메뉴 건너뛰기




Volumn 25, Issue 7, 2009, Pages 554-565

Design of a water coupling bolus with improved flow distribution for multi-element superficial hyperthermia applicators

Author keywords

Chest wall recurrence; Flow distribution; Hyperthermia; Superficial disease; Water bolus

Indexed keywords

WATER;

EID: 72049113334     PISSN: 02656736     EISSN: 14645157     Source Type: Journal    
DOI: 10.3109/02656730903124506     Document Type: Article
Times cited : (16)

References (41)
  • 2
    • 0029782959 scopus 로고    scopus 로고
    • Efficacy of adjuvant hyperthermia in the treatment of superficial recurrent breast cancer: Confirmation and future directions
    • Kapp DS. Efficacy of adjuvant hyperthermia in the treatment of superficial recurrent breast cancer: Confirmation and future directions. Int J Radiat Oncol, Biol Phys 1996;35:1117-1121.
    • (1996) Int J Radiat Oncol, Biol Phys , vol.35 , pp. 1117-1121
    • Kapp, D.S.1
  • 6
    • 0019208702 scopus 로고
    • Simultaneous and sequential hyperthermia and radiation treatment of an experimental tumor and its surrounding normal tissue in vivo
    • Overgaard J. Simultaneous and sequential hyperthermia and radiation treatment of an experimental tumor and its surrounding normal tissue in vivo. Int J Radiat Oncol Biol Phys 1980;6:1507-1517.
    • (1980) Int J Radiat Oncol Biol Phys , vol.6 , pp. 1507-1517
    • Overgaard, J.1
  • 7
    • 0024602937 scopus 로고
    • The current and potential role of hyperthermia in radiotherapy
    • Overgaard J. The current and potential role of hyperthermia in radiotherapy. Int J Radiat Oncol Biol Phys 1989;16: 535-549.
    • (1989) Int J Radiat Oncol Biol Phys , vol.16 , pp. 535-549
    • Overgaard, J.1
  • 8
    • 33750557008 scopus 로고    scopus 로고
    • Multilayer conformal applicator for microwave heating and brachytherapy treatment of superficial tissue disease
    • Juang T, Stauffer PR, Neuman DG, Schlorff J. Multilayer conformal applicator for microwave heating and brachytherapy treatment of superficial tissue disease. Int J Hyperthermia 2006;22:527-544.
    • (2006) Int J Hyperthermia , vol.22 , pp. 527-544
    • Juang, T.1    Stauffer, P.R.2    Neuman, D.G.3    Schlorff, J.4
  • 9
    • 0028944536 scopus 로고
    • Simultaneous delivery of electron beam therapy and ultrasound hyperthermia utilizing scanning reflectors: A feasibility study
    • Moros EG, Straube WL, Klein EE, Yousaf M, Myerson RJ. Simultaneous delivery of electron beam therapy and ultrasound hyperthermia utilizing scanning reflectors: A feasibility study. Int J Radiat Oncol Biol Phys 1995;31:893-904.
    • (1995) Int J Radiat Oncol Biol Phys , vol.31 , pp. 893-904
    • Moros, E.G.1    Straube, W.L.2    Klein, E.E.3    Yousaf, M.4    Myerson, R.J.5
  • 10
    • 0032773531 scopus 로고    scopus 로고
    • Simultaneous superficial hyperthermia and external radiotherapy: Report of thermal dosimetry and tolerance to treatment
    • Myerson RJ, Straube WL, Moros EG, Emami BN, Lee HK, Perez CA, Taylor ME. Simultaneous superficial hyperthermia and external radiotherapy: Report of thermal dosimetry and tolerance to treatment. Int J Hyperthermia 1999;15:251-266.
    • (1999) Int J Hyperthermia , vol.15 , pp. 251-266
