Mass-change sensitivity of high-order mode of piezoelectric-excited millimeter-sized cantilever (PEMC) sensors: Theory and experiments

Author keywords

6 Log dynamic range; Biosensor; Nonlinear; Resonant frequency; Simulation

Indexed keywords

6-LOG DYNAMIC RANGE; ANALYTE CONCENTRATION; CALIBRATION METHOD; DYNAMIC RANGE; EXPERIMENTAL VALUES; FINITE ELEMENT MODELS; FIRST PRINCIPLES MODELS; HIGH ORDER MODE; ORDER OF MAGNITUDE; RESONANT FREQUENCIES; SENSOR RESPONSE; WIDE DYNAMIC RANGE;

EID: 73149118920     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2009.10.019     Document Type: Article
Times cited : (40)

References (30)
  • 1
    • 34250671586 scopus 로고    scopus 로고
    • Method for measuring the self-assembly of alkanethiols on gold at femtomolar concentrations
    • Rijal K., and Mutharasan R. Method for measuring the self-assembly of alkanethiols on gold at femtomolar concentrations. Langmuir 23 (2007) 6856-6863
    • (2007) Langmuir , vol.23 , pp. 6856-6863
    • Rijal, K.1    Mutharasan, R.2
  • 2
    • 35448959959 scopus 로고    scopus 로고
    • Detection and confirmation of staphylococcal enterotoxin b in apple juice and milk using piezoelectric-excited millimeter-sized cantilever sensors at 2.5 femtograms/mL
    • Maraldo D., and Mutharasan R. Detection and confirmation of staphylococcal enterotoxin b in apple juice and milk using piezoelectric-excited millimeter-sized cantilever sensors at 2.5 femtograms/mL. Analytical Chemistry 79 (2007) 7636-7643
    • (2007) Analytical Chemistry , vol.79 , pp. 7636-7643
    • Maraldo, D.1    Mutharasan, R.2
  • 3
    • 34247120167 scopus 로고    scopus 로고
    • Method for label-free detection of femtogram quantities of biologics in flowing liquid samples
    • Maraldo D., Rijal K., Campbell G., and Mutharasan R. Method for label-free detection of femtogram quantities of biologics in flowing liquid samples. Analytical Chemistry 79 (2007) 2762-2770
    • (2007) Analytical Chemistry , vol.79 , pp. 2762-2770
    • Maraldo, D.1    Rijal, K.2    Campbell, G.3    Mutharasan, R.4
  • 4
    • 25844490050 scopus 로고    scopus 로고
    • Detection and quantification of proteins using self-excited PZT-glass millimeter-sized cantilevers
    • Campbell G.A., and Mutharasan R. Detection and quantification of proteins using self-excited PZT-glass millimeter-sized cantilevers. Biosensors and Bioelectronics 21 (2005) 597-607
    • (2005) Biosensors and Bioelectronics , vol.21 , pp. 597-607
    • Campbell, G.A.1    Mutharasan, R.2
  • 5
    • 23044511502 scopus 로고    scopus 로고
    • Detection of pathogen Escherichia coli O157:H7 using self-excited PZT-glass microcantilevers
    • Campbell G.A., and Mutharasan R. Detection of pathogen Escherichia coli O157:H7 using self-excited PZT-glass microcantilevers. Biosensors and Bioelectronics 21 (2005) 462-473
    • (2005) Biosensors and Bioelectronics , vol.21 , pp. 462-473
    • Campbell, G.A.1    Mutharasan, R.2
  • 6
    • 23444451895 scopus 로고    scopus 로고
    • Sensing of liquid level at micron resolution using self-excited millimeter-sized PZT-cantilever
    • Campbell G.A., and Mutharasan R. Sensing of liquid level at micron resolution using self-excited millimeter-sized PZT-cantilever. Sensors and Actuators A: Physical 122 (2005) 326-334
    • (2005) Sensors and Actuators A: Physical , vol.122 , pp. 326-334
    • Campbell, G.A.1    Mutharasan, R.2
  • 9
    • 0242637014 scopus 로고    scopus 로고
    • High sensitivity piezoresistive cantilever design and optimization of analyte-receptor binding
