메뉴 건너뛰기




Volumn 94, Issue 2, 2010, Pages 212-220

Innovative solar windows for cooling-demand climate

Author keywords

Advanced fenestration system; Building thermal performance; Glazing optical properties; Water flow window

Indexed keywords

ADVANCED FENESTRATION SYSTEM; BUILDING THERMAL PERFORMANCE; DESIGN OPTION; ENERGY PERFORMANCE; FENESTRATION SYSTEMS; GLAZING OPTICAL PROPERTIES; HOT-WATER SUPPLY; NEW DESIGN; NUMERICAL COMPUTATIONS; PHYSICAL STRUCTURES; RAPID EVOLUTION; VISUAL COMFORT;

EID: 72449162032     PISSN: 09270248     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.solmat.2009.09.004     Document Type: Article
Times cited : (218)

References (41)
  • 1
    • 0032194217 scopus 로고    scopus 로고
    • Assessing the overall performance of advanced glazing systems
    • Clarke J.A., Janak M., and Ruyssevelt P. Assessing the overall performance of advanced glazing systems. Solar Energy 63 (1998) 231-241
    • (1998) Solar Energy , vol.63 , pp. 231-241
    • Clarke, J.A.1    Janak, M.2    Ruyssevelt, P.3
  • 2
    • 34447645795 scopus 로고    scopus 로고
    • Experimental assessment of the performance of an active transparent facade during actual operating conditions
    • Corgnati S.P., Perino M., and Serra V. Experimental assessment of the performance of an active transparent facade during actual operating conditions. Solar Energy 81 (2007) 993-1013
    • (2007) Solar Energy , vol.81 , pp. 993-1013
    • Corgnati, S.P.1    Perino, M.2    Serra, V.3
  • 3
    • 58549107989 scopus 로고    scopus 로고
    • High-efficiency multistable switchable glazing using smectic A liquid crystals
    • Gardiner D.J., Morris S.M., and Coles H.J. High-efficiency multistable switchable glazing using smectic A liquid crystals. Solar Energy Materials and Solar Cells 93 (2009) 301-306
    • (2009) Solar Energy Materials and Solar Cells , vol.93 , pp. 301-306
    • Gardiner, D.J.1    Morris, S.M.2    Coles, H.J.3
  • 4
    • 72449158847 scopus 로고    scopus 로고
    • ASHRAE, ASHRAE Handbook: Fundamentals, SI ed., Chapter 31, American Society of Heating, Refrigerating and Air-conditioning Engineers Inc., Atlanta, USA, 2005.
    • ASHRAE, ASHRAE Handbook: Fundamentals, SI ed., Chapter 31, American Society of Heating, Refrigerating and Air-conditioning Engineers Inc., Atlanta, USA, 2005.
  • 5
    • 0038713414 scopus 로고    scopus 로고
    • Proposed reference irradiance spectra for solar energy systems testing
    • Gueymard C.A., Myers D., and Emery K. Proposed reference irradiance spectra for solar energy systems testing. Solar Energy 73 (2002) 443-467
    • (2002) Solar Energy , vol.73 , pp. 443-467
    • Gueymard, C.A.1    Myers, D.2    Emery, K.3
  • 6
    • 64249085530 scopus 로고    scopus 로고
    • Heat transfer modelling on windows and glazing under the explosure of solar radiation
    • Pal S., Roy B., and Neogi S. Heat transfer modelling on windows and glazing under the explosure of solar radiation. Energy and Buildings 41 (2009) 654-661
    • (2009) Energy and Buildings , vol.41 , pp. 654-661
    • Pal, S.1    Roy, B.2    Neogi, S.3
  • 8
    • 34047185316 scopus 로고    scopus 로고
    • Performance evaluation of a PV ventilated window applying to office building of Hong Kong
    • Chow T.T., Fong K.F., He W., Lin Z., and Chan A.L.S. Performance evaluation of a PV ventilated window applying to office building of Hong Kong. Energy and Buildings 39 (2007) 643-650
    • (2007) Energy and Buildings , vol.39 , pp. 643-650
    • Chow, T.T.1    Fong, K.F.2    He, W.3    Lin, Z.4    Chan, A.L.S.5
  • 9
    • 67349284853 scopus 로고    scopus 로고
    • Thermal performance of natural airflow window in subtropical and temperate climate zones - a comparative study
