메뉴 건너뛰기




Volumn 12, Issue 3, 2009, Pages 150-159

Estimation of changes in dynamic hydraulic force in a magnetically suspended centrifugal blood pump with transient computational fluid dynamics analysis

Author keywords

Centrifugal pump; Computational fluid dynamics (CFD) analysis; Magnetically suspended pump; Rotary blood pump; Transient analysis

Indexed keywords

ARTICLE; BLOOD PUMP; COMPUTATIONAL FLUID DYNAMICS; COMPUTER PROGRAM; FLOW RATE; HUMAN; HYDRAULIC CONDUCTIVITY; IMPELLER; MAGNETISM; PRIORITY JOURNAL; PUMP DESIGN; STEADY STATE;

EID: 72849140159     PISSN: 14347229     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10047-009-0459-2     Document Type: Article
Times cited : (11)

References (30)
  • 1
    • 0029090222 scopus 로고
    • Model for a general mechanical blood damage prediction
    • 8572956 10.1111/j.1525-1594.1995.tb02385.x 1:STN:280:DyaK287ntV2lsQ%3D%3D
    • C. Bludszuweit 1995 Model for a general mechanical blood damage prediction Artif Organs 19 583 589 8572956 10.1111/j.1525-1594.1995.tb02385.x 1:STN:280:DyaK287ntV2lsQ%3D%3D
    • (1995) Artif Organs , vol.19 , pp. 583-589
    • Bludszuweit, C.1
  • 2
    • 0028901011 scopus 로고
    • Computational prediction of hemolysis in a centrifugal ventricular assist device
    • 7779017 10.1111/j.1525-1594.1995.tb02326.x 1:STN:280:DyaK2M3psl2nuw%3D%3D
    • M. Pinotti E.S. Rosa 1995 Computational prediction of hemolysis in a centrifugal ventricular assist device Artif Organs 19 267 273 7779017 10.1111/j.1525-1594.1995.tb02326.x 1:STN:280:DyaK2M3psl2nuw%3D%3D
    • (1995) Artif Organs , vol.19 , pp. 267-273
    • Pinotti, M.1    Rosa, E.S.2
  • 3
    • 0029086396 scopus 로고
    • Computational flow optimization of rotary blood pump components
    • 8572960 10.1111/j.1525-1594.1995.tb02389.x 1:STN:280:DyaK287ntV2ltQ%3D%3D
    • J.F. Antaki O. Ghattas G.W. Burgeen B. He 1995 Computational flow optimization of rotary blood pump components Artif Organs 19 608 615 8572960 10.1111/j.1525-1594.1995.tb02389.x 1:STN:280:DyaK287ntV2ltQ%3D%3D
    • (1995) Artif Organs , vol.19 , pp. 608-615
    • Antaki, J.F.1    Ghattas, O.2    Burgeen, G.W.3    He, B.4
  • 4
    • 0032865629 scopus 로고    scopus 로고
    • Blood flow in a continuous flow ventricular assist device
    • DOI 10.1046/j.1525-1594.1999.06420.x
    • P.E. Allaire H.G. Wood R.S. Awad D.B. Olsen 1999 Blood flow in a continuous flow ventricular assist device Artif Organs 23 769 773 10463505 10.1046/j.1525-1594.1999.06420.x 1:STN:280:DyaK1MzptFWntA%3D%3D (Pubitemid 29383322)
    • (1999) Artificial Organs , vol.23 , Issue.8 , pp. 769-773
    • Allaire, P.E.1    Wood, H.G.2    Awad, R.S.3    Olsen, D.B.4
  • 5
    • 12944288246 scopus 로고    scopus 로고
    • Numerical studies of blood shear and washing in a continuous flow ventricular assist device
    • J.B. Anderson H.G. Wood P.E. Allaire J.C. McDaniel D.B. Olsen G. Bearnson 2000 Numerical studies of blood shear and washing in a continuous flow ventricular assist device ASAIO J 46 486 494 10926152 10.1097/00002480- 200007000-00024 1:STN:280:DC%2BD3M%2Fjs1enug%3D%3D (Pubitemid 30459200)
    • (2000) ASAIO Journal , vol.46 , Issue.4 , pp. 486-494
    • Anderson, J.B.1    Wood, H.G.2    Allaire, P.E.3    Mcdaniel, J.C.4    Olsen, D.B.5    Bearnson, G.6
  • 6
    • 3142696247 scopus 로고    scopus 로고
    • Polymer electrolyte fuel cells with porous materials as fluid distributors and comparisons with tranditional channeled systems
    • DOI 10.1115/1.1738424