    • Yang M., Zhang X., Vafai K., and Ozkan C.S. High sensitivity piezoresistive cantilever design and optimization of analyte-receptor binding. Journal of Micromechanics and Microengineering 13 (2003) 864-872
    • (2003) Journal of Micromechanics and Microengineering , vol.13 , pp. 864-872
    • Yang, M.1    Zhang, X.2    Vafai, K.3    Ozkan, C.S.4
  • 12
    • 7544230375 scopus 로고    scopus 로고
    • Virus detection using nanoelectromechanical devices
    • Ilic B., Yang Y., and Craighead H.G. Virus detection using nanoelectromechanical devices. Applied Physics Letters 85 (2004) 2604-2606
    • (2004) Applied Physics Letters , vol.85 , pp. 2604-2606
    • Ilic, B.1    Yang, Y.2    Craighead, H.G.3
  • 13
    • 1842788500 scopus 로고    scopus 로고
    • Single virus particle mass detection using micro-resonators with nanoscale thickness
    • Gupta A., Akin D., and Bashir R. Single virus particle mass detection using micro-resonators with nanoscale thickness. Applied Physics Letters 84 (2004) 1976-1978
    • (2004) Applied Physics Letters , vol.84 , pp. 1976-1978
    • Gupta, A.1    Akin, D.2    Bashir, R.3
  • 16
    • 0032109073 scopus 로고    scopus 로고
    • Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope
    • Sader J.E. Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope. Journal of Applied Physics 84 (1998) 64-76
    • (1998) Journal of Applied Physics , vol.84 , pp. 64-76
    • Sader, J.E.1
  • 17
    • 33646889801 scopus 로고    scopus 로고
    • Use of thermally induced higher order modes of a microcantilever for mercury vapor detection
    • 094905-1-4
    • Kadam A.R., Nordin G.P., and George M.A. Use of thermally induced higher order modes of a microcantilever for mercury vapor detection. Journal of Applied Physics 99 (2006) 094905-1-4
    • (2006) Journal of Applied Physics , vol.99
    • Kadam, A.R.1    Nordin, G.P.2    George, M.A.3
  • 18
    • 19744377305 scopus 로고    scopus 로고
    • An alternative solution to improve sensitivity of resonant microcantilever chemical sensors: comparison between using high-order modes and reducing dimensions
    • Lochon F., Dufour I., and Rebiere D. An alternative solution to improve sensitivity of resonant microcantilever chemical sensors: comparison between using high-order modes and reducing dimensions. Sensors and Actuators B: Chemical 108 (2005) 979-985
    • (2005) Sensors and Actuators B: Chemical , vol.108 , pp. 979-985
    • Lochon, F.1    Dufour, I.2    Rebiere, D.3
  • 19
    • 33846986353 scopus 로고    scopus 로고
    • Method of measuring Bacillus anthracis spores in the presence of copius amounts of Bacillus thuringiensis and Bacillus cereus
    • Campbell G.A., and Mutharasan R. Method of measuring Bacillus anthracis spores in the presence of copius amounts of Bacillus thuringiensis and Bacillus cereus. Analytical Chemistry 79 (2006) 1145-1152
    • (2006) Analytical Chemistry , vol.79 , pp. 1145-1152
    • Campbell, G.A.1    Mutharasan, R.2
  • 20
    • 35448949207 scopus 로고    scopus 로고
    • Method for quantification of a prostate cancer biomarker in urine without sample preparation
    • Maraldo D., Garcia F., and Mutharasan R. Method for quantification of a prostate cancer biomarker in urine without sample preparation. Analytical Chemistry 79 (2007) 7683-7690
    • (2007) Analytical Chemistry , vol.79 , pp. 7683-7690
    • Maraldo, D.1    Garcia, F.2    Mutharasan, R.3
  • 21
    • 0942267227 scopus 로고    scopus 로고
    • An analytical model for support loss in micromachined beam resonators with in-plane flexural vibrations