    • Myerson, R.J.1    Straube, W.L.2    Moros, E.G.3    Emami, B.N.4    Lee, H.K.5    Perez, C.A.6    Taylor, M.E.7
  • 11
    • 12844257366 scopus 로고    scopus 로고
    • SURLAS: A new clinical grade ultrasound system for sequential or concomitant thermoradiotherapy of superficial tumors: Applicator description
    • Novak P, Moros EG, Straube WL, Myerson RJ. SURLAS: A new clinical grade ultrasound system for sequential or concomitant thermoradiotherapy of superficial tumors: Applicator description. Med Phys 2005;32:230-240.
    • (2005) Med Phys , vol.32 , pp. 230-240
    • Novak, P.1    Moros, E.G.2    Straube, W.L.3    Myerson, R.J.4
  • 12
    • 0035175969 scopus 로고    scopus 로고
    • Dosimetry and techniques for simultaneous hyperthermia and external beam radiation therapy
    • Straube WL, Klein EE, Moros EG, Low DA, Myerson RJ. Dosimetry and techniques for simultaneous hyperthermia and external beam radiation therapy. Int J Hyperthermia 2001;17:48-62.
    • (2001) Int J Hyperthermia , vol.17 , pp. 48-62
    • Straube, W.L.1    Klein, E.E.2    Moros, E.G.3    Low, D.A.4    Myerson, R.J.5
  • 13
  • 16
    • 65949123778 scopus 로고    scopus 로고
    • Progress on thermobrachytherapy surface applicator for superficial tissue disease, Energy-based Treatment of Tissue and Assessment v
    • Arunachalam K, Craciunescu OI, Maccarini PF, Schlorff JL, Markowitz E, Stauffer PR. Progress on thermobrachytherapy surface applicator for superficial tissue disease, Energy-based Treatment of Tissue and Assessment V. Proceedings SPIE 2009;7181:71810C-71810C-12.
    • (2009) Proceedings SPIE , vol.7181
    • Arunachalam, K.1    Craciunescu, O.I.2    MacCarini, P.F.3    Schlorff, J.L.4    Markowitz, E.5    Stauffer, P.R.6
  • 17
    • 0034001826 scopus 로고    scopus 로고
    • Thermal and SAR characterization of multielement dual concentric conductor microwave applicators for hyperthermia: A theoretical investigation
    • Rossetto F, Diederich CJ, Stauffer PR. Thermal and SAR characterization of multielement dual concentric conductor microwave applicators for hyperthermia: A theoretical investigation. Med Phys 2000;27:745-753.
    • (2000) Med Phys , vol.27 , pp. 745-753
    • Rossetto, F.1    Diederich, C.J.2    Stauffer, P.R.3
  • 18
    • 0028008523 scopus 로고
    • Influence of water bolus temperature on measured skin surface and intradermal temperatures
    • Lee ER, Kapp DS, Lohrbach AW, Sokol JL. Influence of water bolus temperature on measured skin surface and intradermal temperatures. Int J Hyperthermia 1994;10:59-72.
    • (1994) Int J Hyperthermia , vol.10 , pp. 59-72
    • Lee, E.R.1    Kapp, D.S.2    Lohrbach, A.W.3    Sokol, J.L.4
  • 19
    • 0028973445 scopus 로고
    • FDTD simulations of Clini-Therm applicators on inhomogeneous planar tissue models
    • Chan KW, McDougall JA, Chou CK. FDTD simulations of Clini-Therm applicators on inhomogeneous planar tissue models. Int J Hyperthermia 1995;11:809-820.
    • (1995) Int J Hyperthermia , vol.11 , pp. 809-820
    • Chan, K.W.1    McDougall, J.A.2    Chou, C.K.3
  • 21
    • 31544474900 scopus 로고    scopus 로고
    • Effects of water bolus size, shape and configuration on the SAR distribution pattern of the Lucite cone applicator