    • X. Song A.L. Throckmorton H.G. Wood J.F. Antaki D.B. Olsen 2004 Quantitative evaluation of blood damage in a centrifugal VAD by computational fluid dynamics Trans ASME 126 410 418 10.1115/1.1738424 (Pubitemid 38958122)
    • (2004) Journal of Heat Transfer , vol.126 , Issue.3 , pp. 410-418
    • Senn, S.M.1    Poulikakos, D.2
  • 7
    • 27744605262 scopus 로고    scopus 로고
    • Numerical and experimental analysis of an axial flow left ventricular assist device: The influence of the diffuser on overall pump performance
    • DOI 10.1111/j.1525-1594.2005.29095.x
    • A. Untaroiu A.L. Throckmorton S.M. Patel H.G. Wood P.E. Allaire D.B. Olsen 2005 Numerical and experimental analysis of an axial flow left ventricular assist device: the influence of the diffuser on overall pump performance Artif Organs 29 581 591 15982287 10.1111/j.1525-1594.2005.29095.x (Pubitemid 41602858)
    • (2005) Artificial Organs , vol.29 , Issue.7 , pp. 581-591
    • Untaroiu, A.1    Throckmorton, A.L.2    Patel, S.M.3    Wood, H.G.4    Allaire, P.E.5    Olsen, D.B.6
  • 8
    • 36549056164 scopus 로고    scopus 로고
    • Numerical design and experimental hydraulic testing of an axial flow ventricular assist device for infants and children
    • DOI 10.1097/MAT.0b013e31815581ea, PII 0000248020071100000023
    • A.L. Throckmorton A. Untaroiu P.E. Allaire H.G. Wood D.S. Lim M.A. McCulloch D.B. Olsen 2007 Numerical design and experimental hydraulic testing of an axial flow ventricular assist device for infants and children ASAIO J 53 754 761 18043161 10.1097/MAT.0b013e31815581ea (Pubitemid 350191012)
    • (2007) ASAIO Journal , vol.53 , Issue.6 , pp. 754-761
    • Throckmorton, A.L.1    Untaroiu, A.2    Allaire, P.E.3    Wood, H.G.4    Lim, D.S.5    McCulloch, M.A.6    Olsen, D.B.7
  • 9
    • 33644993283 scopus 로고    scopus 로고
    • Computational and experimental evaluation of the fluid dynamics and hemocompatibility of the CentriMag blood pump
    • 16480391 10.1111/j.1525-1594.2006.00203.x
    • J. Zhang B. Gellman A. Koert K.A. Dasse R.J. Gilbert B.P. Griffith Z.J. Wu 2006 Computational and experimental evaluation of the fluid dynamics and hemocompatibility of the CentriMag blood pump Artif Organs 30 168 177 16480391 10.1111/j.1525-1594.2006.00203.x
    • (2006) Artif Organs , vol.30 , pp. 168-177
    • Zhang, J.1    Gellman, B.2    Koert, A.3    Dasse, K.A.4    Gilbert, R.J.5    Griffith, B.P.6    Wu, Z.J.7
  • 10
    • 33846415116 scopus 로고    scopus 로고
    • Optimization of a miniature Maglev ventricular assist device for pediatric circulatory support
    • DOI 10.1097/01.mat.0000247043.18115.f7, PII 0000248020070100000005
    • J. Zhang A. Koert B. Gellman T.M. Gempp K.A. Dasse R.J. Gilbert B.P. Griffith Z.J. Wu 2007 Optimization of a miniature maglev ventricular assist device for pediatric circulatory support ASAIO J 53 23 31 17237645 10.1097/01.mat.0000247043.18115.f7 (Pubitemid 46145488)
    • (2007) ASAIO Journal , vol.53 , Issue.1 , pp. 23-31
    • Zhang, J.1    Koert, A.2    Gellman, B.3    Gempp, T.M.4    Dasse, K.A.5    Gilbert, R.J.6    Griffith, B.P.7    Wu, Z.J.8
  • 11
    • 20644438647 scopus 로고    scopus 로고
    • Numerical investigation of the effects of the clearance gap between the inducer and impeller of an axial blood pump
    • DOI 10.1111/j.1525-1594.2005.29046.x
    • W.K. Chang Y.W. Wong W. Ong S.Y. Koh V. Chong 2005 Numerical investigation of the effects of the clearance gap between the inducer and impeller of an axial blood pump Artif Organs 29 250 258 10.1111/j.1525-1594. 2005.29046.x (Pubitemid 41648027)
