메뉴 건너뛰기




Volumn 25, Issue 1, 2010, Pages 104-107

Minimum 5-Year Results in 96 Consecutive Hips Treated With a Tapered Titanium Stem System

Author keywords

5 year results; clinical outcomes; radiographic analysis; titanium stem; total hip arthroplasty

Indexed keywords

ADULT; AGED; ARTICLE; BONE REMODELING; CONTROLLED STUDY; FEMALE; FOLLOW UP; HARRIS HIP SCORE; HIP RADIOGRAPHY; HUMAN; LEG LENGTH INEQUALITY; MAJOR CLINICAL STUDY; MALE; METAL IMPLANTATION; OUTCOME ASSESSMENT; TAPERED TITANIUM STEM SYSTEM; TOTAL HIP PROSTHESIS;

EID: 73149095608     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2008.09.020     Document Type: Article
Times cited : (6)

References (24)
  • 1
    • 0038351038 scopus 로고    scopus 로고
    • Results of porous-coated anatomic total hip arthroplasty without cement at fifteen years: a concise follow-up of a previous report
    • Bojescul J.A., Xenos J.S., Callaghan J.J., et al. Results of porous-coated anatomic total hip arthroplasty without cement at fifteen years: a concise follow-up of a previous report. J Bone Joint Surg Am 85 (2003) 1079
    • (2003) J Bone Joint Surg Am , vol.85 , pp. 1079
    • Bojescul, J.A.1    Xenos, J.S.2    Callaghan, J.J.3
  • 2
    • 0031846145 scopus 로고    scopus 로고
    • A femoral component inserted without cement in total hip arthroplasty. A study of the Tri-Lock component with an average ten-year duration of follow-up
    • Burt C.F., Garvin K.L., Otterberg E.T., et al. A femoral component inserted without cement in total hip arthroplasty. A study of the Tri-Lock component with an average ten-year duration of follow-up. J Bone Joint Surg Am 80 (1998) 952
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 952
    • Burt, C.F.1    Garvin, K.L.2    Otterberg, E.T.3
  • 3
    • 0023946442 scopus 로고
    • The uncemented porous-coated anatomic total hip prosthesis. Two- year results of a prospective consecutive series
    • Callaghan J.J., Dysart S.H., and Savory C.G. The uncemented porous-coated anatomic total hip prosthesis. Two- year results of a prospective consecutive series. J Bone Joint Surg Am 70 (1988) 337
    • (1988) J Bone Joint Surg Am , vol.70 , pp. 337
    • Callaghan, J.J.1    Dysart, S.H.2    Savory, C.G.3
  • 4
    • 1842297586 scopus 로고    scopus 로고
    • Long-term results of use of the anatomic medullary locking prosthesis in total hip arthroplasty
    • Engh Jr. C.A., Culpepper II W.J., and Engh C.A. Long-term results of use of the anatomic medullary locking prosthesis in total hip arthroplasty. J Bone Joint Surg Am 79 (1997) 177
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 177
    • Engh Jr., C.A.1    Culpepper II, W.J.2    Engh, C.A.3
  • 5
    • 0029816260 scopus 로고    scopus 로고
    • Primary total hip arthroplasty with the Karl Zweymuller first-generation cementless prosthesis. A 5- to 9-year retrospective study
    • Delaunay C.P., and Kapandji A.I. Primary total hip arthroplasty with the Karl Zweymuller first-generation cementless prosthesis. A 5- to 9-year retrospective study. J Arthroplasty 11 (1996) 643
    • (1996) J Arthroplasty , vol.11 , pp. 643
    • Delaunay, C.P.1    Kapandji, A.I.2
  • 6
    • 0025179416 scopus 로고
    • Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components
    • Engh C.A., Massin P., and Suthers K.E. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res 257 (1990) 107
    • (1990) Clin Orthop Relat Res , vol.257 , pp. 107
    • Engh, C.A.1    Massin, P.2    Suthers, K.E.3
  • 7
    • 0029164470 scopus 로고
