메뉴 건너뛰기




Volumn 54, Issue 3, 2009, Pages 33-44

Tomographic investigations of wood from macroscopic to microscopic scale

Author keywords

Neutron tomography; Non destructive testing; Synchrotron microtomography; X ray tomography

Indexed keywords

APPLICATION AREA; CELL WALLS; CHARACTERISATION; COLD NEUTRON; COMPUTED TOMOGRAPHY; DYNAMIC PROCESS; HIGH SENSITIVITY; IONISING RADIATION; LIGHT ELEMENTS; MACROSCOPIC LEVELS; MICROSCOPIC SCALE; NEUTRON TOMOGRAPHY; NON DESTRUCTIVE TESTING; SWITZERLAND; SYNCHROTRON MICROTOMOGRAPHY; TOMOGRAPHIC; TOMOGRAPHIC METHODS; TOMOGRAPHY METHODS; TRANSMISSION MEASUREMENTS; WOOD-BASED MATERIALS; WOODEN OBJECTS; X-RAY TOMOGRAPHY;

EID: 72449161623     PISSN: 13364561     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (11)

References (10)
  • 2
    • 0016685858 scopus 로고
    • Theory of image reconstruction in computed tomography
    • Brooks, R.A., Di Chiro, G., 1975: Theory of image reconstruction in computed tomography. Radiology 117: 561-572
    • (1975) Radiology , vol.117 , pp. 561-572
    • Brooks, R.A.1    Di Chiro, G.2
  • 3
    • 0348172012 scopus 로고    scopus 로고
    • Techniques for high resolution imaging of wood structure: A review
    • DOI 10.1088/0957-0233/14/12/R01, PII S0957023303390447
    • 3. Bucur, V., 2003: Techniques for high resolution imaging of wood structure: A review. Measurement Science & Technology 14(12): R91-R98 (Pubitemid 38034036)
    • (2003) Measurement Science and Technology , vol.14 , Issue.12
    • Bucur, V.1
  • 4
    • 0001069532 scopus 로고
    • Representation of a function by its line integrals, with some radiological applications
    • Cormack, A.M., 1963: Representation of a function by its line integrals, with some radiological applications. Journal of Applied Physics. 34(9): 2722-2727
    • (1963) Journal of Applied Physics , vol.34 , Issue.9 , pp. 2722-2727
    • Cormack, A.M.1
  • 5
    • 33751232346 scopus 로고    scopus 로고
    • Scattering correction algorithm for neutron radiography and tomography tested at facilities with different beam characteristics
    • DOI 10.1016/j.physb.2006.05.406, PII S0921452606012981
    • Hassanein, R., de Beer, F., Kardjilov, N., Lehmann, E., 2006: Scattering correction algorithm for neutron radiography and tomography tested at facilities with different beam characteristics. Physica B - condensed matter 385-86: 1194-1196 Part 2 (Pubitemid 44792995)
    • (2006) Physica B - Condensed Matter , vol.385-386 , Issue.PART 2 , pp. 1194-1196
    • Hassanein, R.1    De Beer, F.2    Kardjilov, N.3    Lehmann, E.4
  • 6
    • 0019198182 scopus 로고
    • Computed medical imaging
    • Hounsfield, G., 1980: Computed medical imaging, Science 210(4465): 22-28
    • (1980) Science , vol.210 , Issue.4465 , pp. 22-28
    • Hounsfield, G.1
  • 7
    • 0034878553 scopus 로고    scopus 로고
    • Properties of the radiography facility NEUTRA at SINQ and its potential for use as european reference facility
    • Lehmann, E.H., Vontobel, P., Wiezel, L., 2001: Properties of the Radiography Facility NEUTRA at SINQ and its Potential for Use as European Reference Facility. Nondestructive Testing and Evaluation 16:191202
    • (2001) Nondestructive Testing and Evaluation , vol.16 , pp. 191202
    • Lehmann, E.H.1    Vontobel, P.2    Wiezel, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.