메뉴 건너뛰기




Volumn 138, Issue 5, 2009, Pages 1227-1233

Migration forces of transcatheter aortic valves in patients with noncalcific aortic insufficiency

Author keywords

[No Author keywords available]

Indexed keywords

AORTA ROOT; AORTA STENOSIS; AORTA VALVE; AORTA VALVE REGURGITATION; ARTICLE; DIASTOLE; DIASTOLIC BLOOD PRESSURE; DISEASE SEVERITY; DYNAMICS; FORCE; HEART EJECTION FRACTION; HEMODYNAMICS; MATHEMATICAL COMPUTING; PRIORITY JOURNAL; PROSTHESIS; SIMULATION; SYSTOLE;

EID: 72049084501     PISSN: 00225223     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jtcvs.2009.02.057     Document Type: Article
Times cited : (45)

References (25)
  • 1
    • 34250221526 scopus 로고    scopus 로고
    • Infrarenal aortic devices: failure modes and unmet needs
    • Lee W.A. Infrarenal aortic devices: failure modes and unmet needs. Semin Vasc Surg 20 (2007) 75-80
    • (2007) Semin Vasc Surg , vol.20 , pp. 75-80
    • Lee, W.A.1
  • 2
    • 0742269712 scopus 로고    scopus 로고
    • Collagen fibers reduce stresses and stabilize motion of aortic valve leaflets during systole
    • De Hart J., Peters G.W., Schreurs P.J., and Baaijens F.P. Collagen fibers reduce stresses and stabilize motion of aortic valve leaflets during systole. J Biomech 37 (2004) 303-311
    • (2004) J Biomech , vol.37 , pp. 303-311
    • De Hart, J.1    Peters, G.W.2    Schreurs, P.J.3    Baaijens, F.P.4
  • 3
    • 0032122272 scopus 로고    scopus 로고
    • A three-dimensional analysis of a fibre-reinforced aortic valve prosthesis
    • De Hart J., Cacciola G., Schreurs P.J., and Peters G.W. A three-dimensional analysis of a fibre-reinforced aortic valve prosthesis. J Biomech 31 (1998) 629-638
    • (1998) J Biomech , vol.31 , pp. 629-638
    • De Hart, J.1    Cacciola, G.2    Schreurs, P.J.3    Peters, G.W.4
  • 4
    • 0036667709 scopus 로고    scopus 로고
    • Unsteady and three-dimensional simulation of blood flow in the human aortic arch
    • Shahcheraghi N., Dwyer H.A., Cheer A.Y., Barakat A.I., and Rutaganira T. Unsteady and three-dimensional simulation of blood flow in the human aortic arch. J Biomech Eng 124 (2002) 378-387
    • (2002) J Biomech Eng , vol.124 , pp. 378-387
    • Shahcheraghi, N.1    Dwyer, H.A.2    Cheer, A.Y.3    Barakat, A.I.4    Rutaganira, T.5
  • 5
    • 2942735045 scopus 로고    scopus 로고
    • A simulated dye method for flow visualization with a computational model for blood flow
    • Kim T., Cheer A.Y., and Dwyer H.A. A simulated dye method for flow visualization with a computational model for blood flow. J Biomech 37 (2004) 1125-1136
    • (2004) J Biomech , vol.37 , pp. 1125-1136
    • Kim, T.1    Cheer, A.Y.2    Dwyer, H.A.3
  • 10
    • 0037058854 scopus 로고    scopus 로고
    • Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description
    • Cribier A., Eltchaninoff H., Bash A., Borenstein N., Tron C., Bauer F., et al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation 106 (2002) 3006-3008
    • (2002) Circulation , vol.106 , pp. 3006-3008
    • Cribier, A.1    Eltchaninoff, H.2    Bash, A.3    Borenstein, N.4    Tron, C.5    Bauer, F.6
  • 11
    • 4544254485 scopus 로고    scopus 로고
    • Acute improvement in global and regional left ventricular systolic function after percutaneous heart valve implantation in patients with symptomatic aortic stenosis
    • Bauer F., Eltchaninoff H., Tron C., Lesault P.F., Agatiello C., Nercolini D., et al. Acute improvement in global and regional left ventricular systolic function after percutaneous heart valve implantation in patients with symptomatic aortic stenosis. Circulation 110 (2004) 1473-1476
    • (2004) Circulation , vol.110 , pp. 1473-1476
    • Bauer, F.1    Eltchaninoff, H.2    Tron, C.3    Lesault, P.F.4    Agatiello, C.5    Nercolini, D.6
  • 12
    • 33644910414 scopus 로고    scopus 로고
    • Treatment of calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience
    • Cribier A., Eltchaninoff H., Tron C., Bauer F., Agatiello C., Nercolini D., et al. Treatment of calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience. J Am Coll Cardiol 47 (2006) 1214-1223