    • (2005) Artificial Organs , vol.29 , Issue.3 , pp. 250-258
    • Chan, W.-K.1    Wong, Y.-W.2    Ong, W.3    Koh, S.-Y.4    Chong, V.5
  • 12
    • 33644873240 scopus 로고    scopus 로고
    • Design considerations of volute geometry of a centrifugal blood pump
    • DOI 10.1111/j.1525-1594.2005.00163.x
    • W.K. Chan Y.W. Wong W. Hu 2005 Design consideration of volute geometry of a centrifugal blood pump Artif Organs 29 937 948 16305649 10.1111/j.1525-1594. 2005.00163.x (Pubitemid 43943029)
    • (2005) Artificial Organs , vol.29 , Issue.12 , pp. 937-948
    • Chan, W.K.1    Wong, Y.W.2    Hu, W.3
  • 13
    • 34547121435 scopus 로고    scopus 로고
    • Effects of tongue position and base circle diameter on the performance of a centrifugal blood pump
    • DOI 10.1111/j.1525-1594.2007.00430.x
    • Y.W. Wong W.K. Chan W. Hu 2007 Effect of tongue position and base circle diameter on the performance of a centrifugal blood pump Artif Organs 31 639 645 17651119 10.1111/j.1525-1594.2007.00430.x (Pubitemid 47101108)
    • (2007) Artificial Organs , vol.31 , Issue.8 , pp. 639-645
    • Wong, Y.-W.1    Chan, W.-K.2    Hu, W.3
  • 14
    • 33744751460 scopus 로고    scopus 로고
    • Numerical analysis of the inner flow field of a biocentrifugal blood pump
    • DOI 10.1111/j.1525-1594.2006.00243.x
    • L.P. Chua G. Song T.M. Lim T. Zhou 2006 Numerical analysis of the inner flow field of a biocentrifugal blood pump Artif Organs 30 467 477 16734599 10.1111/j.1525-1594.2006.00243.x (Pubitemid 43824193)
    • (2006) Artificial Organs , vol.30 , Issue.6 , pp. 467-477
    • Chua, L.P.1    Song, G.2    Lim, T.M.3    Zhou, T.4
  • 15
    • 33751238802 scopus 로고    scopus 로고
    • Numerical investigation on hydrodynamics and biocompatibility of a magnetically suspended axial blood pump
    • DOI 10.1097/01.mat.0000242161.50276.1e, PII 0000248020061100000003
    • X. Zhu M. Zhang G. Zhang H. Liu 2006 Numerical investigation on hydrodynamics and biocompatibility of a magnetically suspended axial blood pump ASAIO J 52 624 629 17117050 10.1097/01.mat.0000242161.50276.1e (Pubitemid 44784562)
    • (2006) ASAIO Journal , vol.52 , Issue.6 , pp. 624-629
    • Zhu, X.1    Zhang, M.2    Zhang, G.3    Liu, H.4
  • 16
    • 33646267705 scopus 로고    scopus 로고
    • Computational fluid dynamics and digital particle image velocimetry study of the flow through an optimized micro-axial blood pump
    • 16683957 10.1111/j.1525-1594.2006.00230.x
    • M. Triep C. Brucker W. Schroder T. Siess 2006 Computational fluid dynamics and digital particle image velocimetry study of the flow through an optimized micro-axial blood pump Artif Organs 30 384 391 16683957 10.1111/j.1525-1594.2006.00230.x
    • (2006) Artif Organs , vol.30 , pp. 384-391
    • Triep, M.1    Brucker, C.2    Schroder, W.3    Siess, T.4
  • 17
    • 72849134253 scopus 로고    scopus 로고
    • Computational fluid dynamics as a tool to develop the artificial heart
    • T. Yamaguchi (eds). Springer-Verlag Tokyo
    • Masuzawa T. Computational fluid dynamics as a tool to develop the artificial heart. In: Yamaguchi T (ed) Clinical application of computational mechanics to the cardiovascular system. Tokyo: Springer-Verlag, 2000;246-257
    • (2000) Clinical Application of Computational Mechanics to the Cardiovascular System , pp. 246-257
    • Masuzawa, T.1
  • 18
    • 0031922692 scopus 로고    scopus 로고