    • Comparison of cemented and cementless total hip arthroplasty in patients with bilateral hip arthroplasties
    • Hearn S.L., Bicalho P.S., Eng K., et al. Comparison of cemented and cementless total hip arthroplasty in patients with bilateral hip arthroplasties. J Arthroplasty 10 (1995) 603
    • (1995) J Arthroplasty , vol.10 , pp. 603
    • Hearn, S.L.1    Bicalho, P.S.2    Eng, K.3
  • 8
    • 0028054273 scopus 로고
    • Taperloc femoral component. A 2-6-year study of the first 100 consecutive cases
    • Hozack W., Gardiner R., Hearn S., et al. Taperloc femoral component. A 2-6-year study of the first 100 consecutive cases. J Arthroplasty 9 (1994) 489
    • (1994) J Arthroplasty , vol.9 , pp. 489
    • Hozack, W.1    Gardiner, R.2    Hearn, S.3
  • 9
    • 0141855302 scopus 로고    scopus 로고
    • Comparison of porous-coated titanium femoral stems with and without hydroxyapatite coating
    • Kim Y.H., Kim J.S., Oh S.H., et al. Comparison of porous-coated titanium femoral stems with and without hydroxyapatite coating. J Bone Joint Surg Am 85 (2003) 1682
    • (2003) J Bone Joint Surg Am , vol.85 , pp. 1682
    • Kim, Y.H.1    Kim, J.S.2    Oh, S.H.3
  • 10
    • 0030717503 scopus 로고    scopus 로고
    • Tapered design for the cementless total hip arthroplasty femoral component
    • Mallory T.H., Head W.C., and Lombardi Jr. A.V. Tapered design for the cementless total hip arthroplasty femoral component. Clin Orthop Relat Res 344 (1997) 172
    • (1997) Clin Orthop Relat Res , vol.344 , pp. 172
    • Mallory, T.H.1    Head, W.C.2    Lombardi Jr., A.V.3
  • 11
    • 0030664375 scopus 로고    scopus 로고
    • Total hip arthroplasty with an uncemented femoral component. Excellent results at ten-year follow-up
    • McLaughlin J.R., and Lee K.R. Total hip arthroplasty with an uncemented femoral component. Excellent results at ten-year follow-up. J Bone Joint Surg Br 79 (1997) 900
    • (1997) J Bone Joint Surg Br , vol.79 , pp. 900
    • McLaughlin, J.R.1    Lee, K.R.2
  • 12
    • 0034001637 scopus 로고    scopus 로고
    • Total hip arthroplasty in young patients: 8- to 13-year results using an uncemented stem
    • McLaughlin J.R., and Lee K.R. Total hip arthroplasty in young patients: 8- to 13-year results using an uncemented stem. Clin Orthop Relat Res 373 (2000) 153
    • (2000) Clin Orthop Relat Res , vol.373 , pp. 153
    • McLaughlin, J.R.1    Lee, K.R.2
  • 13
    • 0029842374 scopus 로고    scopus 로고
    • A tapered titanium femoral stem inserted without cement in a total hip arthroplasty. Radiographic evaluation and stability
    • Mulliken B.D., Bourne R.B., Rorabeck C.H., et al. A tapered titanium femoral stem inserted without cement in a total hip arthroplasty. Radiographic evaluation and stability. J Bone Joint Surg Am 78 (1996) 1214
    • (1996) J Bone Joint Surg Am , vol.78 , pp. 1214
    • Mulliken, B.D.1    Bourne, R.B.2    Rorabeck, C.H.3
  • 14
    • 0344915167 scopus 로고    scopus 로고
    • Minimum 10-year results of a tapered cementless hip replacement
    • Sakalkale D.P., Eng K., Hozack W.J., et al. Minimum 10-year results of a tapered cementless hip replacement. Clin Orthop Relat Res 362 (1999) 138
    • (1999) Clin Orthop Relat Res , vol.362 , pp. 138
    • Sakalkale, D.P.1    Eng, K.2    Hozack, W.J.3
  • 15
    • 1242319997 scopus 로고    scopus 로고
    • Primary total hip arthroplasty with an uncemented femoral component: a long-term study of the Taperloc stem
