-
3
-
-
0035237728
-
Tilted implants as an alternative to maxillary sinus grafting: A clinical, radiologic, and periotest study
-
Aparicio C, Perales P, Rangert B. Tilted implants as an alternative to maxillary sinus grafting: A clinical, radiologic, and periotest study. Clin Implant Dent Relat Res 2001;3:39-49.
-
(2001)
Clin Implant Dent Relat Res
, vol.3
, pp. 39-49
-
-
Aparicio, C.1
Perales, P.2
Rangert, B.3
-
4
-
-
0038166666
-
Early functional loading of conical Brånemark implants in the edentulous mandible: A 12-month follow-up clinical report
-
Kronstrom M, Widbom T, Lofquist LE, Henningson C, Widbom C, Lundberg T. Early functional loading of conical Brånemark implants in the edentulous mandible: A 12-month follow-up clinical report. J Prosthet Dent 2003;89:335-340.
-
(2003)
J Prosthet Dent
, vol.89
, pp. 335-340
-
-
Kronstrom, M.1
Widbom, T.2
Lofquist, L.E.3
Henningson, C.4
Widbom, C.5
Lundberg, T.6
-
5
-
-
0043014586
-
"All-on-Four"immediate-function concept with Brånemark system implants for completely edentulous mandibles: A retrospective clinical study
-
Maló P, Rangert B, Nobre M. "All-on-Four"immediate-function concept with Brånemark system implants for completely edentulous mandibles: A retrospective clinical study. Clin Implant Dent Relat Res 2003;5(suppl 1):2-9.
-
(2003)
Clin Implant Dent Relat Res
, vol.5
, pp. 2-9
-
-
Maló, P.1
Rangert, B.2
Nobre, M.3
-
6
-
-
20744434076
-
All-on-4 immediate-function concept with Brånemark system implants for completely edentulous maxillae: A 1-year retrospective clinical study
-
Maló P, Rangert B, Nobre M. All-on-4 immediate-function concept with Brånemark system implants for completely edentulous maxillae: A 1-year retrospective clinical study. Clin Implant Dent Relat Res 2005;7(suppl 1):S88-S94.
-
(2005)
Clin Implant Dent Relat Res
, vol.7
, pp. S88-S94
-
-
Maló, P.1
Rangert, B.2
Nobre, M.3
-
7
-
-
33748290174
-
Influence of forces on peri-implant bone
-
Isidor F. Influence of forces on peri-implant bone. Clin Oral Implants Res 2006;17(suppl 2):8-18.
-
(2006)
Clin Oral Implants Res
, vol.17
, pp. 8-18
-
-
Isidor, F.1
-
8
-
-
0026488291
-
Perspectives: Bone’s mechanical usage windows
-
Frost HM. Perspectives: Bone’s mechanical usage windows. Bone Miner 1992;9:257-271.
-
(1992)
Bone Miner
, vol.9
, pp. 257-271
-
-
Frost, H.M.1
-
9
-
-
1842840921
-
A 2003 update of bone physiology and Wolff’s Law for clinicians
-
Frost HM. A 2003 update of bone physiology and Wolff’s Law for clinicians. Angle Orthod 2004;74:3-15.
-
(2004)
Angle Orthod
, vol.74
, pp. 3-15
-
-
Frost, H.M.1
-
10
-
-
0030155422
-
Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys
-
Isidor F. Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys. Clin Oral Implants Res 1996;7:143-152.
-
(1996)
Clin Oral Implants Res
, vol.7
, pp. 143-152
-
-
Isidor, F.1
-
11
-
-
0034181164
-
The influence of controlled occlusal overload on peri-implant tissue. Part 3:A histologic study in monkeys
-
Miyata T, Kobayashi Y, Araki H, Ohto T, Shin K. The influence of controlled occlusal overload on peri-implant tissue. Part 3:A histologic study in monkeys. Int J Oral Maxillofac Implants 2000;15:425-431.