    • Chow T.T., Lin Z., Fong K.F., Chan L.S., and He M.M. Thermal performance of natural airflow window in subtropical and temperate climate zones - a comparative study. Energy Conversion and Management 50 (2009) 1884-1890
    • (2009) Energy Conversion and Management , vol.50 , pp. 1884-1890
    • Chow, T.T.1    Lin, Z.2    Fong, K.F.3    Chan, L.S.4    He, M.M.5
  • 10
    • 72449148867 scopus 로고    scopus 로고
    • US Department of Energy, Lawrence Berkeley National Laboratory, Window 5.2 Knowledge Base website: http://windows.lbl.gov/software/window/52/W52_faq.html.
    • US Department of Energy, Lawrence Berkeley National Laboratory, Window 5.2 Knowledge Base website: http://windows.lbl.gov/software/window/52/W52_faq.html.
  • 14
    • 36149001364 scopus 로고    scopus 로고
    • Opportunities and challenges in science and technology of WO3 for electrochromic and related sapplications
    • Deb S.K. Opportunities and challenges in science and technology of WO3 for electrochromic and related sapplications. Solar Energy Materials and Solar Cells 92 (2008) 245-258
    • (2008) Solar Energy Materials and Solar Cells , vol.92 , pp. 245-258
    • Deb, S.K.1
  • 15
    • 65549096433 scopus 로고    scopus 로고
    • Daylighting performance of an electrochromic window in a small scale test-cell
    • Piccolo A., Pennisi A., and Simone F. Daylighting performance of an electrochromic window in a small scale test-cell. Solar Energy 83 (2009) 832-844
    • (2009) Solar Energy , vol.83 , pp. 832-844
    • Piccolo, A.1    Pennisi, A.2    Simone, F.3
  • 16
    • 60549107481 scopus 로고    scopus 로고
    • Effect of switchable glazing on discomfort glare from windows
    • Piccolo A., and Simone F. Effect of switchable glazing on discomfort glare from windows. Building and Environment 44 (2009) 1171-1180
    • (2009) Building and Environment , vol.44 , pp. 1171-1180
    • Piccolo, A.1    Simone, F.2
  • 17
    • 37349111505 scopus 로고    scopus 로고
    • Study on thermal performance of semi-transparent building-integrated photovoltaic glazings
    • Fung T.Y.Y., and Yang H. Study on thermal performance of semi-transparent building-integrated photovoltaic glazings. Energy and Buildings 40 (2008) 341-350
    • (2008) Energy and Buildings , vol.40 , pp. 341-350
    • Fung, T.Y.Y.1    Yang, H.2
  • 18
    • 0028480189 scopus 로고
    • The intelligent façade photovoltaic and architecture
    • Chehab O. The intelligent façade photovoltaic and architecture. Renewable Energy 5 (1994) 188-204
    • (1994) Renewable Energy , vol.5 , pp. 188-204
    • Chehab, O.1
  • 19
    • 0036777270 scopus 로고    scopus 로고
    • Industrial manufacturing of semitransparent crystalline silicon POWER solar cells
    • Fath P., Nussbaumer H., and Burkhardt R. Industrial manufacturing of semitransparent crystalline silicon POWER solar cells. Solar Energy Materials & Solar Cells 74 (2002) 127-131
    • (2002) Solar Energy Materials & Solar Cells , vol.74 , pp. 127-131
    • Fath, P.1    Nussbaumer, H.2    Burkhardt, R.3
  • 20
    • 38349087605 scopus 로고    scopus 로고
    • Semi-transparent PV: thermal performance, power generation, daylight modelling and energy saving potential in a residential application
    • Wong P.W., Shimod Y., Nonaka M., Inoue M., and Mizuno M. Semi-transparent PV: thermal performance, power generation, daylight modelling and energy saving potential in a residential application. Renewable Energy 33 (2008) 1024-1036
    • (2008) Renewable Energy , vol.33 , pp. 1024-1036
    • Wong, P.W.1    Shimod, Y.2    Nonaka, M.3    Inoue, M.4    Mizuno, M.5
  • 22
    • 6044275874 scopus 로고    scopus 로고
    • Energy savings of office buildings by the use of semi-transparent solar cells for windows
    • Miyazaki T., Akisawa A., and Kashiwagi T. Energy savings of office buildings by the use of semi-transparent solar cells for windows. Renewable Energy 30 (2005) 281-304
