-
2
-
-
16544390243
-
Clinical examination, endosonography, and MR imaging in preoperative assessment of fistula in ano: Comparison with outcome-based reference standard
-
Buchanan GN, Halligan S, Bartram CI, Williams AB, Tarroni D, Cohen CR. Clinical examination, endosonography, and MR imaging in preoperative assessment of fistula in ano: comparison with outcome-based reference standard. Radiology 2004; 233: 674-681
-
(2004)
Radiology
, vol.233
, pp. 674-681
-
-
Buchanan, G.N.1
Halligan, S.2
Bartram, C.I.3
Williams, A.B.4
Tarroni, D.5
Cohen, C.R.6
-
3
-
-
0025801176
-
Comparison between anal endosonography and digital examination in the evaluation of anal fistulae
-
Choen S, Burnett S, Bartram CI, Nicholls RJ. Comparison between anal endosonography and digital examination in the evaluation of anal fistulae. Br J Surg 1991; 78: 445-447
-
(1991)
Br J Surg
, vol.78
, pp. 445-447
-
-
Choen, S.1
Burnett, S.2
Bartram, C.I.3
Nicholls, R.J.4
-
4
-
-
0027453446
-
Anal endosonography for recurrent anal fistulas: Image enhancement with hydrogen peroxide
-
Cheong DM, Nogueras JJ, Wexner SD, Jagelman DG. Anal endosonography for recurrent anal fistulas: image enhancement with hydrogen peroxide. Dis Colon Rectum 1993; 36: 1158-1160
-
(1993)
Dis Colon Rectum
, vol.36
, pp. 1158-1160
-
-
Cheong, D.M.1
Nogueras, J.J.2
Wexner, S.D.3
Jagelman, D.G.4
-
5
-
-
10344249473
-
Hydrogen peroxide-enhanced three-dimensional endoanal ultrasonography and endoanal magnetic resonance imaging in evaluating perianal fistulas: Agreement and patient preference
-
West RL, Dwarkasing S, Felt-Bersma RJ, Schouten WR, Hop WC, Hussain SM, Kuipers EJ. Hydrogen peroxide-enhanced three-dimensional endoanal ultrasonography and endoanal magnetic resonance imaging in evaluating perianal fistulas: agreement and patient preference. Eur J Gastroenterol Hepatol 2004; 16: 1319-1324
-
(2004)
Eur J Gastroenterol Hepatol
, vol.16
, pp. 1319-1324
-
-
West, R.L.1
Dwarkasing, S.2
Felt-Bersma, R.J.3
Schouten, W.R.4
Hop, W.C.5
Hussain, S.M.6
Kuipers, E.J.7
-
7
-
-
0032912833
-
Endosonographic criteria for an internal opening of fistula-in-ano
-
Cho DY. Endosonographic criteria for an internal opening of fistula-in-ano. Dis Colon Rectum 1999; 42: 515-518
-
(1999)
Dis Colon Rectum
, vol.42
, pp. 515-518
-
-
Cho, D.Y.1
-
8
-
-
0035490952
-
Peroxide-enhanced anal endosonography: Technique, image interpretation, and clinical applications
-
Kruskal JB, Kane RA, Morrin MM. Peroxide-enhanced anal endosonography: technique, image interpretation, and clinical applications. Radiographics 2001; 21 Spec No: S173-S189
-
(2001)
Radiographics
, Issue.21 SPEC
-
-
Kruskal, J.B.1
Kane, R.A.2
Morrin, M.M.3
-
9
-
-
0027173052
-
Intrarectal ultrasound in the evaluation of perirectal abscesses
-
Cataldo PA, Senagore A, Luchtefeld MA. Intrarectal ultrasound in the evaluation of perirectal abscesses. Dis Colon Rectum 1993; 36: 554-558
-
(1993)
Dis Colon Rectum
, vol.36
, pp. 554-558
-
-
Cataldo, P.A.1
Senagore, A.2
Luchtefeld, M.A.3
-
10
-
-
0028266496
-
Fistulas in ano: Endoanal ultrasonographic assessment assists decision making for surgery
-
Deen KI, Williams JG, Hutchinson R, Keighley MR, Kumar D. Fistulas in ano: endoanal ultrasonographic assessment assists decision making for surgery. Gut 1994; 35: 391-394
-
(1994)
Gut
, vol.35
, pp. 391-394
-
-
Deen, K.I.1
Williams, J.G.2
Hutchinson, R.3
Keighley, M.R.4
Kumar, D.5
-
11
-
-
0030014534
-
Fistula in ano: Endoanal sonography versus endoanal MR imaging in classification
-
Hussain SM, Stoker J, Schouten WR, Hop WC, Lameris JS. Fistula in ano: endoanal sonography versus endoanal MR imaging in classification. Radiology 1996; 200: 475-481
-
(1996)
Radiology
, vol.200
, pp. 475-481
-
-
Hussain, S.M.1
Stoker, J.2
Schouten, W.R.3
Hop, W.C.4
Lameris, J.S.5
-
13
-
-
0031709243
-
Hydrogen peroxide-enhanced transanal ultrasound in the assessment of fistula-in-ano
-
Poen AC, Felt-Bersma RJ, Eijsbouts QA, Cuesta MA, Meuwissen SG. Hydrogen peroxide-enhanced transanal ultrasound in the assessment of fistula-in-ano. Dis Colon Rectum 1998; 41: 1147-1152
-
(1998)
Dis Colon Rectum
, vol.41
, pp. 1147-1152
-
-
Poen, A.C.1
Felt-Bersma, R.J.2
Eijsbouts, Q.A.3
Cuesta, M.A.4
Meuwissen, S.G.5
-
14
-
-
0033623293
-
How can the assessment of fistula-inano be improved?
