메뉴 건너뛰기




Volumn 128, Issue 4, 2008, Pages

A study on the observation of direct lightning current through the wind turbine generator system in the coast of the Japan Sea

Author keywords

Lightning stroke current; Observation; Wind turbine generator system

Indexed keywords

CLEAN ENERGY; DIRECT LIGHTNING; GENERATION CAPACITY; JAPAN SEA; LIGHTNING CURRENTS; LIGHTNING FLASHES; LIGHTNING PARAMETERS; LIGHTNING STROKES; WIND CONDITIONS; WIND TURBINE GENERATOR SYSTEMS;

EID: 72649094637     PISSN: 03854213     EISSN: 13488147     Source Type: Journal    
DOI: 10.1541/ieejpes.128.675     Document Type: Article
Times cited : (2)

References (11)
  • 2
    • 85010234768 scopus 로고    scopus 로고
    • Lightning damage of wind turbine blades and protection method of them
    • S. Yokoyama: "Lightning Damage of Wind Turbine Blades and Protection Method of them", IEEJ Trans. PE, Vol. 124, No. 2, pp. 177-180 (2004-2)
    • (2004) IEEJ Trans. PE , vol.124 , Issue.2 , pp. 177-180
    • Yokoyama, S.1
  • 4
    • 72649086318 scopus 로고    scopus 로고
    • Comparaively observed spectral radiation of natural lightning at nadachi wind power station in winter
    • in Japanese
    • T. Hori, M. Yoda, I. Miyachi, and M. Minowa: "Comparaively Observed Spectral Radiation of Natural Lightning at Nadachi Wind Power Station in Winter", 2004 National Convention Record IEE Japan, Vol. 7, No. 082, pp. 128-129 (2004) (in Japanese)
    • (2004) 2004 National Convention Record IEE Japan , vol.7 , Issue.82 , pp. 128-129
    • Hori, T.1    Yoda, M.2    Miyachi, I.3    Minowa, M.4
  • 7
    • 72649091398 scopus 로고    scopus 로고
    • Observation of winter lightning striking a wind turbine generation tower and a lightning tower
    • th ICLP, Vol. 2, XI-8, pp. 1522-1526 (2006)
    • (2006) th ICLP , vol.2 , Issue.8-11 , pp. 1522-1526
    • Sakurano, H.1    Hashimoto, M.2    Nakamura, K.3
  • 9
    • 84869734911 scopus 로고    scopus 로고
    • The observation of direct lightning stroke current to the wind turbine generator system
    • th ICLP, Vol. 2, 9 p2, pp. 1047-1052 (2004)
    • (2004) th ICLP , vol.2 , Issue.9 P2 , pp. 1047-1052
    • Shiraishi, Y.1    Otsuka, T.2    Matsuura, H.3
  • 10
    • 85010232823 scopus 로고    scopus 로고
    • Direct measurement of lightning current through a wind-turbine-oenerator- structure
    • in Japanese
    • Y. Shiraishi and T. Otsuka: "Direct Measurement of Lightning Current through a Wind-Turbine-Oenerator-Structure", IEEJ Trans, PE, Vol. 124, No. 12, pp. 1529-1535 (2004-12) (in Japanese)
    • (2004) IEEJ Trans, PE , vol.124 , Issue.12 , pp. 1529-1535
    • Shiraishi, Y.1    Otsuka, T.2
  • 11
    • 84869739145 scopus 로고    scopus 로고
    • The observation and a study of direct lightning stroke current through the wind turbine generator system
    • thICLP, Vol. 2, XI-18, pp. 1575-1579 (2006)
    • (2006) thICLP , vol.2 , Issue.11-18 , pp. 1575-1579
    • Shiraishi, Y.1    Otsuka, T.2    Matsuura, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.