    • De Bruijne M, Samaras T, Bakker JF, Van Rhoon GC. Effects of water bolus size, shape and configuration on the SAR distribution pattern of the Lucite cone applicator. Int J Hyperthermia 2006;22:15-28.
    • (2006) Int J Hyperthermia , vol.22 , pp. 15-28
    • De Bruijne, M.1    Samaras, T.2    Bakker, J.F.3    Van Rhoon, G.C.4
  • 23
    • 0027978410 scopus 로고
    • A variable microwave array attenuator for use with singleelement waveguide applicators
    • Sherar MD, Clark H, Cooper B, Kumaradas J, Liu FF. A variable microwave array attenuator for use with singleelement waveguide applicators. Int J Hyperthermia 1994;10:723-731.
    • (1994) Int J Hyperthermia , vol.10 , pp. 723-731
    • Sherar, M.D.1    Clark, H.2    Cooper, B.3    Kumaradas, J.4    Liu, F.F.5
  • 25
    • 0027937091 scopus 로고
    • An improved bolus configuration for commercial multielement ultrasound and microwave hyperthermia systems
    • Diederich CJ, Stauffer PR, Bozzo D. An improved bolus configuration for commercial multielement ultrasound and microwave hyperthermia systems. Med Phys 1994;21: 1401-1403.
    • (1994) Med Phys , vol.21 , pp. 1401-1403
    • Diederich, C.J.1    Stauffer, P.R.2    Bozzo, D.3
  • 26
    • 0036721508 scopus 로고    scopus 로고
    • Contact flexible microstrip applicators (CFMA) in a range from microwaves up to short waves
    • Gelvich EA, Mazokhin VN. Contact flexible microstrip applicators (CFMA) in a range from microwaves up to short waves. IEEE Trans Biomed Eng 2002;49:1015-1023.
    • (2002) IEEE Trans Biomed Eng , vol.49 , pp. 1015-1023
    • Gelvich, E.A.1    Mazokhin, V.N.2
  • 27
    • 0036269544 scopus 로고    scopus 로고
    • SAR pattern perturbations from resonance effects in water bolus layers used with superficial microwave hyperthermia applicators
    • Newman DG, Diederich CJ, Stauffer PR, Bozzo D. SAR pattern perturbations from resonance effects in water bolus layers used with superficial microwave hyperthermia applicators. Int J Hyperthermia 2002;18:180-193.
    • (2002) Int J Hyperthermia , vol.18 , pp. 180-193
    • Newman, D.G.1    Diederich, C.J.2    Stauffer, P.R.3    Bozzo, D.4
  • 28
    • 0032709811 scopus 로고    scopus 로고
    • Effect of complex bolus-tissue load configurations on SAR distributions from dual concentric conductor applicators
    • Rossetto F, Stauffer PR. Effect of complex bolus-tissue load configurations on SAR distributions from dual concentric conductor applicators. IEEE Trans Biomed Eng 1999;46: 1310-1319.
    • (1999) IEEE Trans Biomed Eng , vol.46 , pp. 1310-1319
    • Rossetto, F.1    Stauffer, P.R.2
  • 29
    • 0031744072 scopus 로고    scopus 로고
    • Effect of practical layered dielectric loads on SAR patterns from dual concentric conductor microstrip antennas
    • Rossetto F, Stauffer PR, Manfrini V, Diederich CJ, Biffi GG. Effect of practical layered dielectric loads on SAR patterns from dual concentric conductor microstrip antennas. Int J Hyperthermia 1998;14:513-534.
    • (1998) Int J Hyperthermia , vol.14 , pp. 513-534
    • Rossetto, F.1    Stauffer, P.R.2    Manfrini, V.3    Diederich, C.J.4    Biffi, G.G.5
  • 30
    • 84961244694 scopus 로고    scopus 로고
    • Thermal therapy techniques for skin and superficial tissue disease
    • Ryan TP, editor. Bellingham, WA: SPIE Optical Engineering Press
