메뉴 건너뛰기




Volumn 21, Issue 8, 2009, Pages 574-578

Preoxygenation by 8 deep breaths in 60 seconds using the Mapleson A (Magill), the circle system, or the Mapleson D system

Author keywords

Anesthesia systems; Eight deep breaths in sixty seconds; Fractional end tidaloxygen concentration; Oxygen flow; Preoxygenation

Indexed keywords

OXYGEN;

EID: 72149132056     PISSN: 09528180     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jclinane.2009.01.013     Document Type: Article
Times cited : (5)

References (9)
  • 1
    • 0032871393 scopus 로고    scopus 로고
    • Preoxygenation: comparison of maximal breathing and tidal volume breathing techniques
    • Baraka A., Taha S., Aouad M., El-Khatib M., and Kawkabani N. Preoxygenation: comparison of maximal breathing and tidal volume breathing techniques. Anesthesiology 91 (1999) 612-616
    • (1999) Anesthesiology , vol.91 , pp. 612-616
    • Baraka, A.1    Taha, S.2    Aouad, M.3    El-Khatib, M.4    Kawkabani, N.5
  • 2
    • 0032847134 scopus 로고    scopus 로고
    • Preoxygenation: best method for both efficacy and efficiency? (Editorial)
    • Benumof J. Preoxygenation: best method for both efficacy and efficiency? (Editorial). Anesthesiology 91 (1999) 603-605
    • (1999) Anesthesiology , vol.91 , pp. 603-605
    • Benumof, J.1
  • 3
    • 33947730393 scopus 로고    scopus 로고
    • Preoxygenation with Mapleson D anesthetic circuit requires higher oxygen flows than with Mapleson A or circle circuits
    • Taha S., El-Khatib M., Siddik-Sayyid S., Dagher C., Chehade J.M., and Baraka A. Preoxygenation with Mapleson D anesthetic circuit requires higher oxygen flows than with Mapleson A or circle circuits. Can J Anaesth 54 (2007) 141-145
    • (2007) Can J Anaesth , vol.54 , pp. 141-145
    • Taha, S.1    El-Khatib, M.2    Siddik-Sayyid, S.3    Dagher, C.4    Chehade, J.M.5    Baraka, A.6
  • 4
    • 0000254531 scopus 로고
    • The elimination of rebreathing in various semi-closed anaesthetic systems
    • Mapleson W. The elimination of rebreathing in various semi-closed anaesthetic systems. Br J Anaesth 26 (1954) 323-332
    • (1954) Br J Anaesth , vol.26 , pp. 323-332
    • Mapleson, W.1
  • 6
    • 0002338544 scopus 로고
    • Distribution of pulmonary ventilation and perfusion
    • Nunn J.F. (Ed), Butterworths-Heinemann, Ltd, Oxford
    • th ed (1993), Butterworths-Heinemann, Ltd, Oxford 140-183
    • (1993) th ed , pp. 140-183
    • Nunn, J.F.1
  • 7
    • 0014526835 scopus 로고
    • 2 control by fresh gas flow during controlled ventilation with a semi-open circuit
    • 2 control by fresh gas flow during controlled ventilation with a semi-open circuit. Br J Anaesth 41 (1969) 527-529
    • (1969) Br J Anaesth , vol.41 , pp. 527-529
    • Baraka, A.1
  • 8
    • 70449199868 scopus 로고
    • Theoretical considerations of the effects of rebreathing in two semi-closed anaesthetic systems
    • Mapleson W. Theoretical considerations of the effects of rebreathing in two semi-closed anaesthetic systems. Br Med Bull 14 (1958) 64-68
    • (1958) Br Med Bull , vol.14 , pp. 64-68
    • Mapleson, W.1
  • 9
    • 8944253919 scopus 로고
    • Inspired gas, rebreathing and apparatus dead space
    • Nunn J.F., and Newman H.C. Inspired gas, rebreathing and apparatus dead space. Br J Anaesth 36 (1964) 5-10
    • (1964) Br J Anaesth , vol.36 , pp. 5-10
    • Nunn, J.F.1    Newman, H.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.