메뉴 건너뛰기




Volumn 62, Issue 11, 2009, Pages 1519-1523

Use of the slit arteriotomy for end-to-side arterial anastomosis in free-tissue transfers to the extremities

Author keywords

Advantages; Clinical experience; Microsurgery; Outcome; Simulation model; Technique

Indexed keywords

ANTEROLATERAL THIGH FLAP; ARTERIOTOMY; ARTERY ANASTOMOSIS; ARTICLE; COMPUTER SIMULATION; CONTROLLED STUDY; END TO END ANASTOMOSIS; FIBULA GRAFT; FINITE ELEMENT ANALYSIS; FREE TISSUE GRAFT; HUMAN; LATERAL ARM FLAP; LATISSIMUS DORSI FLAP; MAJOR CLINICAL STUDY; MUSCLE FLAP; PRIORITY JOURNAL; RADIAL FOREARM FLAP; REVASCULARIZATION; TREATMENT OUTCOME; VASCULAR PATENCY;

EID: 72049096657     PISSN: 17486815     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.bjps.2008.05.016     Document Type: Article
Times cited : (25)

References (17)
  • 1
    • 0018630021 scopus 로고
    • Preferential use of end-to-side arterial anastomoses in free flap transfers
    • Godina M. Preferential use of end-to-side arterial anastomoses in free flap transfers. Plast Reconstr Surg 64 (1979 Nov) 673-682
    • (1979) Plast Reconstr Surg , vol.64 , pp. 673-682
    • Godina, M.1
  • 2
    • 0030939980 scopus 로고    scopus 로고
    • A clinical study of end-to-end versus end-to-side techniques for microvascular anastomosis
    • Samaha F.J., Oliva A., Buncke G.M., et al. A clinical study of end-to-end versus end-to-side techniques for microvascular anastomosis. Plast Reconstr Surg 99 (1997 Apr) 1109-1111
    • (1997) Plast Reconstr Surg , vol.99 , pp. 1109-1111
    • Samaha, F.J.1    Oliva, A.2    Buncke, G.M.3
  • 3
    • 0031782522 scopus 로고    scopus 로고
    • End-to-end versus end-to-side arterial anastomosis patency in microvascular surgery
    • Dotson R.J., Bishop A.T., Wood M.B., et al. End-to-end versus end-to-side arterial anastomosis patency in microvascular surgery. Microsurgery 18 (1998) 125-128
    • (1998) Microsurgery , vol.18 , pp. 125-128
    • Dotson, R.J.1    Bishop, A.T.2    Wood, M.B.3
  • 4
    • 0018137605 scopus 로고
    • An experimental study of end-to-side microvascular anastomosis
    • Nam D.A., Roberts III T.L., and Acland R.D. An experimental study of end-to-side microvascular anastomosis. Surg Gynecol Obstet 147 (1978) 339
    • (1978) Surg Gynecol Obstet , vol.147 , pp. 339
    • Nam, D.A.1    Roberts III, T.L.2    Acland, R.D.3
  • 5
    • 0026729989 scopus 로고
    • Hemodynamic and histological differences in end-to-side anastomoses
    • Zoubos A.B., Seaber A.V., and Urbaniak J.R. Hemodynamic and histological differences in end-to-side anastomoses. Microsurgery 13 (1992) 200
    • (1992) Microsurgery , vol.13 , pp. 200
    • Zoubos, A.B.1    Seaber, A.V.2    Urbaniak, J.R.3
  • 6
    • 33645786729 scopus 로고    scopus 로고
    • Simple and reliable procedure for end-to-side microvascular anastomosis: the diamond technique
    • Sen C., Agir H., and Iscen D. Simple and reliable procedure for end-to-side microvascular anastomosis: the diamond technique. Microsurgery 26 (2006) 160-164
    • (2006) Microsurgery , vol.26 , pp. 160-164
    • Sen, C.1    Agir, H.2    Iscen, D.3
  • 7
    • 17044400586 scopus 로고    scopus 로고
    • How to deal with difficult microsurgical end-to-side anastomoses
    • Verhelle N.A., and Heymans O. How to deal with difficult microsurgical end-to-side anastomoses. Microsurgery 25 (2005) 203-208
    • (2005) Microsurgery , vol.25 , pp. 203-208
    • Verhelle, N.A.1    Heymans, O.2
  • 8
    • 0019253836 scopus 로고
    • End-to-side anastomoses: a model and a technique with clinical application
