메뉴 건너뛰기




Volumn 107, Issue 5, 2009, Pages 1497-1503

Discerning aortic waves during intra-aortic balloon pumping and their relation to benefits of counterpulsation in humans

Author keywords

Aortic flow; Aortic pressure; Counterpulsation; Wave intensity analysis; Waves

Indexed keywords

ADULT; AORTA BALLOON; AORTA PRESSURE; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; CORONARY HEMODYNAMICS; COUNTERPULSATION; DIASTOLIC BLOOD PRESSURE; FEMALE; FLOW RATE; HEART VENTRICLE ENDDIASTOLIC PRESSURE; HUMAN; MALE; PRIORITY JOURNAL;

EID: 72749084371     PISSN: 87507587     EISSN: 15221601     Source Type: Journal    
DOI: 10.1152/japplphysiol.00413.2009     Document Type: Article
Times cited : (33)

References (27)
  • 1
    • 0036796251 scopus 로고    scopus 로고
    • The intraaortic balloon pump in cardiac surgery
    • DOI 10.1016/S0003-4975(02)03663-9, PII S0003497502036639
    • Baskett RJ, Ghali WA, Maitland A, Hirsch GM. The intra-aortic balloon pump in cardiac surgery. Ann Thorac Surg 74: 1276-1287, 2002. (Pubitemid 35176775)
    • (2002) Annals of Thoracic Surgery , vol.74 , Issue.4 , pp. 1276-1287
    • Baskett, R.J.F.1    Ghali, W.A.2    Maitland, A.3    Hirsch, G.M.4
  • 2
    • 0038105024 scopus 로고    scopus 로고
    • Chasing the wave. Unfashionable but important new concepts in arterial wave travel
    • Bleasdale RA, Parker KH, Jones CJH. Chasing the wave. Unfashionable but important new concepts in arterial wave travel. Am J Physiol Heart Circ Physiol 284: H1879-H1885, 2003.
    • (2003) Am J Physiol Heart Circ Physiol , vol.284
    • Bleasdale, R.A.1    Parker, K.H.2    Jones, C.J.H.3
  • 7
    • 0025835055 scopus 로고
    • Intra-aortic balloon counterpulsation
    • Kern MJ. Intra-aortic balloon counterpulsation. Coron Artery Dis 2: 649-660, 1991.
    • (1991) Coron Artery Dis , vol.2 , pp. 649-660
    • Kern, M.J.1
  • 8
    • 34548742377 scopus 로고    scopus 로고
    • Pressure and flow across severe stenoses: Does the intra-aortic balloon pump do its job?
    • Kern MJ. Pressure and flow across severe stenoses: does the intra-aortic balloon pump do its job? Am Heart J 154: 615-616, 2007.
    • (2007) Am Heart J , vol.154 , pp. 615-616
    • Kern, M.J.1
  • 9
    • 0027392824 scopus 로고
    • Augmentation of coronary blood flow by intra-aortic balloon pumping in patients after coronary angioplasty
    • Kern MJ, Aguirre F, Bach R, Donohue T, Siegel R, Segal J. Augmentation of coronary blood flow by intra-aortic balloon pumping in patients after coronary angioplasty. Circulation 87: 500-511, 1993. (Pubitemid 23040920)
    • (1993) Circulation , vol.87 , Issue.2 , pp. 500-511
    • Kern, M.J.1    Aguirre, F.2    Bach, R.3    Donohue, T.4    Siegel, R.5    Segal, J.6
  • 11
    • 0034892079 scopus 로고    scopus 로고
    • Determination of wave speed and wave separation in the arteries
    • Khir AW, O'Brien AB, Gibbs JSR, Parker KH. Determination of wave speed and wave separation in the arteries. J Biomech 34: 1145-1155, 2001.
    • (2001) J Biomech , vol.34 , pp. 1145-1155
    • Khir, A.W.1    O'Brien, A.B.2    Gibbs, J.S.R.3    Parker, K.H.4
  • 13
    • 36749092900 scopus 로고    scopus 로고
    • Simultaneous determination of wave speed and arrival time of reflected waves using the pressure-velocity loop
    • DOI 10.1007/s11517-007-0241-7
    • Khir AW, Swalen MJ, Feng J, Parker KH. Simultaneous determination of wave speed and arrival time of reflected waves using the pressure-velocity loop. Med Biol Eng Comput 45: 1201-1210, 2007. (Pubitemid 350214764)
    • (2007) Medical and Biological Engineering and Computing , vol.45 , Issue.12 , pp. 1201-1210
    • Khir, A.W.1    Swalen, M.J.P.2    Feng, J.3    Parker, K.H.4
  • 14
    • 0036252346 scopus 로고    scopus 로고
    • Arterial compliance is a main variable determining the effectiveness of intra-aortic balloon counterpulsation: Quantitative data from an in vitro study
    • Papaioannou TG, Mathioulakis DS, Nanas JN, Tsangaris SG, Stamatelopoulos SF, Moulopoulos SD. Arterial compliance is a main variable determining the effectiveness of intra-aortic balloon counterpulsation: Quantitative data from an in vitro study. Med Eng Phys 24: 279-284, 2002.
    • (2002) Med Eng Phys , vol.24 , pp. 279-284
    • Papaioannou, T.G.1    Mathioulakis, D.S.2    Nanas, J.N.3    Tsangaris, S.G.4    Stamatelopoulos, S.F.5    Moulopoulos, S.D.6