    • Hao Z., Erbil A., and Ayazi F. An analytical model for support loss in micromachined beam resonators with in-plane flexural vibrations. Sensors and Actuators A: Physical 109 (2003) 156-164
    • (2003) Sensors and Actuators A: Physical , vol.109 , pp. 156-164
    • Hao, Z.1    Erbil, A.2    Ayazi, F.3
  • 22
    • 21244440321 scopus 로고    scopus 로고
    • Enhanced functionality of cantilever based mass sensors using higher order modes
    • Dohn S., Sandberg R., Svendsen W., and Boisen A. Enhanced functionality of cantilever based mass sensors using higher order modes. Applied Physics Letters 86 (2005) 233501
    • (2005) Applied Physics Letters , vol.86 , pp. 233501
    • Dohn, S.1    Sandberg, R.2    Svendsen, W.3    Boisen, A.4
  • 23
    • 0000999206 scopus 로고    scopus 로고
    • The influence of a viscous fluid on the vibration dynamics of scanning near-field optical microscopy fiber probes and atomic force microscopy cantilevers
    • Kirstein S., Mertesdorf M., and Schonhoff M. The influence of a viscous fluid on the vibration dynamics of scanning near-field optical microscopy fiber probes and atomic force microscopy cantilevers. Journal of Applied Physics 84 (1998) 1782-1790
    • (1998) Journal of Applied Physics , vol.84 , pp. 1782-1790
    • Kirstein, S.1    Mertesdorf, M.2    Schonhoff, M.3
  • 24
    • 0042313889 scopus 로고    scopus 로고
    • Exact dynamic solutions to piezoelectric smart beams including peel stresse. I. Theory and application
    • Tong L., and Luo Q. Exact dynamic solutions to piezoelectric smart beams including peel stresse. I. Theory and application. International Journal of Solids and Structures 40 (2003) 4782-4812
    • (2003) International Journal of Solids and Structures , vol.40 , pp. 4782-4812
    • Tong, L.1    Luo, Q.2
  • 26
    • 0036027562 scopus 로고    scopus 로고
    • Hydrodynamic function of polyurethane prosthetic heart valves: influences of Young's modulus and leaflet thickness
    • Bernacca G.M., O'Connor B., Williams D.F., and Wheatley D.J. Hydrodynamic function of polyurethane prosthetic heart valves: influences of Young's modulus and leaflet thickness. Biomaterials 23 (2001) 45-50
    • (2001) Biomaterials , vol.23 , pp. 45-50
    • Bernacca, G.M.1    O'Connor, B.2    Williams, D.F.3    Wheatley, D.J.4
  • 27
    • 18044398972 scopus 로고    scopus 로고
    • Self-assembled monolayers of thiolates on metals as a form of nanotechnology
    • Love J., Estroff L., Kriebel J., Nuzzo R., and Whitesides G. Self-assembled monolayers of thiolates on metals as a form of nanotechnology. Chemical Reviews 105 (2005) 1103-1169
    • (2005) Chemical Reviews , vol.105 , pp. 1103-1169
    • Love, J.1    Estroff, L.2    Kriebel, J.3    Nuzzo, R.4    Whitesides, G.5
  • 28
    • 35348982230 scopus 로고    scopus 로고
    • A method of measuring DNA hybridization at femtomolar concentration directly in human serum and in the presence of copius non-complementary strands
    • Rijal K., and Mutharasan R. A method of measuring DNA hybridization at femtomolar concentration directly in human serum and in the presence of copius non-complementary strands. Analytical Chemistry 79 (2007) 7392-7400
    • (2007) Analytical Chemistry , vol.79 , pp. 7392-7400
    • Rijal, K.1    Mutharasan, R.2
  • 29
    • 0034314223 scopus 로고    scopus 로고
    • Structure and growth of self-assembling monolayers
    • Schreiber F. Structure and growth of self-assembling monolayers. Progress in Surface Science 65 (2000) 151-257
    • (2000) Progress in Surface Science , vol.65 , pp. 151-257
    • Schreiber, F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.