메뉴 건너뛰기




Volumn 62, Issue 6, 2009, Pages 1368-1378

Hybrid adiabatic-rectangular pulse train for effective saturation of magnetization within the whole heart at 3 T

Author keywords

Adiabatic pulse; Cardiac perfusion; Heart; MRI; SAR; Saturation

Indexed keywords

HEART; MAGNETIC RESONANCE IMAGING; SATURATION (MATERIALS COMPOSITION);

EID: 73149088849     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22140     Document Type: Article
Times cited : (21)

References (24)
  • 2
    • 0038050726 scopus 로고    scopus 로고
    • Double inversion black-blood fast spin-echo imaging of the human heart: A comparison between 1.5T and 3.0T
    • Greenman RL, Shirosky JE, Mulkern RV, Rofsky NM. Double inversion black-blood fast spin-echo imaging of the human heart: a comparison between 1.5T and 3.0T. J Magn Reson Imaging 2003;17:648-655.
    • (2003) J Magn Reson Imaging , vol.17 , pp. 648-655
    • Greenman, R.L.1    Shirosky, J.E.2    Mulkern, R.V.3    Rofsky, N.M.4
  • 4
    • 0031083035 scopus 로고    scopus 로고
    • Simulation of B1 field distribution and intrinsic signal-to-noise in cardiac MRI as a function of static magnetic field
    • Singerman RW, Denison TJ, Wen H, Balaban RS. Simulation of B1 field distribution and intrinsic signal-to-noise in cardiac MRI as a function of static magnetic field. J Magn Reson 1997;125:72-83.
    • (1997) J Magn Reson , vol.125 , pp. 72-83
    • Singerman, R.W.1    Denison, T.J.2    Wen, H.3    Balaban, R.S.4
  • 6
    • 40449084455 scopus 로고    scopus 로고
    • Measurement and characterization of RF nonuni-formity over the heart at 3T using body coil transmission
    • Sung K, Nayak KS. Measurement and characterization of RF nonuni-formity over the heart at 3T using body coil transmission. J Magn Reson Imaging 2008;27:643-648.
    • (2008) J Magn Reson Imaging , vol.27 , pp. 643-648
    • Sung, K.1    Nayak, K.S.2
  • 8
    • 28544436974 scopus 로고    scopus 로고
    • B(0) and B(1)-insensitive uniform T(1)-weighting for quantitative, first-pass myocardial perfusion magnetic resonance imaging
    • Kim D, Cernicanu A, Axel L. B(0) and B(1)-insensitive uniform T(1)-weighting for quantitative, first-pass myocardial perfusion magnetic resonance imaging. Magn Reson Med 2005;54:1423-1429.
    • (2005) Magn Reson Med , vol.54 , pp. 1423-1429
    • Kim, D.1    Cernicanu, A.2    Axel, L.3
  • 9
    • 37549070776 scopus 로고    scopus 로고
    • Comparison of the effectiveness of saturation pulses in the heart at 3T
    • Kim D, Gonen O, Oesingmann N, Axel L. Comparison of the effectiveness of saturation pulses in the heart at 3T. Magn Reson Med 2008;59: 209-215.
    • (2008) Magn Reson Med , vol.59 , pp. 209-215
    • Kim, D.1    Gonen, O.2    Oesingmann, N.3    Axel, L.4
  • 11
    • 0028434775 scopus 로고    scopus 로고
    • Ogg RJ, Kingsley PB, Taylor JS. WET, a T1- and B1-insensitive water-suppression method for in vivo localized 1H NMR spectroscopy. J Magn Reson B 1994;104:1-10.
    • Ogg RJ, Kingsley PB, Taylor JS. WET, a T1- and B1-insensitive water-suppression method for in vivo localized 1H NMR spectroscopy. J Magn Reson B 1994;104:1-10.
  • 12
    • 33947099365 scopus 로고    scopus 로고
    • Improved saturation RF pulse design for myocardial first-pass perfusion at 3T
    • Oesingmann N, Zhang Q, Simonetti O. Improved saturation RF pulse design for myocardial first-pass perfusion at 3T. J Cardiovasc Magn Reson 2004;6:373-374.
    • (2004) J Cardiovasc Magn Reson , vol.6 , pp. 373-374
    • Oesingmann, N.1    Zhang, Q.2    Simonetti, O.3
  • 13
    • 53549088080 scopus 로고    scopus 로고
    • Design and use of tailored hard-pulse trains for uniform saturation of myocardium at 3 Tesla
    • Sung K, Nayak KS. Design and use of tailored hard-pulse trains for uniform saturation of myocardium at 3 Tesla. Magn Reson Med 2008; 60:997-1002.