  • 15
    • 3843123057 scopus 로고    scopus 로고
    • New aspects on the role of blood pressure and arterial stiffness in mechanical assistance by intra-aortic balloon pump: In-vitro data and their application in clinical practice
    • DOI 10.1111/j.1525-1594.2004.00080.x
    • Papaioannou TG, Mathioulakis DS, Stamatelopoulos KS, Gialafos EJ, Lekakis JP, Nanas J, Stamatelopoulos SF, Tsangaris SG. New aspects on the role of blood pressure and arterial stiffness in mechanical assistance by intra-aortic balloon pump: in vitro data and their application in clinical practice. Artif Organs 28: 717-727, 2004. (Pubitemid 39044644)
    • (2004) Artificial Organs , vol.28 , Issue.8 , pp. 717-727
    • Papaioannou, T.G.1    Mathioulakis, D.S.2    Stamatelopoulos, K.S.3    Gialafos, E.J.4    Lekakis, J.P.5    Nanas, J.6    Stamatelopoulos, S.F.7    Tsangaris, S.G.8
  • 16
    • 18744376046 scopus 로고    scopus 로고
    • Basic principles of the intraaortic balloon pump and mechanisms affecting its performance
    • DOI 10.1097/01.MAT.0000159381.97773.9B
    • Papaioannou TG, Stefanadis C. Basic principles of the intraaortic balloon pump and mechanisms affecting its performance. ASAIO J 51: 296-300, 2005. (Pubitemid 40677141)
    • (2005) ASAIO Journal , vol.51 , Issue.3 , pp. 296-300
    • Papaioannou, T.G.1    Stefanadis, C.2
  • 18
    • 0025473358 scopus 로고
    • Forward and backward running waves in the arteries: Analysis using the method of characteristics
    • Parker KH, Jones CJH. Forward and backward running waves in the arteries: analysis using the method of characteristics. J Biomed Eng 112: 322-326, 1990.
    • (1990) J Biomed Eng , vol.112 , pp. 322-326
    • Parker, K.H.1    Jones, C.J.H.2
  • 19
    • 38149135604 scopus 로고    scopus 로고
    • Aortic wave intensity analysis of ventricular-vascular interaction during incremental dobutamine infusion in adult sheep
    • Penny DJ, Mynard JP, Smolich JJ. Aortic wave intensity analysis of ventricular-vascular interaction during incremental dobutamine infusion in adult sheep. Am J Physiol Heart Circ Physiol 294: H481-H489, 2008.
    • (2008) Am J Physiol Heart Circ Physiol , vol.294
    • Penny, D.J.1    Mynard, J.P.2    Smolich, J.J.3
  • 21
    • 0031283341 scopus 로고    scopus 로고
    • Arterial wave intensity and ventriculoarterial interaction
    • Ramsey MW, Sugawara M. Arterial wave intensity and ventriculoarterial interaction. Heart Vessels Suppl 12: 128-134, 1997. (Pubitemid 28017754)
    • (1997) Heart and Vessels , vol.12 , Issue.SUPPL. 12 , pp. 128-134
    • Ramsey, M.W.1    Sugawara, M.2
  • 22
    • 0042553279 scopus 로고
    • Smoothing and differentiation of data by simplified least squares procedures
    • Savitzky A, Golay MJE. Smoothing and differentiation of data by simplified least squares procedures. Anal Chem 36: 1627-1639, 1964.
    • (1964) Anal Chem , vol.36 , pp. 1627-1639
    • Savitzky, A.1    Golay, M.J.E.2
  • 23
    • 14244262058 scopus 로고    scopus 로고
    • Beat-to-beat effects of intraaortic balloon pump timing on left ventricular performance in patients with low ejection fraction
    • DOI 10.1016/j.athoracsur.2004.07.073
    • Schreuder JJ, Maisano F, Donelli A, Jansen JR, Hanlon P, Bovelander J, Alfieri O. Beat-to-beat effects of intraaortic balloon pump timing on left ventricular performance in patients with low ejection fraction. Ann Thorac Surg 79: 872-880, 2005. (Pubitemid 40288740)
    • (2005) Annals of Thoracic Surgery , vol.79 , Issue.3 , pp. 872-880
    • Schreuder, J.J.1    Maisano, F.2    Donelli, A.3    Jansen, J.R.C.4    Hanlon, P.5    Bovelander, J.6    Alfieri, O.7
  • 26
    • 34548799816 scopus 로고    scopus 로고
    • Effects of intra-aortic balloon counterpulsation on coronary pressure in patients with stenotic coronary arteries
    • DOI 10.1016/j.ahj.2007.05.019, PII S000287030700511X
    • Yoshitani H, Akasaka T, Kaji S, Kawamoto T, Kume T, Neishi Y, Koyama Y, Yoshida K. Effects of intra-aortic balloon counterpulsation on coronary pressure in patients with stenotic coronary arteries. Am Heart J 154: 725-731, 2007. (Pubitemid 47429584)
    • (2007) American Heart Journal , vol.154 , Issue.4 , pp. 725-731
    • Yoshitani, H.1    Akasaka, T.2    Kaji, S.3    Kawamoto, T.4    Kume, T.5    Neishi, Y.6    Koyama, Y.7    Yoshida, K.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.