-
Ratto C, Gentile E, Merico M, Spinazzola C, Mangini G, Sofo L, Doglietto G. How can the assessment of fistula-inano be improved? Dis Colon Rectum 2000; 43: 1375-1382
-
(2000)
Dis Colon Rectum
, vol.43
, pp. 1375-1382
-
-
Ratto, C.1
Gentile, E.2
Merico, M.3
Spinazzola, C.4
Mangini, G.5
Sofo, L.6
Doglietto, G.7
-
15
-
-
51749125793
-
The role of three-dimensional endoluminal ultrasound imaging in the evaluation of anorectal diseases: A review
-
Gravante G, Giordano P. The role of three-dimensional endoluminal ultrasound imaging in the evaluation of anorectal diseases: a review. Surg Endosc 2008; 22: 1570-1578
-
(2008)
Surg Endosc
, vol.22
, pp. 1570-1578
-
-
Gravante, G.1
Giordano, P.2
-
16
-
-
23144452977
-
Endoanal ultrasound-guided surgery for anal fistula
-
Ratto C, Grillo E, Parello A, Costamagna G, Doglietto GB. Endoanal ultrasound-guided surgery for anal fistula. Endoscopy 2005; 37: 722-728
-
(2005)
Endoscopy
, vol.37
, pp. 722-728
-
-
Ratto, C.1
Grillo, E.2
Parello, A.3
Costamagna, G.4
Doglietto, G.B.5
-
17
-
-
13744250271
-
Value of hydrogen peroxide enhancement of three-dimensional endoanal ultrasound in fistula-in-ano
-
Buchanan GN, Bartram CI, Williams AB, Halligan S, Cohen CR. Value of hydrogen peroxide enhancement of three-dimensional endoanal ultrasound in fistula-in-ano. Dis Colon Rectum 2005; 48: 141-147
-
(2005)
Dis Colon Rectum
, vol.48
, pp. 141-147
-
-
Buchanan, G.N.1
Bartram, C.I.2
Williams, A.B.3
Halligan, S.4
Cohen, C.R.5
-
18
-
-
0142106926
-
Prospective comparison of hydrogen peroxide-enhanced three-dimensional endoanal ultrasonography and endoanal magnetic resonance imaging of perianal fistulas
-
West RL, Zimmerman DD, Dwarkasing S, Hussain SM, Hop WC, Schouten WR, Kuipers EJ, Felt-Bersma RJ. Prospective comparison of hydrogen peroxide-enhanced three-dimensional endoanal ultrasonography and endoanal magnetic resonance imaging of perianal fistulas. Dis Colon Rectum 2003; 46: 1407-1415
-
(2003)
Dis Colon Rectum
, vol.46
, pp. 1407-1415
-
-
West, R.L.1
Zimmerman, D.D.2
Dwarkasing, S.3
Hussain, S.M.4
Hop, W.C.5
Schouten, W.R.6
Kuipers, E.J.7
Felt-Bersma, R.J.8
-
19
-
-
0024380204
-
Anal endosonography in the evaluation of perianal sepsis and fistula in ano
-
Law PJ, Talbot RW, Bartram CI, Northover JM. Anal endosonography in the evaluation of perianal sepsis and fistula in ano. Br J Surg 1989; 76: 752-755
-
(1989)
Br J Surg
, vol.76
, pp. 752-755
-
-
Law, P.J.1
Talbot, R.W.2
Bartram, C.I.3
Northover, J.M.4
-
20
-
-
0022001107
-
Gas embolism produced by hydrogen peroxide irrigation of an anal fistula during anesthesia
-
Tsai SK, Lee TY, Mok MS. Gas embolism produced by hydrogen peroxide irrigation of an anal fistula during anesthesia. Anesthesiology 1985; 63: 316-317
-
(1985)
Anesthesiology
, vol.63
, pp. 316-317
-
-
Tsai, S.K.1
Lee, T.Y.2
Mok, M.S.3
-
21
-
-
0032821094
-