    • (2005) Renewable Energy , vol.30 , pp. 281-304
    • Miyazaki, T.1    Akisawa, A.2    Kashiwagi, T.3
  • 23
    • 0032209940 scopus 로고    scopus 로고
    • Heat transfer through a double pane window with an insulation screen open at the top
    • Medved S., and Novak P. Heat transfer through a double pane window with an insulation screen open at the top. Energy and Buildings 28 (1998) 257-268
    • (1998) Energy and Buildings , vol.28 , pp. 257-268
    • Medved, S.1    Novak, P.2
  • 24
    • 33748925401 scopus 로고    scopus 로고
    • Application of advanced glazing to high-rise residential buildings in Hong Kong
    • Bojic M., and Yik F. Application of advanced glazing to high-rise residential buildings in Hong Kong. Building and Environment 42 (2007) 820-828
    • (2007) Building and Environment , vol.42 , pp. 820-828
    • Bojic, M.1    Yik, F.2
  • 25
    • 33846082833 scopus 로고    scopus 로고
    • Solar filters based on iron oxides used as efficient windows for energy savings
    • Chavez-Galan J., and Almanza R. Solar filters based on iron oxides used as efficient windows for energy savings. Solar Energy 81 (2007) 13-19
    • (2007) Solar Energy , vol.81 , pp. 13-19
    • Chavez-Galan, J.1    Almanza, R.2
  • 27
    • 38549083301 scopus 로고    scopus 로고
    • Potential of emerging glazing technologies for highly glazed buildings in hot arid climates
    • Bahaj A.S., James P.A.B., and Jentsch M.F. Potential of emerging glazing technologies for highly glazed buildings in hot arid climates. Energy and Buildings 40 (2008) 720-731
    • (2008) Energy and Buildings , vol.40 , pp. 720-731
    • Bahaj, A.S.1    James, P.A.B.2    Jentsch, M.F.3
  • 28
    • 45249102007 scopus 로고    scopus 로고
    • Different glazing systems and their impact on human thermal comfort-Indian scenario
    • Singh M.C., Garg S.N., and Jha R. Different glazing systems and their impact on human thermal comfort-Indian scenario. Building and Environment 43 (2008) 1596-1602
    • (2008) Building and Environment , vol.43 , pp. 1596-1602
    • Singh, M.C.1    Garg, S.N.2    Jha, R.3
  • 29
    • 0037333127 scopus 로고    scopus 로고
    • Numerical simulation of heat transfer by natural convection in cavities of facade elements
    • Manz H. Numerical simulation of heat transfer by natural convection in cavities of facade elements. Energy and Buildings 35 (2003) 305-311
    • (2003) Energy and Buildings , vol.35 , pp. 305-311
    • Manz, H.1
  • 30
    • 33745161809 scopus 로고    scopus 로고
    • Non-gray radiative convective conductive modeling of a double glass window with a cavity filled with a mixture of absorbing gases
    • Ismail K.A.R., and Salinas C. Non-gray radiative convective conductive modeling of a double glass window with a cavity filled with a mixture of absorbing gases. International Journal of Heat and Mass Transfer 49 (2006) 2972-2983
    • (2006) International Journal of Heat and Mass Transfer , vol.49 , pp. 2972-2983
    • Ismail, K.A.R.1    Salinas, C.2
  • 31
    • 35549011396 scopus 로고    scopus 로고
    • On minimizing heat transport in architectural glazing
    • Manz H. On minimizing heat transport in architectural glazing. Renewable Energy 33 (2008) 119-128
    • (2008) Renewable Energy , vol.33 , pp. 119-128
    • Manz, H.1
  • 32
    • 38549145518 scopus 로고    scopus 로고
    • Comparison between PCM filled glass windows and absorbing gas filled windows
    • Ismail K.A.R., Salinas C.T., and Henriquez J.R. Comparison between PCM filled glass windows and absorbing gas filled windows. Energy and Buildings 40 (2008) 710-719
    • (2008) Energy and Buildings , vol.40 , pp. 710-719
    • Ismail, K.A.R.1    Salinas, C.T.2    Henriquez, J.R.3
  • 33
    • 33846813524 scopus 로고    scopus 로고
