메뉴 건너뛰기




Volumn 17, Issue 2, 2010, Pages 201-206

Usefulness of Additional Coronary Calcium Scoring in Low-dose CT Coronary Angiography with Prospective ECG-Triggering. Impact on Total Effective Radiation Dose and Diagnostic Accuracy

Author keywords

computed tomography coronary angiography; coronary calcium scoring; diagnostic accuracy; effective radiation dose; Prospective ECG triggering

Indexed keywords

CALCIUM;

EID: 73049107330     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2009.09.007     Document Type: Article
Times cited : (27)

References (22)
  • 1
    • 33750547401 scopus 로고    scopus 로고
    • Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography
    • Hsieh J., Londt J., Vass M., et al. Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography. Med Phys 33 (2006) 4236-4248
    • (2006) Med Phys , vol.33 , pp. 4236-4248
    • Hsieh, J.1    Londt, J.2    Vass, M.3
  • 2
    • 38349134611 scopus 로고    scopus 로고
    • Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating
    • Husmann L., Valenta I., Gaemperli O., et al. Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating. Eur Heart J 29 (2008) 191-197
    • (2008) Eur Heart J , vol.29 , pp. 191-197
    • Husmann, L.1    Valenta, I.2    Gaemperli, O.3
  • 3
    • 40949165279 scopus 로고    scopus 로고
    • Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose
    • Earls J.P., Berman E.L., Urban B.A., et al. Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose. Radiology 246 (2008) 742-753
    • (2008) Radiology , vol.246 , pp. 742-753
    • Earls, J.P.1    Berman, E.L.2    Urban, B.A.3
  • 4
    • 49049116757 scopus 로고    scopus 로고
    • Prospective versus retrospective ECG gating for 64-detector CT of the coronary arteries: comparison of image quality and patient radiation dose
    • Shuman W.P., Branch K.R., May J.M., et al. Prospective versus retrospective ECG gating for 64-detector CT of the coronary arteries: comparison of image quality and patient radiation dose. Radiology 248 (2008) 431-437
    • (2008) Radiology , vol.248 , pp. 431-437
    • Shuman, W.P.1    Branch, K.R.2    May, J.M.3
  • 5
    • 49049120370 scopus 로고    scopus 로고
    • Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: assessment of image quality, stenosis, and radiation dose
    • Hirai N., Horiguchi J., Fujioka C., et al. Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: assessment of image quality, stenosis, and radiation dose. Radiology 248 (2008) 424-430
    • (2008) Radiology , vol.248 , pp. 424-430
    • Hirai, N.1    Horiguchi, J.2    Fujioka, C.3
  • 6
    • 67849126794 scopus 로고    scopus 로고
    • Determinants of vessel contrast in BMI-adapted low dose CT coronary angiography with prospective ECG-triggering
    • Herzog B.A., Husmann L., Valenta I., et al. Determinants of vessel contrast in BMI-adapted low dose CT coronary angiography with prospective ECG-triggering. Int J Cardiovasc Imaging (2009)
    • (2009) Int J Cardiovasc Imaging
    • Herzog, B.A.1    Husmann, L.2    Valenta, I.3
  • 7
    • 50249178242 scopus 로고    scopus 로고
    • Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance
    • Scheffel H., Alkadhi H., Leschka S., et al. Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance. Heart 94 (2008) 1132-1137
    • (2008) Heart , vol.94 , pp. 1132-1137
    • Scheffel, H.1    Alkadhi, H.2    Leschka, S.3
  • 8
    • 53949098971 scopus 로고    scopus 로고
    • Radiation dose reduction and coronary assessability of prospective electrocardiogram-gated computed tomography coronary angiography: comparison with retrospective electrocardiogram-gated helical scan
    • Maruyama T., Takada M., Hasuike T., et al. Radiation dose reduction and coronary assessability of prospective electrocardiogram-gated computed tomography coronary angiography: comparison with retrospective electrocardiogram-gated helical scan. J Am Coll Cardiol 52 (2008) 1450-1455
    • (2008) J Am Coll Cardiol , vol.52 , pp. 1450-1455
    • Maruyama, T.1    Takada, M.2    Hasuike, T.3
  • 9
    • 58049200697 scopus 로고    scopus 로고
    • Accuracy of low-dose computed tomography coronary angiography using prospective electrocardiogram-triggering: first clinical experience
    • Herzog B.A., Husmann L., Burkhard N., et al. Accuracy of low-dose computed tomography coronary angiography using prospective electrocardiogram-triggering: first clinical experience. Eur Heart J 29 (2008) 3037-3042
    • (2008) Eur Heart J , vol.29 , pp. 3037-3042
    • Herzog, B.A.1    Husmann, L.2    Burkhard, N.3
  • 10
    • 40649093066 scopus 로고    scopus 로고
    • Comparison of diagnostic accuracy of 64-slice computed tomography coronary angiography in patients with low, intermediate, and high cardiovascular risk
    • Husmann L., Schepis T., Scheffel H., et al. Comparison of diagnostic accuracy of 64-slice computed tomography coronary angiography in patients with low, intermediate, and high cardiovascular risk. Acad Radiol 15 (2008) 452-461
    • (2008) Acad Radiol , vol.15 , pp. 452-461
    • Husmann, L.1    Schepis, T.2    Scheffel, H.3
  • 11
    • 0035421684 scopus 로고    scopus 로고
    • Usefulness of calcium scoring using electron beam computed tomography and noninvasive coronary angiography in patients with suspected coronary artery disease
