메뉴 건너뛰기




Volumn 19, Issue 5, 2004, Pages 721-730

Immediate loading of dental implants in the completely edentulous maxilla: A clinical report

Author keywords

Dental implants; Early loading; Immediate loading; Osseointegration

Indexed keywords

AMOXICILLIN; CHLORHEXIDINE; LOCAL ANESTHETIC AGENT;

EID: 7244255807     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (87)

References (18)
  • 1
    • 0017564248 scopus 로고
    • Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period
    • Brånemark P-I, Hansson BO, Adell R, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg 1977;16:1-132.
    • (1977) Scand J Plast Reconstr Surg , vol.16 , pp. 1-132
    • Brånemark, P.-I.1    Hansson, B.O.2    Adell, R.3
  • 2
    • 0031152016 scopus 로고    scopus 로고
    • Long-term evaluation of non-submerged ITI implants. Part 1: 8-Year life table analysis of a prospective multi-center study with 2359 implants
    • Buser D, Mericske-Stern R, Bernard JP, et al. Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants. Clin Oral Implants Res 1997;8:161-172.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 161-172
    • Buser, D.1    Mericske-Stern, R.2    Bernard, J.P.3
  • 4
    • 0033140443 scopus 로고    scopus 로고
    • In vivo bone response to biomechanical loading at the bone/dental-implant interface
    • Brunski JB. In vivo bone response to biomechanical loading at the bone/dental-implant interface. Adv Dent Res 1999;13:99-119.
    • (1999) Adv Dent Res , vol.13 , pp. 99-119
    • Brunski, J.B.1
  • 5
    • 0032102958 scopus 로고    scopus 로고
    • Timing of loading and effect of micromotion on bone-dental implant interface: Review of experimental literature
    • Szmukler-Moncler S, Salama H, Reingewirtz Y, Dubruille JH. Timing of loading and effect of micromotion on bone-dental implant interface: Review of experimental literature. J Biomed Mater Res 1998;43:192-203.
    • (1998) J Biomed Mater Res , vol.43 , pp. 192-203
    • Szmukler-Moncler, S.1    Salama, H.2    Reingewirtz, Y.3    Dubruille, J.H.4
  • 7
    • 0031136510 scopus 로고    scopus 로고
    • Immediate loading of threaded implants at stage 1 surgery in edentulous arches: Ten consecutive case reports with 1- to 5-year data
    • Tarnow DP, Emtiaz S, Classi A. Immediate loading of threaded implants at stage 1 surgery in edentulous arches: Ten consecutive case reports with 1- to 5-year data. Int J Oral Maxillofac Implants 1997;12:319-324.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 319-324
    • Tarnow, D.P.1    Emtiaz, S.2    Classi, A.3
  • 8
    • 0034183762 scopus 로고    scopus 로고
    • Immediate loading of implants in partially and fully edentulous jaws: A series of 27 case reports
    • Jaffin RA, Kumar A, Berman CL. Immediate loading of implants in partially and fully edentulous jaws: A series of 27 case reports. J Periodontol 2000;71:833-838.
    • (2000) J Periodontol , vol.71 , pp. 833-838
    • Jaffin, R.A.1    Kumar, A.2    Berman, C.L.3
  • 9
    • 0035350613 scopus 로고    scopus 로고
    • Immediate loading of implants with fixed restorations for the fully edentulous mandible: Report of 27 cases from a private practice
    • Ganeles J, Rosenberg MM, Holt RE, Reichman LH. Immediate loading of implants with fixed restorations for the fully edentulous mandible: Report of 27 cases from a private practice. Int J Oral Maxillofac Implants 2001;16:418-426.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 418-426
    • Ganeles, J.1    Rosenberg, M.M.2    Holt, R.E.3    Reichman, L.H.4
  • 10
    • 0037648483 scopus 로고    scopus 로고
    • Immediate loading of root-form implants: Two case reports 3 years after loading
    • Levine R, Rose L, Salama H. Immediate loading of root-form implants: Two case reports 3 years after loading. Int J Periodontics Restorative Dent 1998;18:333-343.
    • (1998) Int J Periodontics Restorative Dent , vol.18 , pp. 333-343
    • Levine, R.1    Rose, L.2    Salama, H.3
  • 11
    • 0030829167 scopus 로고    scopus 로고
    • Distribution of bone quality in patients receiving endosseous dental implants
    • Truhlar RS, Orenstein IH, Morris HF, Ochi S. Distribution of bone quality in patients receiving endosseous dental implants. J Oral Maxillofac Surg 1997;55(12 suppl 5):38-45.
    • (1997) J Oral Maxillofac Surg , vol.55 , Issue.12 SUPPL. 5 , pp. 38-45
    • Truhlar, R.S.1    Orenstein, I.H.2    Morris, H.F.3    Ochi, S.4
  • 13
    • 0031309247 scopus 로고    scopus 로고
    • Influence of bone quality on stress distribution for endosseous implants
    • Holmes DC, Loftus JT. Influence of bone quality on stress distribution for endosseous implants. J Oral Implantol 1997;23:104-111.
    • (1997) J Oral Implantol , vol.23 , pp. 104-111
    • Holmes, D.C.1    Loftus, J.T.2
  • 14
    • 0032276922 scopus 로고    scopus 로고
    • Influence of percentage of osseointegration on stress distribution around dental implants
    • Lai H, Zhang F, Zhang B, Yang C, Xue M. Influence of percentage of osseointegration on stress distribution around dental implants. Chin J Dent Res 1998;1:7-11.
    • (1998) Chin J Dent Res , vol.1 , pp. 7-11
    • Lai, H.1    Zhang, F.2    Zhang, B.3    Yang, C.4    Xue, M.5
  • 16
    • 0036547410 scopus 로고    scopus 로고
    • The use of reduced healing times on ITI implants with a sandblasted and acid-etched (SLA) surface: Early results from clinical trials on ITI SLA implants
    • Cochran DL, Buser D, ten Bruggenkate CM, et al. The use of reduced healing times on ITI implants with a sandblasted and acid-etched (SLA) surface: Early results from clinical trials on ITI SLA implants. Clin Oral Implants Res 2002;13:144-153.
    • (2002) Clin Oral Implants Res , vol.13 , pp. 144-153
    • Cochran, D.L.1    Buser, D.2    Ten Bruggenkate, C.M.3
  • 17
    • 0036836264 scopus 로고    scopus 로고
    • The effect of smoking on achieving osseointegration of surface-modified implants: A clinical report
    • Kumar A, Jaffin RA, Berman CL. The effect of smoking on achieving osseointegration of surface-modified implants: A clinical report. Int J Oral Maxillofac Implants 2002;17:816-819.
    • (2002) Int J Oral Maxillofac Implants , vol.17 , pp. 816-819
    • Kumar, A.1    Jaffin, R.A.2    Berman, C.L.3
  • 18
    • 0034570059 scopus 로고    scopus 로고
    • Implant-abutment interface: Biomechanical study of flat top versus conical
    • Hansson S. Implant-abutment interface: Biomechanical study of flat top versus conical. Clin Implant Dent Relat Res 2000;2:33-41.
    • (2000) Clin Implant Dent Relat Res , vol.2 , pp. 33-41
    • Hansson, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.