메뉴 건너뛰기




Volumn 101, Issue SUPPL. 3, 2004, Pages 334-340

Significance of different conformity indices for evaluation of radiosurgery treatment plans for vestibular schwannomas

Author keywords

Conformity; Conformity index; Novalis; Prescription isodose; Radiosurgery; Vestibular schwannoma

Indexed keywords

CONFERENCE PAPER; CORRELATION ANALYSIS; HUMAN; MATHEMATICAL COMPUTING; MEDICAL ASSESSMENT; NEURILEMOMA; NEUROSURGERY; PRESCRIPTION; PRIORITY JOURNAL; RADIATION DOSE; RADIATION RESPONSE; RADIOSURGERY; SCORING SYSTEM; STATISTICAL SIGNIFICANCE; SYSTEM ANALYSIS; TECHNIQUE; TREATMENT PLANNING; VESTIBULAR SYSTEM;

EID: 7244221502     PISSN: 00223085     EISSN: None     Source Type: Journal    
DOI: 10.3171/sup.2004.101.supplement3.0334     Document Type: Conference Paper
Times cited : (7)

References (20)
  • 1
    • 0035312805 scopus 로고    scopus 로고
    • Comparison of dose distributions of proton and photon beams in stereotactic conformal radiotherapy of brain lesions
    • Baumert BG, Lomax AJ, Miltchev V, et al: Comparison of dose distributions of proton and photon beams in stereotactic conformal radiotherapy of brain lesions. Int J Radiat Oncol Biol Phys 49:1439-1449, 2001
    • (2001) Int J Radiat Oncol Biol Phys , vol.49 , pp. 1439-1449
    • Baumert, B.G.1    Lomax, A.J.2    Miltchev, V.3
  • 2
    • 0034433344 scopus 로고    scopus 로고
    • A quality factor to compare the dosimetry of gamma knife radiosurgery and intensity-modulated radiation therapy quantitatively as a function of target volume and shape
    • Bordon JA, Mahajan A, Tsai JS: A quality factor to compare the dosimetry of gamma knife radiosurgery and intensity-modulated radiation therapy quantitatively as a function of target volume and shape. J Nearosurg 93 (Suppl 3):228-232, 2000
    • (2000) J Nearosurg , vol.93 , Issue.3 SUPPL. , pp. 228-232
    • Bordon, J.A.1    Mahajan, A.2    Tsai, J.S.3
  • 3
    • 0032803373 scopus 로고    scopus 로고
    • Proton radiation therapy (PRT) for pediatric optic pathway gliomas: Comparison with 3D planned conventional photons and a standard photon technique
    • Fuss M, Hug EB, Schaefer RA, et al: Proton radiation therapy (PRT) for pediatric optic pathway gliomas: comparison with 3D planned conventional photons and a standard photon technique. Int J Radiat Oncol Biol Phys 45:1117-1126, 1999
    • (1999) Int J Radiat Oncol Biol Phys , vol.45 , pp. 1117-1126
    • Fuss, M.1    Hug, E.B.2    Schaefer, R.A.3
  • 6
    • 0032842143 scopus 로고    scopus 로고
    • Comparison of intensity-modulated tomotherapy with stereotactically guided conformal radiotherapy for brain tumors
    • Khoo VS, Oldham M, Adams EJ: Comparison of intensity-modulated tomotherapy with stereotactically guided conformal radiotherapy for brain tumors. Int J Radiat Oncol Biol Phys 45:415-425, 1999
    • (1999) Int J Radiat Oncol Biol Phys , vol.45 , pp. 415-425
    • Khoo, V.S.1    Oldham, M.2    Adams, E.J.3
  • 7
    • 17144451998 scopus 로고    scopus 로고
    • Volumetric and dosimetric evaluation of radiation treatment plans: Radiation conformity index
    • Knöös T, Kristensen I, Nilsson P: Volumetric and dosimetric evaluation of radiation treatment plans: Radiation conformity index. Int J Radiat Oncol Biol Phys 42:1169-1176, 1998
    • (1998) Int J Radiat Oncol Biol Phys , vol.42 , pp. 1169-1176
    • Knöös, T.1    Kristensen, I.2    Nilsson, P.3
  • 9
    • 0032806010 scopus 로고    scopus 로고
    • A new tool for dose conformity evaluation of radiosurgery treatment plans
    • Leung LHT, Chua DTT, Wu PM: A new tool for dose conformity evaluation of radiosurgery treatment plans. Int J Radiat Oncol Biol Phys 45:233-241, 1999
    • (1999) Int J Radiat Oncol Biol Phys , vol.45 , pp. 233-241
    • Leung, L.H.T.1    Chua, D.T.T.2    Wu, P.M.3
  • 10
    • 0037376504 scopus 로고    scopus 로고
    • Quantifying the degree of conformity in radiosurgery treatment planning
    • Lomax NJ, Scheib SG: Quantifying the degree of conformity in radiosurgery treatment planning. Int J Radiat Oncol Biol Phys 55:1409-1419, 2003
    • (2003) Int J Radiat Oncol Biol Phys , vol.55 , pp. 1409-1419
    • Lomax, N.J.1    Scheib, S.G.2
  • 11
    • 0035576689 scopus 로고    scopus 로고
    • Dose conformity of gamma knife radiosurgery and risk factors for complications