    • Parvizi J., Keisu K.S., Hozack W.J., et al. Primary total hip arthroplasty with an uncemented femoral component: a long-term study of the Taperloc stem. J Arthroplasty 19 (2004) 151
    • (2004) J Arthroplasty , vol.19 , pp. 151
    • Parvizi, J.1    Keisu, K.S.2    Hozack, W.J.3
  • 16
    • 67349132625 scopus 로고
    • Total hip replacement using APR system
    • Dorr L.D. Total hip replacement using APR system. Tech Orthop 1 (1986) 22
    • (1986) Tech Orthop , vol.1 , pp. 22
    • Dorr, L.D.1
  • 17
    • 0014525462 scopus 로고
    • Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation
    • Harris W.H. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51 (1969) 737
    • (1969) J Bone Joint Surg Am , vol.51 , pp. 737
    • Harris, W.H.1
  • 18
    • 33748420802 scopus 로고    scopus 로고
    • Favorable midterm results of total hip arthroplasties with a lateral flare uncemented stem
    • Leali A., Fetto J., and Insler H. Favorable midterm results of total hip arthroplasties with a lateral flare uncemented stem. Clin Orthop Relat Res 450 (2006) 138
    • (2006) Clin Orthop Relat Res , vol.450 , pp. 138
    • Leali, A.1    Fetto, J.2    Insler, H.3
  • 19
    • 0028123590 scopus 로고
    • Omniflex modular femoral component. Two- to five-year results
    • Capello W.N., Sallay P.I., and Feinberg J.R. Omniflex modular femoral component. Two- to five-year results. Clin Orthop Relat Res 298 (1994) 54
    • (1994) Clin Orthop Relat Res , vol.298 , pp. 54
    • Capello, W.N.1    Sallay, P.I.2    Feinberg, J.R.3
  • 20
    • 0026741611 scopus 로고
    • Early comparison of femoral components in hip arthroplasty. A preliminary study
    • Daum W.J., and Uchida T. Early comparison of femoral components in hip arthroplasty. A preliminary study. Orthop Rev 21 (1992) 327
    • (1992) Orthop Rev , vol.21 , pp. 327
    • Daum, W.J.1    Uchida, T.2
  • 21
    • 0027768291 scopus 로고
    • Total hip arthroplasty with the porous-coated anatomic (PCA) prosthesis: the femoral component
    • Van Wellen P., Demuynck M., Haentjens P., et al. Total hip arthroplasty with the porous-coated anatomic (PCA) prosthesis: the femoral component. Acta Orthop Belg 59 (1993) 282
    • (1993) Acta Orthop Belg , vol.59 , pp. 282
    • Van Wellen, P.1    Demuynck, M.2    Haentjens, P.3
  • 22
    • 0019435541 scopus 로고
    • Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man
    • Albrektsson T., Branemark P.I., Hansson H.A., et al. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand 52 (1981) 155
    • (1981) Acta Orthop Scand , vol.52 , pp. 155
    • Albrektsson, T.1    Branemark, P.I.2    Hansson, H.A.3
  • 23
    • 0019435378 scopus 로고
    • Osteogenic phenomena across endosteal bone-implant spaces with porous surfaced intramedullary implants
    • Bobyn J.D., Pilliar R.M., Cameron H.U., et al. Osteogenic phenomena across endosteal bone-implant spaces with porous surfaced intramedullary implants. Acta Orthop Scand 52 (1981) 145
    • (1981) Acta Orthop Scand , vol.52 , pp. 145
    • Bobyn, J.D.1    Pilliar, R.M.2    Cameron, H.U.3
  • 24
    • 0030671036 scopus 로고    scopus 로고
    • Hydroxyapatite coated implants. Total hip arthroplasty in the young patient and patients with avascular necrosis
    • D'Antonio J.A., Capello W.N., Manley M.T., et al. Hydroxyapatite coated implants. Total hip arthroplasty in the young patient and patients with avascular necrosis. Clin Orthop Relat Res 344 (1997) 124
    • (1997) Clin Orthop Relat Res , vol.344 , pp. 124
    • D'Antonio, J.A.1    Capello, W.N.2    Manley, M.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.