메뉴 건너뛰기




Volumn 54, Issue 22, 2009, Pages 7025-7044

Quantifying effective magnetic moments of narrow cylindrical objects in MRI

Author keywords

[No Author keywords available]

Indexed keywords

ALIASING EFFECTS; CROSS SECTION; CYLINDRICAL OBJECTS; DEPHASING; ECHO TIME; EFFECTIVE MAGNETIC MOMENTS; ERROR PROPAGATION METHODS; GRADIENT ECHO SEQUENCES; PARTIAL VOLUMES; SUB PIXELS;

EID: 72249106042     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/54/22/018     Document Type: Article
Times cited : (14)

References (12)
  • 2
    • 34648816740 scopus 로고    scopus 로고
    • A complex sum method of quantifying susceptibilities in cylindrical objects: The first step toward quantitative diagnosis of small objects in MRI
    • Cheng Y-C N, Hsieh C-Y, Neelavalli J, Liu Q, Dawood M S and Haacke E M 2007 A complex sum method of quantifying susceptibilities in cylindrical objects: the first step toward quantitative diagnosis of small objects in MRI Magn. Reson. Imaging 25 1171-80
    • (2007) Magn. Reson. Imaging , vol.25 , Issue.8 , pp. 1171-1180
    • Cheng -C Y, N.1    Hsieh, C.-Y.2    Neelavalli, J.3    Liu, Q.4    Dawood, M.S.5    Haacke, E.M.6
  • 7
    • 0027265576 scopus 로고
    • Identification of vascular structures as a major source of signal contrast in high resolution 2D and 3D functional activation imaging of the motor cortex at 1.5 T: Preliminary results
    • Lai S, Hopkins A L, Haacke E M, Li D, Wasserman B A, Buckley P, Friedman L, Meltzer H, Hedera P and Friedland R 1993 Identification of vascular structures as a major source of signal contrast in high resolution 2D and 3D functional activation imaging of the motor cortex at 1.5 T: preliminary results Magn. Reson. Med. 30 387-92
    • (1993) Magn. Reson. Med. , vol.30 , Issue.3 , pp. 387-392
    • Lai, S.1    Hopkins, A.L.2    Haacke, E.M.3    Li, D.4    Wasserman, B.A.5    Buckley, P.6    Friedman, L.7    Meltzer, H.8    Hedera, P.9    Friedland, R.10
  • 10
    • 21144440431 scopus 로고    scopus 로고
    • Identifying particles in industrial systems using MRI susceptibility artifacts
    • Robson P and Hall L 2005 Identifying particles in industrial systems using MRI susceptibility artifacts Am. Inst. Chem. Eng. 51 1633-40
    • (2005) Am. Inst. Chem. Eng. , vol.51 , pp. 1633-1640
    • Robson, P.1    Hall, L.2
  • 11
    • 35948961164 scopus 로고    scopus 로고
    • Obtaining blood oxygenation levels from MR signal behavior in the presence of single venous vessels
    • Sedlacik J, Rauscher A and Reichenbach J R 2007 Obtaining blood oxygenation levels from MR signal behavior in the presence of single venous vessels Magn. Reson. Med. 58 1035-44
    • (2007) Magn. Reson. Med. , vol.58 , Issue.5 , pp. 1035-1044
    • Sedlacik, J.1    Rauscher, A.2    Reichenbach, J.R.3
  • 12
    • 0026520830 scopus 로고
    • MRI susceptometry: Image-based measurement of absolute susceptibility of MR contrast agent and human blood
    • Weisskoff R M and Kiihne S 1992 MRI susceptometry: image-based measurement of absolute susceptibility of MR contrast agent and human blood Magn. Reson. Med. 24 375-83
    • (1992) Magn. Reson. Med. , vol.24 , Issue.2 , pp. 375-383
    • Weisskoff, R.M.1    Kiihne, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.