    • Nakamura JL, Verhey LJ, Smith V, et al: Dose conformity of gamma knife radiosurgery and risk factors for complications. Int J Radiat Oncol Biol Phys 51:1313-1319, 2001
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 1313-1319
    • Nakamura, J.L.1    Verhey, L.J.2    Smith, V.3
  • 12
    • 0027278033 scopus 로고
    • Dynamic field shaping for stereotactic radiosurgery: A modelling study
    • Nedzi LA, Kooy HM, Alexander ED, et al: Dynamic field shaping for stereotactic radiosurgery: a modelling study. Int J Radiat Oncol Biol Phys 25:859-869, 1993
    • (1993) Int J Radiat Oncol Biol Phys , vol.25 , pp. 859-869
    • Nedzi, L.A.1    Kooy, H.M.2    Alexander, E.D.3
  • 13
    • 0034433104 scopus 로고    scopus 로고
    • Simple scoring ratio to index the conformity of radiosurgical treatment plans
    • Paddick I: Simple scoring ratio to index the conformity of radiosurgical treatment plans. J Neurosurg 93 (Suppl 3):219-222, 2000
    • (2000) J Neurosurg , vol.93 , Issue.3 SUPPL. , pp. 219-222
    • Paddick, I.1
  • 14
    • 0345257803 scopus 로고    scopus 로고
    • Isodosimetric comparison of photon stereotactic radiosurgery techniques (gamma knife vs. micromultileaf collimator linear accelerator) for acoustic neuroma - and potential clinical importance
    • Perks JR, St. George EJ, El Hamri K, et al: Isodosimetric comparison of photon stereotactic radiosurgery techniques (gamma knife vs. micromultileaf collimator linear accelerator) for acoustic neuroma - and potential clinical importance. Int J Radiat Oncol Biol Phys 57:1450-1459, 2003
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 1450-1459
    • Perks, J.R.1    St. George, E.J.2    El Hamri, K.3
  • 15
    • 0027495696 scopus 로고
    • Radiation Therapy Oncology Group: Radiosurgery quality assurance guidelines
    • Shaw E, Kline R, Gillin M, et al: Radiation Therapy Oncology Group: radiosurgery quality assurance guidelines. Int J Radiat Oncol Biol Phys 27:1231-1239, 1993
    • (1993) Int J Radiat Oncol Biol Phys , vol.27 , pp. 1231-1239
    • Shaw, E.1    Kline, R.2    Gillin, M.3
  • 16
    • 0032518344 scopus 로고    scopus 로고
    • Comparison of radiosurgery treatment modalities based on complication and control probabilities
    • Smith V, Verhey L, Serago CF: Comparison of radiosurgery treatment modalities based on complication and control probabilities. Int J Radiat Oncol Biol Phys 40:507-513, 1998
    • (1998) Int J Radiat Oncol Biol Phys , vol.40 , pp. 507-513
    • Smith, V.1    Verhey, L.2    Serago, C.F.3
  • 17
    • 0342617576 scopus 로고    scopus 로고
    • A confirmation number to quantify the degree of conformality in brachytherapy and external bean irradiation: Application to the prostate
    • Van't Riet A, Mak ACA, Moerland MA, et al: A confirmation number to quantify the degree of conformality in brachytherapy and external bean irradiation: Application to the prostate. Int J Radiat Oncol Biol Phys 37:731-736, 1997
    • (1997) Int J Radiat Oncol Biol Phys , vol.37 , pp. 731-736
    • Van't Riet, A.1    Mak, A.C.A.2    Moerland, M.A.3
  • 18
    • 0032518343 scopus 로고    scopus 로고
    • Comparison of radiosurgery treatment modalities based on physical dose distributions
    • Verhey LJ, Smith V, Serago CF: Comparison of radiosurgery treatment modalities based on physical dose distributions. Int J Radiat Oncol Biol Phys 40:497-505, 1998
    • (1998) Int J Radiat Oncol Biol Phys , vol.40 , pp. 497-505
    • Verhey, L.J.1    Smith, V.2    Serago, C.F.3
  • 19
    • 0142155548 scopus 로고    scopus 로고
    • A simple and reliable index for scoring rival stereotactic radiosurgery plans
    • Wagner TH, Bova FJ, Friedman WA, et al: A simple and reliable index for scoring rival stereotactic radiosurgery plans. Int J Radiat Oncol Biol Phys 57:1141-1149, 2003
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 1141-1149
    • Wagner, T.H.1    Bova, F.J.2    Friedman, W.A.3
  • 20
    • 7244227802 scopus 로고    scopus 로고
    • Quality of coverage: Conformity measures for stereotactic radiosurgery
    • Wu QRJ, Wessels BW, Einstein DB, et al: Quality of coverage: conformity measures for stereotactic radiosurgery. J Appl Clin Med Phys 4:374-381, 2003
    • (2003) J Appl Clin Med Phys , vol.4 , pp. 374-381
    • Wu, Q.R.J.1    Wessels, B.W.2    Einstein, D.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.