State of art of fault current limiters and their impact on overcurrent protection

Author keywords

Fault current limiters; Operating time and co ordination; Overcurrent relays; Protection system

Indexed keywords

FAULT CURRENT LIMITER; FAULT CURRENTS; FCL DEVICES; INITIAL STAGES; NETWORK SPLITTING; OPERATING TIME; OVERCURRENT RELAYS; PROTECTION SYSTEMS; PSCAD/EMTDC; TRANSMISSION AND DISTRIBUTION;

EID: 71849108304     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PES.2009.5275284     Document Type: Conference Paper
Times cited : (11)

References (11)
  • 1
    • 52349101764 scopus 로고    scopus 로고
    • Utility Perspective of Fault Current Limiters and Expected Synergies from Integrating Fault Current Limiters with Superconducting Cables
    • P.M.Duggan, "Utility Perspective of Fault Current Limiters and Expected Synergies from Integrating Fault Current Limiters with Superconducting Cables," in Conf. Rec. 2008 IEEE Int. Conf Power and Energy Society General Meeting pp.1 .
    • Conf. Rec. 2008 IEEE Int. Conf Power and Energy Society General Meeting , pp. 1
    • Duggan, P.M.1
  • 2
    • 71849110639 scopus 로고    scopus 로고
    • Queensland Government, Department of Industrial Relations, Available
    • "High Fault Currents", Queensland Government, Department of Industrial Relations 2003. Available: http://www.deir.qld.gov.au/pdf/eso/ highfault-brochure2003.pdf
    • (2003) High Fault Currents
  • 3
    • 71849088731 scopus 로고    scopus 로고
    • CIGRE Working Group, Guideline of the impacts of Fault Current Limiting Devices on Protection Systems. CIGRE publishing, A3.16, February 2008. Standard FCL and Cigre
    • CIGRE Working Group, "Guideline of the impacts of Fault Current Limiting Devices on Protection Systems". CIGRE publishing, Vol A3.16, February 2008. Standard FCL and Cigre
  • 4
    • 71849106298 scopus 로고    scopus 로고
    • CIGRE Working Group, Fault Current Limiters in Electrical medium and high voltage systems. GIGRE publishing, A3.10, December 2003.
    • CIGRE Working Group, "Fault Current Limiters in Electrical medium and high voltage systems". GIGRE publishing, Vol A3.10, December 2003.
  • 7
    • 71849104807 scopus 로고    scopus 로고
    • Mason. C.R, The Art & Science of Protective Relaying, pp. Available: www.geindustrial.com/pm/notes/artsci/artsci.pdf
    • Mason. C.R, "The Art & Science of Protective Relaying," pp. Available: www.geindustrial.com/pm/notes/artsci/artsci.pdf
  • 8
    • 71849103599 scopus 로고    scopus 로고
    • J. Jager, Interaction Between Fault Current Limiters and Protection - A Glance at the Final Report of CIGRE WG- A3.16, in Conf. Power and Energy Society General Meeting pp.1-3.
    • J. Jager, "Interaction Between Fault Current Limiters and Protection - A Glance at the Final Report of CIGRE WG- A3.16," in Conf. Power and Energy Society General Meeting pp.1-3.