메뉴 건너뛰기




Volumn 36, Issue 1, 2010, Pages 53-57

Real-time intraocular pressure measurement in standard and microcoaxial phacoemulsification

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; CATARACT EXTRACTION; CILIARY DISK; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED STUDY; FEMALE; GERMANY; HUMAN; INTRAOCULAR PRESSURE; LENS IMPLANT; MALE; PHACOEMULSIFICATION; PRESSURE TRANSDUCER; PRIORITY JOURNAL; VITRECTOMY; VITREOUS BODY;

EID: 72049113822     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2009.07.035     Document Type: Article
Times cited : (21)

References (7)
  • 1
    • 0026552260 scopus 로고
    • Direct intraoperative continuous monitoring of intraocular pressure
    • Blumenthal M., Cahane M., and Ashkenazi I. Direct intraoperative continuous monitoring of intraocular pressure. Ophthalmic Surg 23 (1992) 132-134
    • (1992) Ophthalmic Surg , vol.23 , pp. 132-134
    • Blumenthal, M.1    Cahane, M.2    Ashkenazi, I.3
  • 2
    • 77949848482 scopus 로고    scopus 로고
    • Comparison of intraocular pressure profiles during cataract surgery by phacoemulsification and extracapsular cataract extraction
    • Grinbaum A., Blumenthal M., and Assia E. Comparison of intraocular pressure profiles during cataract surgery by phacoemulsification and extracapsular cataract extraction. Ophthalmic Surg Lasers Imaging 34 (2003) 182-186
    • (2003) Ophthalmic Surg Lasers Imaging , vol.34 , pp. 182-186
    • Grinbaum, A.1    Blumenthal, M.2    Assia, E.3
  • 3
    • 0032840421 scopus 로고    scopus 로고
    • Mehr als vier Jahre Erfahrung mit der elektronischen intraokularen Nadel-Druckmessung bei irregulären Hornhäuten. [More than 4 years' experience with electronic intraocular needle tonometry]
    • Marx W., Madjlessi F., Reinhard T., Althaus C., and Sundmacher R. Mehr als vier Jahre Erfahrung mit der elektronischen intraokularen Nadel-Druckmessung bei irregulären Hornhäuten. [More than 4 years' experience with electronic intraocular needle tonometry]. Ophthalmologe 96 (1999) 498-502
    • (1999) Ophthalmologe , vol.96 , pp. 498-502
    • Marx, W.1    Madjlessi, F.2    Reinhard, T.3    Althaus, C.4    Sundmacher, R.5
  • 4
    • 0022571165 scopus 로고
    • Variations in intraocular pressure during closed-system surgical procedures
    • Moorhead L.C., and Armeniades C.D. Variations in intraocular pressure during closed-system surgical procedures. Arch Ophthalmol 104 (1986) 269-272
    • (1986) Arch Ophthalmol , vol.104 , pp. 269-272
    • Moorhead, L.C.1    Armeniades, C.D.2
  • 5
    • 0023235973 scopus 로고
    • An intraoperative intraocular pressure monitor
    • Parel J.-M., Parrish II R., and Nose I. An intraoperative intraocular pressure monitor. Ophthalmic Surg 18 (1987) 371-374
    • (1987) Ophthalmic Surg , vol.18 , pp. 371-374
    • Parel, J.-M.1    Parrish II, R.2    Nose, I.3
  • 6
    • 0027275427 scopus 로고
    • Evaluation of intraocular pressure fluctuations with differing phacoemulsification approaches
    • Wilbrandt H.R., and Wilbrandt T.H. Evaluation of intraocular pressure fluctuations with differing phacoemulsification approaches. J Cataract Refract Surg 19 (1993) 223-231
    • (1993) J Cataract Refract Surg , vol.19 , pp. 223-231
    • Wilbrandt, H.R.1    Wilbrandt, T.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.