitoring of transformers in service by the low voltage impulse test method," in Proc. 11th Int. Symp. High Voltage Engineering, London, U.K., Aug. 1999, vol. 1, IEE, pp. 45-48, Conf. Publ. No. 467.
    • (1999) Proc. 11th Int. Symp. High Voltage Engineering , vol.1 , pp. 45-48
    • Wang, M.1    Vandermaar, J.2    Srivastava, K.3
  • 11
    • 0002785928 scopus 로고    scopus 로고
    • Off/on-line FRA condition monitoring technique for power transformer
    • Aug.
    • S. Birlasekaran and F. Fetherston, "Off/on-line FRA condition monitoring technique for power transformer," IEEE Power Engineering Rev., vol. 19, no. 8, pp. 54-56, Aug. 1999.
    • (1999) IEEE Power Engineering Rev. , vol.19 , Issue.8 , pp. 54-56
    • Birlasekaran, S.1    Fetherston, F.2
  • 13
    • 0030869859 scopus 로고    scopus 로고
    • Current transformers and coupling-capacitor voltage transformers in real-time simulations
    • J. Martí, L. Linares, and H. Dommel, "Current transformers and coupling-capacitor voltage transformers in real-time simulations," IEEE Trans. Power Del., vol. 12, no. 1, pp. 164-168, Jan. 1997. (Pubitemid 127827577)
    • (1997) IEEE Transactions on Power Delivery , vol.12 , Issue.1 , pp. 164-168
    • Marti, J.R.1    Linares, L.R.2    Dommel, H.W.3
  • 14
    • 0003571556 scopus 로고
    • ser. Elect. Eng. Electron. M. O. Thurston and W. Middendorf, Eds. 2nd ed. New York: Marcel Dekker
    • C. W. T. McLyman, Transformer and Inductor Design Handbook, ser. Elect. Eng. Electron., M. O. Thurston and W. Middendorf, Eds., 2nd ed. New York: Marcel Dekker, 1988.
    • (1988) Transformer and Inductor Design Handbook
    • McLyman, C.W.T.1
  • 15


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.