    • Leber A.W., Knez A., Mukherjee R., et al. Usefulness of calcium scoring using electron beam computed tomography and noninvasive coronary angiography in patients with suspected coronary artery disease. Am J Cardiol 88 (2001) 219-223
    • (2001) Am J Cardiol , vol.88 , pp. 219-223
    • Leber, A.W.1    Knez, A.2    Mukherjee, R.3
  • 12
    • 33846621035 scopus 로고    scopus 로고
    • Impact of coronary calcium score on diagnostic accuracy of multislice computed tomography coronary angiography for detection of coronary artery disease
    • Pundziute G., Schuijf J.D., Jukema J.W., et al. Impact of coronary calcium score on diagnostic accuracy of multislice computed tomography coronary angiography for detection of coronary artery disease. J Nucl Cardiol 14 (2007) 36-43
    • (2007) J Nucl Cardiol , vol.14 , pp. 36-43
    • Pundziute, G.1    Schuijf, J.D.2    Jukema, J.W.3
  • 13
    • 50249142446 scopus 로고    scopus 로고
    • Combining dual-source computed tomography coronary angiography and calcium scoring: added value for the assessment of coronary artery disease
    • Leschka S., Scheffel H., Desbiolles L., et al. Combining dual-source computed tomography coronary angiography and calcium scoring: added value for the assessment of coronary artery disease. Heart 94 (2008) 1154-1161
    • (2008) Heart , vol.94 , pp. 1154-1161
    • Leschka, S.1    Scheffel, H.2    Desbiolles, L.3
  • 14
    • 17644408427 scopus 로고    scopus 로고
    • Coronary artery stenoses: detection with calcium scoring, CT angiography, and both methods combined
    • Lau G.T., Ridley L.J., Schieb M.C., et al. Coronary artery stenoses: detection with calcium scoring, CT angiography, and both methods combined. Radiology 235 (2005) 415-422
    • (2005) Radiology , vol.235 , pp. 415-422
    • Lau, G.T.1    Ridley, L.J.2    Schieb, M.C.3
  • 15
    • 56749153776 scopus 로고    scopus 로고
    • Radiation risk from coronary artery disease imaging: how do different diagnostic tests compare?
    • Einstein A.J. Radiation risk from coronary artery disease imaging: how do different diagnostic tests compare?. Heart 94 (2008) 1519-1521
    • (2008) Heart , vol.94 , pp. 1519-1521
    • Einstein, A.J.1
  • 16
    • 34948895920 scopus 로고    scopus 로고
    • Radiation dose to patients from cardiac diagnostic imaging
    • Einstein A.J., Moser K.W., Thompson R.C., et al. Radiation dose to patients from cardiac diagnostic imaging. Circulation 116 (2007) 1290-1305
    • (2007) Circulation , vol.116 , pp. 1290-1305
    • Einstein, A.J.1    Moser, K.W.2    Thompson, R.C.3
  • 17
    • 0016490238 scopus 로고
    • A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association
    • Austen W.G., Edwards J.E., Frye R.L., et al. A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51 (1975) 5-40
    • (1975) Circulation , vol.51 , pp. 5-40
    • Austen, W.G.1    Edwards, J.E.2    Frye, R.L.3
  • 18
    • 33746408724 scopus 로고    scopus 로고
    • Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis
    • Garcia M.J., Lessick J., and Hoffmann M.H. Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis. JAMA 296 (2006) 403-411
    • (2006) JAMA , vol.296 , pp. 403-411
    • Garcia, M.J.1    Lessick, J.2    Hoffmann, M.H.3
  • 19
    • 41649101202 scopus 로고    scopus 로고
    • Interrelation of coronary calcification, myocardial ischemia, and outcomes in patients with intermediate likelihood of coronary artery disease: a combined positron emission tomography/computed tomography study
    • Schenker M.P., Dorbala S., Hong E.C., et al. Interrelation of coronary calcification, myocardial ischemia, and outcomes in patients with intermediate likelihood of coronary artery disease: a combined positron emission tomography/computed tomography study. Circulation 117 (2008) 1693-1700
    • (2008) Circulation , vol.117 , pp. 1693-1700
    • Schenker, M.P.1    Dorbala, S.2    Hong, E.C.3
  • 20
    • 41649095874 scopus 로고    scopus 로고
    • How low-risk is a coronary calcium score of zero? The importance of conditional probability
    • Greenland P., and Bonow R.O. How low-risk is a coronary calcium score of zero? The importance of conditional probability. Circulation 117 (2008) 1627-1629
    • (2008) Circulation , vol.117 , pp. 1627-1629
    • Greenland, P.1    Bonow, R.O.2
  • 21
    • 43449126798 scopus 로고    scopus 로고
    • Initial evaluation of coronary images from 320-detector row computed tomography
    • Rybicki F.J., Otero H.J., Steigner M.L., et al. Initial evaluation of coronary images from 320-detector row computed tomography. Int J Cardiovasc Imaging 24 (2008) 535-546
    • (2008) Int J Cardiovasc Imaging , vol.24 , pp. 535-546
    • Rybicki, F.J.1    Otero, H.J.2    Steigner, M.L.3
  • 22
    • 70449481546 scopus 로고    scopus 로고
    • Incremental prognostic value of multi-slice computed tomography coronary angiography over coronary artery calcium scoring in patients with suspected coronary artery disease
    • [Epub ahead of print]
    • van Werkhoven J.M., Schuijf J.D., Gaemperli O., et al. Incremental prognostic value of multi-slice computed tomography coronary angiography over coronary artery calcium scoring in patients with suspected coronary artery disease. Eur Heart J (2009 June 29) [Epub ahead of print]
    • (2009) Eur Heart J
    • van Werkhoven, J.M.1    Schuijf, J.D.2    Gaemperli, O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.