    • Computational fluid dynamic analyses to establish design process of centrifugal blood pumps
    • DOI 10.1046/j.1525-1594.1998.06169.x
    • Y. Miyazoe T. Sawairi K. Ito Y. Konishi T. Yamane M. Nishida T. Masuzawa K. Takiura Y. Taenaka 1998 Computational fluid dynamics analysis to establish the design process of a centrifugal blood pump Artif Organs 22 381 385 9609345 10.1046/j.1525-1594.1998.06169.x 1:STN:280:DyaK1c3ntVGjug%3D%3D (Pubitemid 28222296)
    • (1998) Artificial Organs , vol.22 , Issue.5 , pp. 381-385
    • Miyazoe, Y.1    Sawairi, T.2    Ito, K.3    Konishi, Y.4    Yamane, T.5    Nishida, M.6    Masuzawa, T.7    Takiura, K.8    Taenaka, Y.9
  • 19
    • 0032874351 scopus 로고    scopus 로고
    • Computational fluid dynamics analysis to establish the design process of a centrifugal blood pump: Second report
    • DOI 10.1046/j.1525-1594.1999.06418.x
    • Y. Miyazoe T. Sawairi K. Ito Y. Konishi T. Yamane M. Nishida B. Asztalos T. Mauzawa T. Tsukiya S. Endo Y. Taenaka 1999 Computational fluid dynamics analysis to establish the design process of a centrifugal blood pump: second report Artif Organs 23 762 768 10463504 10.1046/j.1525-1594.1999.06418.x 1:STN:280:DyaK1MzptFWntw%3D%3D (Pubitemid 29383321)
    • (1999) Artificial Organs , vol.23 , Issue.8 , pp. 762-768
    • Miyazoe, Y.1    Sawairi, T.2    Ito, K.3    Konishi, Y.4    Yamane, T.5    Nishida, M.6    Asztalos, B.7    Masuzawa, T.8    Tsukiya, T.9    Endo, S.10    Taenaka, Y.11
  • 20
    • 0031898596 scopus 로고    scopus 로고
    • Flow visualization as a complementary tool to hemolysis testing in the development of centrifugal blood pumps
    • DOI 10.1046/j.1525-1594.1998.06126.x
    • T. Yamane B. Asztalos M. Nishida T. Masuzawa K. Takiura Y. Taenaka Y. Konishi Y. Miyazoe K. Ito 1998 Flow visualization as a complementary tool to hemolysis testing in the development of centrifugal blood pump Artif Organs 22 375 380 9609344 10.1046/j.1525-1594.1998.06126.x 1:STN:280:DyaK1c3ntVGjtQ%3D%3D (Pubitemid 28222295)
    • (1998) Artificial Organs , vol.22 , Issue.5 , pp. 375-380
    • Yamane, T.1    Asztalos, B.2    Nishida, M.3    Masuzawa, T.4    Takiura, K.5    Taenaka, Y.6    Konishi, Y.7    Miyazoe, Y.8    Ito, K.9
  • 21
    • 0032816330 scopus 로고    scopus 로고
    • Flow visualization study to improve hemocompatibility of a centrifugal blood pump
    • DOI 10.1046/j.1525-1594.1999.06400.x
    • M. Nishida B. Asztalos T. Yamane T. Masuzawa T. Tsukiya S. Endo Y. Teanaka Y. Miyazoe K. Ito Y. Konishi 1999 Flow visualization study to improve hemocompatibility of a centrifugal blood pump Artif Organs 23 697 703 10463491 10.1046/j.1525-1594.1999.06400.x 1:STN:280:DyaK1MzptFWgsA%3D%3D (Pubitemid 29383308)
    • (1999) Artificial Organs , vol.23 , Issue.8 , pp. 697-703
    • Nishida, M.1    Asztalos, B.2    Yamane, T.3    Masuzawa, T.4    Tsukiya, T.5    Endo, S.6    Taenaka, Y.7    Miyazoe, Y.8    Ito, K.9    Konishi, Y.10
  • 22
    • 15144343373 scopus 로고    scopus 로고
    • Development of design methods of a centrifugal blood pump with in vitro tests, flow visualization, and computational fluid dynamics: Results in hemolysis tests
    • DOI 10.1046/j.1525-1594.1998.06149.x
    • K. Takiura T. Masuzawa S. Endo Y. Wakisaka E. Tatsumi Y. Taenaka H. Takano T. Yamane M. Nishida B. Asztalos Y. Konishi Y. Miyazoe K. Ito 1998 Development of design methods of a centrifugal blood pump with in vitro tests, flow visualization and computational fluid dynamics: results in hemolysis tests Artif Organs 22 393 398 9609347 10.1046/j.1525-1594.1998.06149.x 1:STN:280:DyaK1c3ntVGisg%3D%3D (Pubitemid 28222298)
