메뉴 건너뛰기




Volumn 31, Issue 10, 2004, Pages 2819-2825

Influence of x-ray pulse parameters on the image quality for moving objects in digital cardiac imaging

Author keywords

Cardiac imaging; Digital fluoroscopy; Image quality; Organ motion; Patient dose

Indexed keywords

FULL WIDTH AT HALF MAXIMUM; HEART; IMAGE QUALITY; OBJECT DETECTION; SIGNAL DETECTION; SIGNAL TO NOISE RATIO; X RAYS;

EID: 7244254278     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1790091     Document Type: Article
Times cited : (5)

References (13)
  • 1
    • 0025140782 scopus 로고
    • Comparison of digital and cine coronary arteriography
    • J. C. Gurley and S. E. Nissen, "Comparison of digital and cine coronary arteriography," Int. J. Card. Imaging 5, 105-118 (1990).
    • (1990) Int. J. Card. Imaging , vol.5 , pp. 105-118
    • Gurley, J.C.1    Nissen, S.E.2
  • 2
    • 0031283360 scopus 로고    scopus 로고
    • Quantitative coronary angiography: Impact of imaging parameters on accuracy and confidence interval
    • H. Seissl, K. Peukert, B. Geiger, and B. J. Verstraelen, "Quantitative coronary angiography: impact of imaging parameters on accuracy and confidence interval," Heart Vessels Suppl. 12, 212-216 (1997).
    • (1997) Heart Vessels Suppl. , vol.12 , pp. 212-216
    • Seissl, H.1    Peukert, K.2    Geiger, B.3    Verstraelen, B.J.4
  • 3
    • 0028285830 scopus 로고
    • Reduction of radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel x-ray tube technology with extra beam filtering
    • A. den Boer, P. J. de Feyter, W. A. Hummel, D. Keanne, and J. R. Roelandt, "Reduction of radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel x-ray tube technology with extra beam filtering," Circulation 89, 2710-2714 (1994).
    • (1994) Circulation , vol.89 , pp. 2710-2714
    • Den Boer, A.1    De Feyter, P.J.2    Hummel, W.A.3    Keanne, D.4    Roelandt, J.R.5
  • 4
    • 0028672038 scopus 로고
    • A model for perception of pulsed fluoroscopy image sequences
    • R. Aufrichtig, C. Thomas, P. Xue, and D. L. Wilson, "A model for perception of pulsed fluoroscopy image sequences," J. Opt. Soc. Am. A 11, 3167-3176 (1994).
    • (1994) J. Opt. Soc. Am. A , vol.11 , pp. 3167-3176
    • Aufrichtig, R.1    Thomas, C.2    Xue, P.3    Wilson, D.L.4
  • 5
    • 0031987315 scopus 로고    scopus 로고
    • Detection of moving objects in pulsed x-ray fluoroscopy
    • P. Xue and D. L. Wilson, "Detection of moving objects in pulsed x-ray fluoroscopy," J. Opt. Soc. Am. A 15, 375-388 (1998).
    • (1998) J. Opt. Soc. Am. A , vol.15 , pp. 375-388
    • Xue, P.1    Wilson, D.L.2
  • 6
    • 0031804914 scopus 로고    scopus 로고
    • Effects of motion in x-ray fluoroscopy
    • P. Xue and D. L. Wilson, "Effects of motion in x-ray fluoroscopy," Med. Phys. 25, 587-599 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 587-599
    • Xue, P.1    Wilson, D.L.2
  • 7
    • 0025666245 scopus 로고
    • Perceived sharpness in moving images
    • J. H. D. M. Westerink and C. Teunissen, "Perceived sharpness in moving images," Proc. SPIE 1249, 78-87 (1990).
    • (1990) Proc. SPIE , vol.1249 , pp. 78-87
    • Westerink, J.H.D.M.1    Teunissen, C.2
  • 8
    • 0022369230 scopus 로고
    • The effects of motion on quantitative vessel measurements
    • D. L. Parker, P. D. Clayton, and D. E. Gustafson, "The effects of motion on quantitative vessel measurements," Med. Phys. 12, 698-704 (1985).
    • (1985) Med. Phys. , vol.12 , pp. 698-704
    • Parker, D.L.1    Clayton, P.D.2    Gustafson, D.E.3
  • 9
    • 0031860874 scopus 로고    scopus 로고
    • Quantification of in-plane motion of the coronary arteries during the cardiac cycle: Implications for acquisition window duration for MR flow quantification
    • M. B. Hofman, S. A. Wickline, and C. H. Lorenz, "Quantification of in-plane motion of the coronary arteries during the cardiac cycle: Implications for acquisition window duration for MR flow quantification," J. Magn. Reson Imaging 8, 568-576 (1998).
    • (1998) J. Magn. Reson Imaging , vol.8 , pp. 568-576
    • Hofman, M.B.1    Wickline, S.A.2    Lorenz, C.H.3
  • 11
    • 0020027019 scopus 로고
    • Quantitative analysis of segmental wall motion throughout systole and diastole in the normal human left ventricle
    • S. C. Klausner, T. J. Blair, W. F. Bulawa, G. M. Jeppson, R. L. Jensen, and P. D. Clayton, "Quantitative analysis of segmental wall motion throughout systole and diastole in the normal human left ventricle," Circulation 65, 580-590 (1982).
    • (1982) Circulation , vol.65 , pp. 580-590
    • Klausner, S.C.1    Blair, T.J.2    Bulawa, W.F.3    Jeppson, G.M.4    Jensen, R.L.5    Clayton, P.D.6
  • 12
    • 0019936945 scopus 로고
    • The optimization of signal detectability in digital fluoroscopy
    • R. G. Zamenhof, "The optimization of signal detectability in digital fluoroscopy," Med. Phys. 9, 688-694 (1982).
    • (1982) Med. Phys. , vol.9 , pp. 688-694
    • Zamenhof, R.G.1
  • 13
    • 0041387333 scopus 로고    scopus 로고
    • Signal detectability in digital radiography: Spatial domain figure of merits
    • R. M. Gagne, J. S. Boswell, and K. J. Myers. "Signal detectability in digital radiography: Spatial domain figure of merits," Med. Phys. 30, 2180-2193 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 2180-2193
    • Gagne, R.M.1    Boswell, J.S.2    Myers, K.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.