-
(2000)
Int J Oral Maxillofac Implants
, vol.15
, pp. 425-431
-
-
Miyata, T.1
Kobayashi, Y.2
Araki, H.3
Ohto, T.4
Shin, K.5
-
12
-
-
18044403181
-
The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants:An animal experimental study
-
Duyck J, Ronold HJ, Van Oosterwyck H, Naert I, Vander Sloten J, Ellingsen JE. The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants:An animal experimental study. Clin Oral Implants Res 2001;12:207-218.
-
(2001)
Clin Oral Implants Res
, vol.12
, pp. 207-218
-
-
Duyck, J.1
Ronold, H.J.2
Van Oosterwyck, H.3
Naert, I.4
Vander Sloten, J.5
Ellingsen, J.E.6
-
13
-
-
0035315830
-
Biological reactions of alveolar bone to orthodontic loading of oral implants
-
Melsen B, Lang NP. Biological reactions of alveolar bone to orthodontic loading of oral implants. Clin Oral Implants Res 2001;12:144-152.
-
(2001)
Clin Oral Implants Res
, vol.12
, pp. 144-152
-
-
Melsen, B.1
Lang, N.P.2
-
14
-
-
0027015903
-
A study of 589 consecutive implants supporting complete fixed prostheses. Part II: Prosthetic aspects
-
Naert I, Quirynen M, van Steenberghe D, Darius P. A study of 589 consecutive implants supporting complete fixed prostheses. Part II: Prosthetic aspects. J Prosthet Dent 1992;68:949-956.
-
(1992)
J Prosthet Dent
, vol.68
, pp. 949-956
-
-
Naert, I.1
Quirynen, M.2
van Steenberghe, D.3
Darius, P.4
-
15
-
-
0035377362
-
Freestanding and tooth-implant connected prostheses in the treatment of partially edentulous patients Part II: An up to 15-years radiographic evaluation
-
Naert IE, Duyck JA, Hosny MM, Quirynen M, van Steenberghe D. Freestanding and tooth-implant connected prostheses in the treatment of partially edentulous patients Part II: An up to 15-years radiographic evaluation. Clin Oral Implants Res 2001;12:245-251.
-
(2001)
Clin Oral Implants Res
, vol.12
, pp. 245-251
-
-
Naert, I.E.1
Duyck, J.A.2
Hosny, M.M.3
Quirynen, M.4
van Steenberghe, D.5
-
16
-
-
0026921680
-
Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system
-
Quirynen M, Naert I, van Steenberghe D. Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system. Clin Oral Implants Res 1992;3:104-111.
-
(1992)
Clin Oral Implants Res
, vol.3
, pp. 104-111
-
-
Quirynen, M.1
Naert, I.2
van Steenberghe, D.3
-
17
-
-
0035453222
-
Effect of occlusal wear on bone loss and Periotest value of dental implants
-
Engel E, Gomez-Roman G, Axmann-Krcmar D. Effect of occlusal wear on bone loss and Periotest value of dental implants. Int J Prosthodont 2001;14:444-450.
-
(2001)
Int J Prosthodont
, vol.14
, pp. 444-450
-
-
Engel, E.1
Gomez-Roman, G.2
Axmann-Krcmar, D.3
-
18
-
-
0035502441
-
Influence of occlusal factors on treatment outcome: A study of 109 consecutive patients with mandibular implant-supported fixed prostheses opposing maxillary complete dentures
-
Wennerberg A, Carlsson GE, Jemt T. Influence of occlusal factors on treatment outcome: A study of 109 consecutive patients with mandibular implant-supported fixed prostheses opposing maxillary complete dentures. Int J Prosthodont 2001;14:550-555.