    • (2006) J Am Coll Cardiol , vol.47 , pp. 1214-1223
    • Cribier, A.1    Eltchaninoff, H.2    Tron, C.3    Bauer, F.4    Agatiello, C.5    Nercolini, D.6
  • 13
    • 10744220322 scopus 로고    scopus 로고
    • Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis
    • Cribier A., Eltchaninoff H., Tron C., Bauer F., Agatiello C., Sebagh L., et al. Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis. J Am Coll Cardiol 43 (2004) 698-703
    • (2004) J Am Coll Cardiol , vol.43 , pp. 698-703
    • Cribier, A.1    Eltchaninoff, H.2    Tron, C.3    Bauer, F.4    Agatiello, C.5    Sebagh, L.6
  • 14
    • 33749634251 scopus 로고    scopus 로고
    • Percutaneous implantation of the CoreValve self-expanding valve prosthesis in high-risk patients with aortic valve disease: the Siegburg first-in-man study
    • Grube E., Laborde J.C., Gerckens U., Felderhoff T., Sauren B., Buellesfeld L., et al. Percutaneous implantation of the CoreValve self-expanding valve prosthesis in high-risk patients with aortic valve disease: the Siegburg first-in-man study. Circulation 114 (2006) 1616-1624
    • (2006) Circulation , vol.114 , pp. 1616-1624
    • Grube, E.1    Laborde, J.C.2    Gerckens, U.3    Felderhoff, T.4    Sauren, B.5    Buellesfeld, L.6
  • 15
    • 34250815116 scopus 로고    scopus 로고
    • Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome
    • Grube E., Schuler G., Buellesfeld L., Gerckens U., Linke A., Wenaweser P., et al. Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome. J Am Coll Cardiol 50 (2007) 69-76
    • (2007) J Am Coll Cardiol , vol.50 , pp. 69-76
    • Grube, E.1    Schuler, G.2    Buellesfeld, L.3    Gerckens, U.4    Linke, A.5    Wenaweser, P.6
  • 16
    • 33746862304 scopus 로고    scopus 로고
    • Transapical transcatheter aortic valve implantation in humans: initial clinical experience
    • Lichtenstein S.V., Cheung A., Ye J., Thompson C.R., Carere R.G., Pasupati S., et al. Transapical transcatheter aortic valve implantation in humans: initial clinical experience. Circulation 114 (2006) 591-596
    • (2006) Circulation , vol.114 , pp. 591-596
    • Lichtenstein, S.V.1    Cheung, A.2    Ye, J.3    Thompson, C.R.4    Carere, R.G.5    Pasupati, S.6
  • 18
    • 34547919242 scopus 로고    scopus 로고
    • Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis
    • Webb J.G., Pasupati S., Humphries K., Thompson C., Altwegg L., Moss R., et al. Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis. Circulation 116 (2007) 755-763
    • (2007) Circulation , vol.116 , pp. 755-763
    • Webb, J.G.1    Pasupati, S.2    Humphries, K.3    Thompson, C.4    Altwegg, L.5    Moss, R.6
  • 19
  • 22
    • 2542490236 scopus 로고    scopus 로고
    • A mathematical model to predict the in vivo pulsatile drag forces acting on bifurcated stent grafts used in endovascular treatment of abdominal aortic aneurysms (AAA)
    • Morris L., Delassus P., Walsh M., and McGloughlin T. A mathematical model to predict the in vivo pulsatile drag forces acting on bifurcated stent grafts used in endovascular treatment of abdominal aortic aneurysms (AAA). J Biomech 37 (2004) 1087-1095
    • (2004) J Biomech , vol.37 , pp. 1087-1095
    • Morris, L.1    Delassus, P.2    Walsh, M.3    McGloughlin, T.4
  • 23
    • 33747138280 scopus 로고    scopus 로고
    • Analysis of biomechanical factors affecting stent-graft migration in an abdominal aortic aneurysm model
    • Li Z., and Kleinstreuer C. Analysis of biomechanical factors affecting stent-graft migration in an abdominal aortic aneurysm model. J Biomech 39 (2006) 2264-2273
    • (2006) J Biomech , vol.39 , pp. 2264-2273
    • Li, Z.1    Kleinstreuer, C.2
  • 25
    • 38349119223 scopus 로고    scopus 로고
    • Dynamic simulation of bioprosthetic heart valves using a stress resultant shell model
    • Kim H., Lu J., Sacks M.S., and Chandran K.B. Dynamic simulation of bioprosthetic heart valves using a stress resultant shell model. Ann Biomed Eng 36 (2008) 262-275
    • (2008) Ann Biomed Eng , vol.36 , pp. 262-275
    • Kim, H.1    Lu, J.2    Sacks, M.S.3    Chandran, K.B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.