    • (1998) Artificial Organs , vol.22 , Issue.5 , pp. 393-398
    • Takiura, K.1    Masuzawa, T.2    Endo, S.3    Wakisaka, Y.4    Tatsumi, E.5    Taenaka, Y.6    Takano, H.7    Yamane, T.8    Nishida, M.9    Asztalos, B.10    Konishi, Y.11    Miyazoe, Y.12    Ito, K.13
  • 24
    • 33646243597 scopus 로고    scopus 로고
    • Third-generation blood pumps with mechanical noncontact magnetic bearings
    • 16683949 10.1111/j.1525-1594.2006.00222.x
    • H. Hoshi T. Shinshi S. Takantani 2006 Third-generation blood pumps with mechanical noncontact magnetic bearings Artif Organs 30 324 338 16683949 10.1111/j.1525-1594.2006.00222.x
    • (2006) Artif Organs , vol.30 , pp. 324-338
    • Hoshi, H.1    Shinshi, T.2    Takantani, S.3
  • 25
    • 0033919463 scopus 로고    scopus 로고
    • Magnetically suspended rotary blood pump with radial type combined motor-bearing
    • DOI 10.1046/j.1525-1594.2000.06577.x
    • T. Masuzawa Y. Kita K. Matsuda Y. Okada 2000 Magnetically suspended rotary blood pump with radial type combined motor bearing Artif Organs 24 468 474 10886067 10.1046/j.1525-1594.2000.06577.x 1:STN:280:DC%2BD3cvhslSnsQ%3D%3D (Pubitemid 30430509)
    • (2000) Artificial Organs , vol.24 , Issue.6 , pp. 468-474
    • Masuzawa, T.1    Kita, T.2    Matsuda, K.-I.3    Okada, Y.4
  • 26
    • 0034823361 scopus 로고    scopus 로고
    • An ultradurable and compact rotary blood pump with a magnetically suspended impeller in the radial direction
    • DOI 10.1046/j.1525-1594.2001.025005395.x
    • T. Masuzawa Y. Kita Y. Okada 2001 An ultradurable and compact rotary blood pump with a magnetically suspended impeller in the radial direction Artif Organs 25 395 399 11403671 10.1046/j.1525-1594.2001.025005395.x 1:STN:280:DC%2BD3MzjsF2msg%3D%3D (Pubitemid 32830471)
    • (2001) Artificial Organs , vol.25 , Issue.5 , pp. 395-399
    • Masuzawa, T.1    Kita, T.2    Okada, Y.3
  • 27
    • 0036631267 scopus 로고    scopus 로고
    • Magnetically suspended centrifugal blood pump with a self-bearing motor
    • 12141477 10.1097/00002480-200207000-00019
    • T. Masuzawa H. Onuma S.J. Kim Y. Okada 2002 Magnetically suspended centrifugal blood pump with a self-bearing motor ASAIO J 48 437 442 12141477 10.1097/00002480-200207000-00019
    • (2002) ASAIO J , vol.48 , pp. 437-442
    • Masuzawa, T.1    Onuma, H.2    Kim, S.J.3    Okada, Y.4
  • 28
    • 12844251273 scopus 로고    scopus 로고
    • Novel maglev pump with a combined magnetic bearing
    • DOI 10.1097/01.MAT.0000151149.23519.19
    • H. Onuma M. Murakami T. Masuzawa 2005 Novel maglev pump with a combined magnetic bearing ASAIO J 51 50 55 15745134 10.1097/01.MAT.0000151149.23519.19 (Pubitemid 40165251)
    • (2005) ASAIO Journal , vol.51 , Issue.1 , pp. 50-55
    • Onuma, H.1    Murakami, M.2    Masuzawa, T.3
  • 29
    • 72849144187 scopus 로고    scopus 로고
    • Fluid force estimation and zero power control of the magnetically suspended centrifugal blood pump
    • 04-25, CDROM#718 (in Japanese)
    • Masuzawa T, Onuma H, Okada Y, Tsukiya T, Tatsumi E, Taenaka Y. Fluid force estimation and zero power control of the magnetically suspended centrifugal blood pump. JSME Fluid Engineering Conference 2004; No. 04-25, CDROM#718 (in Japanese)
    • (2004) JSME Fluid Engineering Conference
    • Masuzawa, T.1    Onuma, H.2    Okada, Y.3    Tsukiya, T.4    Tatsumi, E.5    Taenaka, Y.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.