Gas embolism produced by hydrogen peroxide abscess irrigation in an infant
-
Schwab C, Dilworth K. Gas embolism produced by hydrogen peroxide abscess irrigation in an infant. Anaesth Intensive Care 1999; 27: 418-420
-
(1999)
Anaesth Intensive Care
, vol.27
, pp. 418-420
-
-
Schwab, C.1
Dilworth, K.2
-
22
-
-
0028321657
-
Magnetic resonance imaging of fistula-in-ano
-
Lunniss PJ, Barker PG, Sultan AH, Armstrong P, Reznek RH, Bartram CI, Cottam KS, Phillips RK. Magnetic resonance imaging of fistula-in-ano. Dis Colon Rectum 1994; 37: 708-718
-
(1994)
Dis Colon Rectum
, vol.37
, pp. 708-718
-
-
Lunniss, P.J.1
Barker, P.G.2
Sultan, A.H.3
Armstrong, P.4
Reznek, R.H.5
Bartram, C.I.6
Cottam, K.S.7
Phillips, R.K.8
-
23
-
-
0034862773
-
-
Maier AG, Funovi c s MA, Kreuzer SH, Herbst F, Wunderlich M, Teleky BK, Mittlbock M, Schima W, Lechner GL. Evaluation of perianal sepsis: comparison of anal endosonography and magnetic resonance imaging. J Magn Reson Imaging 2001; 14: 254-260
-
Maier AG, Funovi c s MA, Kreuzer SH, Herbst F, Wunderlich M, Teleky BK, Mittlbock M, Schima W, Lechner GL. Evaluation of perianal sepsis: comparison of anal endosonography and magnetic resonance imaging. J Magn Reson Imaging 2001; 14: 254-260
-
-
-
-
24
-
-
0034861965
-
Endoanal ultrasound or magnetic resonance imaging for preoperative assessment of anal fistula: A comparative study
-
Gustafsson UM, Kahvecioglu B, Astrom G, Ahlstrom H, Graf W. Endoanal ultrasound or magnetic resonance imaging for preoperative assessment of anal fistula: a comparative study. Colorectal Dis 2001; 3: 189-197
-
(2001)
Colorectal Dis
, vol.3
, pp. 189-197
-
-
Gustafsson, U.M.1
Kahvecioglu, B.2
Astrom, G.3
Ahlstrom, H.4
Graf, W.5
-
25
-
-
0034766333
-
A comparison of endoscopic ultrasound, magnetic resonance imaging, and exam under anesthesia for evaluation of Crohn's perianal fistulas
-
Schwartz DA, Wiersema MJ, Dudiak KM, Fletcher JG, Clain JE, Tremaine WJ, Zinsmeister AR, Norton ID, Boardman LA, Devine RM, Wolff BG, Young-Fadok TM, Diehl NN, Pemberton JH, Sandborn WJ. A comparison of endoscopic ultrasound, magnetic resonance imaging, and exam under anesthesia for evaluation of Crohn's perianal fistulas. Gastroenterology 2001; 121: 1064-1072
-
(2001)
Gastroenterology
, vol.121
, pp. 1064-1072
-
-
Schwartz, D.A.1
Wiersema, M.J.2
Dudiak, K.M.3
Fletcher, J.G.4
Clain, J.E.5
Tremaine, W.J.6
Zinsmeister, A.R.7
Norton, I.D.8
Boardman, L.A.9
Devine, R.M.10
Wolff, B.G.11
Young-Fadok, T.M.12
Diehl, N.N.13
Pemberton, J.H.14
Sandborn, W.J.15
-
26
-
-
0032839750
-
Use of endoanal ultrasound in patients with rectovaginal fistulas
-
Yee LF, Birnbaum EH, Read TE, Kodner IJ, Fleshman JW. Use of endoanal ultrasound in patients with rectovaginal fistulas. Dis Colon Rectum 1999; 42: 1057-1064
-
(1999)
Dis Colon Rectum
, vol.42
, pp. 1057-1064
-
-
Yee, L.F.1
Birnbaum, E.H.2
Read, T.E.3
Kodner, I.J.4
Fleshman, J.W.5
|