    • Hall E.J. End-to-side anastomoses: a model and a technique with clinical application. J Microsurg 2 (1980 Dec) 106-112
    • (1980) J Microsurg , vol.2 , pp. 106-112
    • Hall, E.J.1
  • 9
    • 0027242065 scopus 로고
    • A simple arteriotomy method for microsurgical end-to-side anastomoses: technical aspects of use in training and laboratory applications
    • Dash H., Kononov A., Maloney III J., et al. A simple arteriotomy method for microsurgical end-to-side anastomoses: technical aspects of use in training and laboratory applications. J Reconstr Microsurg 9 (1993) 381
    • (1993) J Reconstr Microsurg , vol.9 , pp. 381
    • Dash, H.1    Kononov, A.2    Maloney III, J.3
  • 10
    • 0024320136 scopus 로고
    • Use of the vascular punch in microsurgery
    • Pederson W.C., and Barwick W.J. Use of the vascular punch in microsurgery. J Reconstr Microsurg 5 (1989 Apr) 115-118
    • (1989) J Reconstr Microsurg , vol.5 , pp. 115-118
    • Pederson, W.C.1    Barwick, W.J.2
  • 11
    • 0030066890 scopus 로고    scopus 로고
    • Use of a micropunch for arteriotomy in end-to-side anastomosis
    • Hallock G.G., and Rice D.C. Use of a micropunch for arteriotomy in end-to-side anastomosis. J Reconstr Microsurg 12 (1996 Jan) 59-62
    • (1996) J Reconstr Microsurg , vol.12 , pp. 59-62
    • Hallock, G.G.1    Rice, D.C.2
  • 12
    • 0033982147 scopus 로고    scopus 로고
    • Patency of different arterial and venous end-to-side microanastomosis techniques in a rat model
    • Adams Jr. W.P., Ansari M.S., Hay M.T., et al. Patency of different arterial and venous end-to-side microanastomosis techniques in a rat model. Plast Reconstr Surg 105 (2000 Jan) 156-161
    • (2000) Plast Reconstr Surg , vol.105 , pp. 156-161
    • Adams Jr., W.P.1    Ansari, M.S.2    Hay, M.T.3
  • 13
    • 0008531748 scopus 로고
    • Hemodynamic principles and end-to-side vascular anastomoses
    • Lazzarini-Robertson A.A. Hemodynamic principles and end-to-side vascular anastomoses. Arch Surg 82 (1962) 384
    • (1962) Arch Surg , vol.82 , pp. 384
    • Lazzarini-Robertson, A.A.1
  • 14
    • 2442442923 scopus 로고    scopus 로고
    • Salvage of the Massively Traumatized Lower Extremity with Sequential Free Flaps
    • Tham C., Tan B.K., Hong S.W., et al. Salvage of the Massively Traumatized Lower Extremity with Sequential Free Flaps. Plast Reconstr Surg 113 (May 2004) 1746-1750
    • (2004) Plast Reconstr Surg , vol.113 , pp. 1746-1750
    • Tham, C.1    Tan, B.K.2    Hong, S.W.3
  • 15
    • 29744462739 scopus 로고    scopus 로고
    • Nonlinear finite element simulation to elucidate the efficacy of slit arteriotomy for end-to-side arterial anastomosis in microsurgery
    • Gu H., Chua A., Tan B.K., et al. Nonlinear finite element simulation to elucidate the efficacy of slit arteriotomy for end-to-side arterial anastomosis in microsurgery. J Biomech 39 (2006) 435-443
    • (2006) J Biomech , vol.39 , pp. 435-443
    • Gu, H.1    Chua, A.2    Tan, B.K.3
  • 16
    • 14644402995 scopus 로고    scopus 로고
    • Two options for perforator flaps in the flank donor site: latissimus dorsi and thoracodorsal perforator flaps
    • Kim J.T. Two options for perforator flaps in the flank donor site: latissimus dorsi and thoracodorsal perforator flaps. Plast Reconstr Surg 115 (2005) 755-763
    • (2005) Plast Reconstr Surg , vol.115 , pp. 755-763
    • Kim, J.T.1
  • 17
    • 72049089123 scopus 로고    scopus 로고
    • www.microflap.com


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.