    • (2008) Magn Reson Med , vol.60 , pp. 997-1002
    • Sung, K.1    Nayak, K.S.2
  • 14
    • 0001722494 scopus 로고
    • B1 insensitive adiabatic RF pulses
    • Berlin: Springer-Verlag;
    • Garwood M, Ugurbil K. B1 insensitive adiabatic RF pulses. In: NMR basic principles and progress. Volume 26. Berlin: Springer-Verlag; 1992. p 109-147.
    • (1992) NMR basic principles and progress , vol.26 , pp. 109-147
    • Garwood, M.1    Ugurbil, K.2
  • 15
    • 0001271104 scopus 로고
    • Uniform sample excitation with surface coils for in vivo spectroscopy by adiabatic rapid half passage
    • Bendall M, Pegg D. Uniform sample excitation with surface coils for in vivo spectroscopy by adiabatic rapid half passage. J Magn Reson 1986; 67:376-381.
    • (1986) J Magn Reson , vol.67 , pp. 376-381
    • Bendall, M.1    Pegg, D.2
  • 16
    • 33744956872 scopus 로고    scopus 로고
    • Saturated double-angle method for rapid B1+ mapping
    • Cunningham CH, Pauly JM, Nayak KS. Saturated double-angle method for rapid B1+ mapping. Magn Reson Med 2006;55:1326-1333.
    • (2006) Magn Reson Med , vol.55 , pp. 1326-1333
    • Cunningham, C.H.1    Pauly, J.M.2    Nayak, K.S.3
  • 18
    • 0000921534 scopus 로고
    • General analytical solutions of the Bloch equations
    • Morris G, Chilvers P. General analytical solutions of the Bloch equations. J Magn Reson 1994;107:236-238.
    • (1994) J Magn Reson , vol.107 , pp. 236-238
    • Morris, G.1    Chilvers, P.2
  • 19
    • 0028339167 scopus 로고
    • Sources of intensity nonuniformity in spin echo images at 1.5 T
    • Simmons A, Tofts PS, Barker GJ, Arridge SR. Sources of intensity nonuniformity in spin echo images at 1.5 T. Magn Reson Med 1994; 32:121-128.
    • (1994) Magn Reson Med , vol.32 , pp. 121-128
    • Simmons, A.1    Tofts, P.S.2    Barker, G.J.3    Arridge, S.R.4
  • 20
    • 0035032781 scopus 로고    scopus 로고
    • Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)
    • Kellman P, Epstein FH, McVeigh ER. Adaptive sensitivity encoding incorporating temporal filtering (TSENSE). Magn Reson Med 2001;45: 846-852.
    • (2001) Magn Reson Med , vol.45 , pp. 846-852
    • Kellman, P.1    Epstein, F.H.2    McVeigh, E.R.3
  • 21
    • 33646171477 scopus 로고    scopus 로고
    • Theory-based signal calibration with single-point T1 measurements for first-pass quantitative perfusion MRI studies
    • Cernicanu A, Axel L. Theory-based signal calibration with single-point T1 measurements for first-pass quantitative perfusion MRI studies. Acad Radiol 2006;13:686-693.
    • (2006) Acad Radiol , vol.13 , pp. 686-693
    • Cernicanu, A.1    Axel, L.2
  • 22
    • 0037192118 scopus 로고    scopus 로고
    • Cerqueira MD, Weissman NJ, Dilsizian V, Jacobs AK, Kaul S, Laskey WK, Pennell DJ, Rumberger JA, Ryan T, Verani MS, American Heart Association Writing Group on Myocardial S, Registration for Cardiac I. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation 2002;105:539-542.
    • Cerqueira MD, Weissman NJ, Dilsizian V, Jacobs AK, Kaul S, Laskey WK, Pennell DJ, Rumberger JA, Ryan T, Verani MS, American Heart Association Writing Group on Myocardial S, Registration for Cardiac I. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation 2002;105:539-542.
  • 24
    • 0029112957 scopus 로고
    • Fast anatomical imaging of the heart and assessment of myocardial perfusion with arrhythmia insensitive magnetization preparation
    • Tsekos NV, Zhang Y, Merkle H, Wilke N, Jerosch-Herold M, Stillman A, Ugurbil K. Fast anatomical imaging of the heart and assessment of myocardial perfusion with arrhythmia insensitive magnetization preparation. Magn Reson Med 1995;34:530-536.
    • (1995) Magn Reson Med , vol.34 , pp. 530-536
    • Tsekos, N.V.1    Zhang, Y.2    Merkle, H.3    Wilke, N.4    Jerosch-Herold, M.5    Stillman, A.6    Ugurbil, K.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.