    • Effect of glass thickness on the thermal performance of evacuated glazing
    • Fang Y., Eames P.C., and Norton B. Effect of glass thickness on the thermal performance of evacuated glazing. Solar Energy 81 (2007) 395-404
    • (2007) Solar Energy , vol.81 , pp. 395-404
    • Fang, Y.1    Eames, P.C.2    Norton, B.3
  • 35
    • 33646877069 scopus 로고    scopus 로고
    • Experimental characterization and detailed performance prediction of a vacuum glazing system fabricated with a low temperature metal edge seal, using a validated computer model
    • Griffiths P.W., Eames P.C., Hyde J.T., Fang Y., and Norton B. Experimental characterization and detailed performance prediction of a vacuum glazing system fabricated with a low temperature metal edge seal, using a validated computer model. ASME Journal of Solar Energy Engineering 128 (2006) 199-203
    • (2006) ASME Journal of Solar Energy Engineering , vol.128 , pp. 199-203
    • Griffiths, P.W.1    Eames, P.C.2    Hyde, J.T.3    Fang, Y.4    Norton, B.5
  • 36
    • 67349244923 scopus 로고    scopus 로고
    • A comparative study of naturally ventilated and gas filled windows for hot climates
    • Ismail K.A.R., Salinas C.T., and Henriquez J.R. A comparative study of naturally ventilated and gas filled windows for hot climates. Energy Conversion and Management 50 (2009) 1691-1703
    • (2009) Energy Conversion and Management , vol.50 , pp. 1691-1703
    • Ismail, K.A.R.1    Salinas, C.T.2    Henriquez, J.R.3
  • 37
    • 0033895978 scopus 로고    scopus 로고
    • Controlling the transmission of radiant energy through windows: a novel ventilated reversible glazing system
    • Etzion Y., and Erell E. Controlling the transmission of radiant energy through windows: a novel ventilated reversible glazing system. Building and Environment 35 (2000) 433-444
    • (2000) Building and Environment , vol.35 , pp. 433-444
    • Etzion, Y.1    Erell, E.2
  • 38
    • 33746127059 scopus 로고    scopus 로고
    • Modeling a reversible ventilated window for simulation within ESP-r-the SOLVENT case
    • 11-14 August, Eindhoven, The Netherlands, pp
    • V. Leal, E. Maldonado, E. Erell, Y. Etzion, Modeling a reversible ventilated window for simulation within ESP-r-the SOLVENT case, in: Proceedings of the Eighth International IBPSA Conference, 11-14 August 2003, Eindhoven, The Netherlands, pp. 713-720.
    • (2003) Proceedings of the Eighth International IBPSA Conference , pp. 713-720
    • Leal, V.1    Maldonado, E.2    Erell, E.3    Etzion, Y.4
  • 39
    • 33947391287 scopus 로고    scopus 로고
    • Saving energy in residential buildings: the use of fully reversible windows
    • Gugliermetti F., and Bisegna F. Saving energy in residential buildings: the use of fully reversible windows. Energy 32 (2007) 1235-1247
    • (2007) Energy , vol.32 , pp. 1235-1247
    • Gugliermetti, F.1    Bisegna, F.2
  • 40
    • 37349008984 scopus 로고    scopus 로고
    • A computational method for calculating heat transfer and airflow through a dual-airflow window
    • Gosselin J.R., and Chen Q. A computational method for calculating heat transfer and airflow through a dual-airflow window. Energy and Buidings 40 (2008) 452-458
    • (2008) Energy and Buidings , vol.40 , pp. 452-458
    • Gosselin, J.R.1    Chen, Q.2
  • 41
    • 57749193729 scopus 로고    scopus 로고
    • Potential application of "see-through" solar cells in ventilated glazing in Hong Kong
    • Chow T.T., Qiu Z.Z., and Li C.Y. Potential application of "see-through" solar cells in ventilated glazing in Hong Kong. Solar Energy Materials and Solar Cells 93 (2009) 230-238
    • (2009) Solar Energy Materials and Solar Cells , vol.93 , pp. 230-238
    • Chow, T.T.1    Qiu, Z.Z.2    Li, C.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.