메뉴 건너뛰기




Volumn 33, Issue 10, 2009, Pages 798-804

Improvement of hemocompatibility in centrifugal blood pump with hydrodynamic bearings and semi-open impeller: In vitro evaluation

Author keywords

Artificial heart; Bearing gap; Hemocompatibility; Hemolysis; Hydrody; Namic bearing; Semi open impeller; Thrombus formation

Indexed keywords

ARTIFICIAL HEART; BLOOD VESSELS; CENTRIFUGAL PUMPS; HYDRODYNAMICS; IMPELLERS; TESTING; THRUST BEARINGS;

EID: 72449196297     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2009.00817.x     Document Type: Article
Times cited : (32)

References (13)
  • 1
    • 10044219918 scopus 로고    scopus 로고
    • Current status of the gyro centrifugal blood pump - Development of the permanently implantable centrifugal blood pump as a biventricular assist device (NEDO project)
    • DOI 10.1111/j.1525-1594.2004.00073.x
    • Nosé Y, Furukawa K. Current status of the Gyro centrifugal blood pump - development of the permanently implantable centrifugal blood pump as a biventricular assist device (NEDO Project). Artif Organs 2004;28:953-958 (Pubitemid 40394480)
    • (2004) Artificial Organs , vol.28 , Issue.10 , pp. 953-958
    • Nose, Y.1    Furukawa, K.2
  • 2
    • 33646243597 scopus 로고    scopus 로고
    • Third generation blood pumps with mechanical non-contact magnetic bearing
    • Hoshi H, Shinshi T, Takatani S. Third generation blood pumps with mechanical non-contact magnetic bearing. Artif Organs 2006;30:324-339
    • (2006) Artif Organs , vol.30 , pp. 324-339
    • Hoshi, H.1    Shinshi, T.2    Takatani, S.3
  • 3
    • 0034823946 scopus 로고    scopus 로고
    • Development status of Terumo implantable left ventricular assist system
    • Nojiri C, Kijima T, Maekawa J, et al. Development status of Terumo implantable left ventricular assist system.. Artif Organs 2001;25:411-13.
    • (2001) Artif Organs , vol.25 , pp. 411-413
    • Nojiri, C.1    Kijima, T.2    Maekawa, J.3
  • 4
    • 44849106771 scopus 로고    scopus 로고
    • Properties of a monopivot magnetic suspension centrifugal pump for circulatory assist
    • Yamane T, Maruyama O, Nishida M, et al. Properties of a monopivot magnetic suspension centrifugal pump for circulatory assist. Artif Organs 2008;32:484-489
    • (2008) Artif Organs , vol.32 , pp. 484-489
    • Yamane, T.1    Maruyama, O.2    Nishida, M.3
  • 5
    • 0242678387 scopus 로고    scopus 로고
    • Testing of a Centrifugal Blood Pump with a High Efficiency Hybrid Magnetic Bearing
    • DOI 10.1097/01.MAT.0000093963.64669.96
    • Locke DH, Swanson ES, Walton JF, Willis JP, Heshmat H. Testing of a centrifugal blood pump with a high efficiency hybrid magnetic bearing. ASAIO J 2003;49:737-743 (Pubitemid 37429678)
    • (2003) ASAIO Journal , vol.49 , Issue.6 , pp. 737-743
    • Locke, D.H.1    Swanson, E.S.2    Walton II, J.F.3    Willis, J.P.4    Heshmat, H.5
  • 7
    • 33644968718 scopus 로고    scopus 로고
    • The pivot wash in two impeller modes for the Baylor/Miwatec centrifugal blood pump
    • Yamane T, Kodama T, Nishida M, et al. The pivot wash in two impeller modes for the Baylor/Miwatec centrifugal blood pump. Artif Organs 2006;30:70-73
    • (2006) Artif Organs , vol.30 , pp. 70-73
    • Yamane, T.1    Kodama, T.2    Nishida, M.3
  • 8
    • 72449206605 scopus 로고    scopus 로고
    • And control of a magnetic bearing system for the magnetically suspended centrifugal blood pump
    • Kim H, Kim. HC. Modeling and control of a magnetic bearing system for the magnetically suspended centrifugal blood pump. J Artif Organs 2000;23:47-51.
    • (2000) J Artif Organs , vol.23 , pp. 47-51
    • Kim, H.1    Modeling, K.H.C.2
  • 9
    • 0031238930 scopus 로고    scopus 로고
    • Magnetic suspension controls for a new continuous flow ventricular assist device
    • Hilton EF, Allaire PE, Baloh MJ, et al. Magnetic suspension controls for a new continuous flow ventricular assist device. ASAIO J 1997;43:M598-603.
    • (1997) ASAIO J , vol.43
    • Hilton, E.F.1    Allaire, P.E.2    Baloh, M.J.3
  • 11
    • 72449175225 scopus 로고    scopus 로고
    • Simple in vitro testing method for antithrombogenic evaluation of centrifugal blood pumps
    • [Abstract]
    • Maruyama O, Tomari Y, Sugiyama D, Nishida M, Tsutsui T, Yamane T. Simple in vitro testing method for antithrombogenic evaluation of centrifugal blood pumps. ASAIO J 2006;52:5A. [Abstract].
    • (2006) ASAIO J , vol.52
    • Maruyama, O.1    Tomari, Y.2    Sugiyama, D.3    Nishida, M.4    Tsutsui, T.5    Yamane, T.6
  • 12
    • 72449154627 scopus 로고    scopus 로고
    • Repeatability of in vitro antithrombogenic testing of centrifugal blood pumps
    • [Abstract]
    • Maruyama O, Tomari Y, Nishida M, Tsutsui T, Yamane T. Repeatability of in vitro antithrombogenic testing of centrifugal blood pumps. ASAIO J 2007;53:7A. [Abstract].
    • (2007) ASAIO J , vol.53
    • Maruyama, O.1    Tomari, Y.2    Nishida, M.3    Tsutsui, T.4    Yamane, T.5
  • 13
    • 33845487963 scopus 로고    scopus 로고
    • Hemolytic performance of a MagLev disposable rotary blood pump (MedTech Dispo): Effects of MagLev gap clearance and surface roughness
    • DOI 10.1111/j.1525-1594.2006.00332.x
    • Hoshi H, Asama J, Hara C, et al. Hemolytic performance of a MagLev disposable rotary blood pump (MedTech Dispo): effects of MagLev gap clearance and surface roughness. Artif Organs 2006;30:949-954 (Pubitemid 44915583)
    • (2006) Artificial Organs , vol.30 , Issue.12 , pp. 949-954
    • Hoshi, H.1    Asama, J.2    Hijikata, W.3    Hara, C.4    Shinshi, T.5    Yasuda, T.6    Ohuchi, K.7    Shimokohbe, A.8    Takatani, S.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.