    • Stauffer PR. Thermal therapy techniques for skin and superficial tissue disease. In: Ryan TP, editor. A Critical Review, Matching the Energy Source to the Clinical Need, Vol.CR75. Bellingham, WA: SPIE Optical Engineering Press; 2000. pp 327-367.
    • (2000) A Critical Review, Matching the Energy Source to the Clinical Need , vol.CR75 , pp. 327-367
    • Stauffer, P.R.1
  • 31
    • 70249133005 scopus 로고    scopus 로고
    • Flow patterns and heat convection in a rectangular water bolus for use in superficial hyperthermia
    • Birkelund Y, Jacobsen S, Arunachalam K, Maccarini P, Stauffer PR. Flow patterns and heat convection in a rectangular water bolus for use in superficial hyperthermia. Phys Med Biol 2009;54:3937-3953.
    • (2009) Phys Med Biol , vol.54 , pp. 3937-3953
    • Birkelund, Y.1    Jacobsen, S.2    Arunachalam, K.3    MacCarini, P.4    Stauffer, P.R.5
  • 32
    • 84992342204 scopus 로고
    • A model for flow distribution in manifolds
    • Baijura RA. A model for flow distribution in manifolds. J Eng power 1971;93:7-12.
    • (1971) J Eng Power , vol.93 , pp. 7-12
    • Baijura, R.A.1
  • 33
    • 0034996302 scopus 로고    scopus 로고
    • Analysis of manifold fluid flow networks for air and liquid flow through modular electronics
    • IEEE
    • Johnson ST. Analysis of manifold fluid flow networks for air and liquid flow through modular electronics. In: Seventeenth IEEE SEMI-THERM symposium. 2001: IEEE.
    • (2001) Seventeenth IEEE SEMI-THERM Symposium
    • Johnson, S.T.1
  • 34
    • 0019231372 scopus 로고
    • Flow distribution in parallel and reverse flow manifolds
    • Datta AB, Majumdar AK. Flow distribution in parallel and reverse flow manifolds. Int J Heat Fluid Flow 1980;2:253-262.
    • (1980) Int J Heat Fluid Flow , vol.2 , pp. 253-262
    • Datta, A.B.1    Majumdar, A.K.2
  • 37
    • 84867158764 scopus 로고
    • The uniform distribution of a fluid flowing through a perforated pipe
    • Dow WM. The uniform distribution of a fluid flowing through a perforated pipe. J Applied Mech, Trans ASME 1950;72:431-438.
    • (1950) J Applied Mech, Trans ASME , vol.72 , pp. 431-438
    • Dow, W.M.1
  • 38
    • 0012795557 scopus 로고
    • On the characterization of divided flow and confluent flow in headers
    • Kubo T, Ueda T. On the characterization of divided flow and confluent flow in headers. Bull Jap Soc Mech Eng 1969; 12:802-809.
    • (1969) Bull Jap Soc Mech Eng , vol.12 , pp. 802-809
    • Kubo, T.1    Ueda, T.2
  • 40
    • 33645802415 scopus 로고    scopus 로고
    • Interfacial conditions between a pure fluid and a porous medium: Implications for binary alloy solidification
    • Bars ML, Worster MG. Interfacial conditions between a pure fluid and a porous medium: Implications for binary alloy solidification. J Fluid Mech 2006;550:149-173.
    • (2006) J Fluid Mech , vol.550 , pp. 149-173
    • Bars, M.L.1    Worster, M.G.2
  • 41
    • 0027927079 scopus 로고
    • A determination of effective viscosity for the Brinkman-Forchheimer flow model
    • Givler RC, Altobelli SA. A determination of effective viscosity for the Brinkman-Forchheimer flow model. J Fluid Mech 1994;258:355-370.
    • (1994) J Fluid Mech , vol.258 , pp. 355-370
    • Givler, R.C.1    Altobelli, S.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.