-
(2001)
Int J Prosthodont
, vol.14
, pp. 550-555
-
-
Wennerberg, A.1
Carlsson, G.E.2
Jemt, T.3
-
19
-
-
0030224418
-
Comparison of stress distribution around vertical and angled implants with finiteelement analysis
-
Canay S, Hersek N, Akpinar I, Asik Z. Comparison of stress distribution around vertical and angled implants with finiteelement analysis. Quintessence Int 1996;27:591-598.
-
(1996)
Quintessence Int
, vol.27
, pp. 591-598
-
-
Canay, S.1
Hersek, N.2
Akpinar, I.3
Asik, Z.4
-
20
-
-
16644378802
-
Photoelastic analysis of stress distribution on parallel and angled implants after installation of fixed prostheses
-
Ueda C, Markarian RA, Sendyk CL, Lagana DC. Photoelastic analysis of stress distribution on parallel and angled implants after installation of fixed prostheses. Braz Oral Res 2004;18:45-52.
-
(2004)
Braz Oral Res
, vol.18
, pp. 45-52
-
-
Ueda, C.1
Markarian, R.A.2
Sendyk, C.L.3
Lagana, D.C.4
-
21
-
-
16344386568
-
Influence of marginal bone resorption on stress around an implant-A three-dimensional finite element analysis
-
Kitamura E, Stegaroiu R, Nomura S, Miyakawa O. Influence of marginal bone resorption on stress around an implant-A three-dimensional finite element analysis. J Oral Rehabil 2005;32:279-286.
-
(2005)
J Oral Rehabil
, vol.32
, pp. 279-286
-
-
Kitamura, E.1
Stegaroiu, R.2
Nomura, S.3
Miyakawa, O.4
-
22
-
-
11444270167
-
Finite element analysis of effect of prosthesis height, angle of force application, and implant offset on supporting bone
-
Sütpideler M, Eckert SE, Zobitz M, An KN. Finite element analysis of effect of prosthesis height, angle of force application, and implant offset on supporting bone. Int J Oral Maxillofac Implants 2004;19:819-825.
-
(2004)
Int J Oral Maxillofac Implants
, vol.19
, pp. 819-825
-
-
Sütpideler, M.1
Eckert, S.E.2
Zobitz, M.3
An, K.N.4
-
23
-
-
0031088442
-
Adaptive bone remodeling around oral implants under axial and nonaxial loading conditions in the dog mandible
-
Barbier L, Schepers E. Adaptive bone remodeling around oral implants under axial and nonaxial loading conditions in the dog mandible. Int J Oral Maxillofac Implants 1997;12:215-223.
-
(1997)
Int J Oral Maxillofac Implants
, vol.12
, pp. 215-223
-
-
Barbier, L.1
Schepers, E.2
-
25
-
-
0038350018
-
The influence of functional forces on the biomechanics of implant-supported prostheses-A review
-
Sahin S, Cehreli MC, Yalcin E. The influence of functional forces on the biomechanics of implant-supported prostheses-A review. J Dent 2002;30:271-282.
-
(2002)
J Dent
, vol.30
, pp. 271-282
-
-
Sahin, S.1
Cehreli, M.C.2
Yalcin, E.3
-
26
-
-
28744456885
-
The influence of micromotion on the tissue differentiation around immediately loaded cylindrical turned titanium implants
-
Duyck J, Vandamme K, Geris L, et al. The influence of micromotion on the tissue differentiation around immediately loaded cylindrical turned titanium implants. Arch Oral Biol 2006;51:1-9.
-
(2006)
Arch Oral Biol
, vol.51
, pp. 1-9
-
-
Duyck, J.1
Vandamme, K.2
Geris, L.3
-
27
-
-
84995734831
-
-
Newark, DE: University of Delaware Department of Mechanical Engineering website, Accessed September 25
-
Mechanics of Solids [syllabus]. Newark, DE: University of Delaware Department of Mechanical Engineering website. http://www. me. udel. edu/meeg215/MEEG_215_Lab3_08. pdf:3-5. Accessed September 25, 2008.
-
(2008)
-
-
|