메뉴 건너뛰기




Volumn 37, Issue 1, 2010, Pages 40-48

Method for evaluating bow tie filter angle-dependent attenuation in CT: Theory and simulation results

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL SIGNAL PROCESSING; COMPUTERIZED TOMOGRAPHY; DATA HANDLING; MATCHED FILTERS; MONTE CARLO METHODS; POLYMETHYL METHACRYLATES; SCANNING;

EID: 73649137857     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3264616     Document Type: Article
Times cited : (67)

References (6)
  • 1
    • 25644442569 scopus 로고    scopus 로고
    • Measurement of CT radiation profile width using CR imaging plates
    • DOI 10.1118/1.1954907
    • H. L. Liu, R. R. Liu, D. M. Reeve, S. J. Shepard, and C. E. Willis, " Measurement of CT radiation profile width using CR imaging plates.," Med. Phys. 32, 2881-2887 (2005). 10.1118/1.1954907 (Pubitemid 41384085)
    • (2005) Medical Physics , vol.32 , Issue.9 , pp. 2881-2887
    • Liu, H.-L.1    Liu, R.R.2    Reeve, D.M.3    Shepard, S.J.4    Willis, C.E.5
  • 2
    • 38349099222 scopus 로고    scopus 로고
    • CT dosimetry: Comparison of measurement techniques and devices
    • 10.1148/rg.281075024
    • J. A. Bauhs, T. J. Vrieze, A. N. Primak, M. R. Bruesewitz, and C. H. McCollough, " CT dosimetry: Comparison of measurement techniques and devices.," Radiographics 28, 245-253 (2008). 10.1148/rg.281075024
    • (2008) Radiographics , vol.28 , pp. 245-253
    • Bauhs, J.A.1    Vrieze, T.J.2    Primak, A.N.3    Bruesewitz, M.R.4    McCollough, C.H.5
  • 3
    • 0019389495 scopus 로고
    • Generalized image combinations in dual KVP digital radiography
    • DOI 10.1118/1.595025
    • L. A. Lehmann, R. E. Alvarez, A. Macovski, W. R. Brody, N. J. Pelc, S. J. Riederer, and A. L. Hall, " Generalized image combinations in dual KVP digital radiography.," Med. Phys. 8, 659-667 (1981). 10.1118/1.595025 (Pubitemid 11004040)
    • (1981) Medical Physics , vol.8 , Issue.5 , pp. 659-667
    • Lehmann, L.A.1    Alvarez, R.E.2    Macovski, A.3
  • 4
    • 0030657556 scopus 로고    scopus 로고
    • An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV
    • DOI 10.1118/1.597953
    • J. M. Boone and J. A. Seibert, " An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV.," Med. Phys. 24, 1661-1670 (1997). 10.1118/1.597953 (Pubitemid 27495900)
    • (1997) Medical Physics , vol.24 , Issue.11 , pp. 1661-1670
    • Boone, J.M.1    Seibert, J.A.2
  • 5
    • 33644681169 scopus 로고    scopus 로고
    • A simple method for evaluation of half-value layer variation in CT equipment
    • DOI 10.1088/0031-9155/51/6/016, PII S0031915506039170
    • A. F. Maia and L. V. Caldas, " A simple method for evaluation of half-value layer variation in CT equipment.," Phys. Med. Biol. 51, 1595-1601 (2006). 10.1088/0031-9155/51/6/016 (Pubitemid 43332357)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.6 , pp. 1595-1601
    • Maia, A.F.1    Caldas, L.V.E.2
  • 6
    • 0030442807 scopus 로고    scopus 로고
    • Comparison of x-ray cross sections for diagnostic and therapeutic medical physics
    • DOI 10.1118/1.597899
    • J. M. Boone and A. E. Chavez, " Comparison of x-ray cross sections for diagnostic and therapeutic medical physics.," Med. Phys. 23, 1997-2005 (1996). 10.1118/1.597899 (Pubitemid 27023697)
    • (1996) Medical Physics , vol.23 , Issue.12 , pp. 1997-2005
    • Boone, J.M.1    Chavez, A.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.