메뉴 건너뛰기




Volumn 55, Issue 1, 2010, Pages 83-97

The number of beams in IMRT - Theoretical investigations and implications for single-arc IMRT

Author keywords

[No Author keywords available]

Indexed keywords

ANALYTICAL EXPRESSIONS; AXIS OF ROTATION; BEAM ANGLE; BEAM PROFILES; CHEBYSHEV POLYNOMIALS; CONTINUOUS ROTATION; DEPTH DOSE; DOSE PROFILE; FAN OUT; FINITE DEGREE; INTENSITY-MODULATED RADIATION THERAPY; MAIN EFFECT; MAXIMUM DEGREE; SMOOTH FUNCTIONS; THEORETICAL INVESTIGATIONS; TREATMENT PLANNING; VOLUMETRIC MODULATED ARC THERAPY;

EID: 71849084000     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/55/1/006     Document Type: Article
Times cited : (47)

References (18)
  • 1
    • 0032969778 scopus 로고    scopus 로고
    • Fast and exact 2D image reconstruction by means of Chebyshev decomposition and backprojection
    • Bortfeld T and Oelfke U 1999 Fast and exact 2D image reconstruction by means of Chebyshev decomposition and backprojection Phys. Med. Biol. 44 1105-20
    • (1999) Phys. Med. Biol. , vol.44 , pp. 1105-1120
    • Bortfeld, T.1    Oelfke, U.2
  • 2
    • 0033711209 scopus 로고    scopus 로고
    • What is the optimum leaf width of a multileaf collimator?
    • Bortfeld T, Oelfke U and Nill S 2000 What is the optimum leaf width of a multileaf collimator? Med. Phys. 27 2494-502
    • (2000) Med. Phys. , vol.27 , pp. 2494-2502
    • Bortfeld, T.1    Oelfke, U.2    Nill, S.3
  • 5
    • 24644463683 scopus 로고    scopus 로고
    • Sweeping-window arc therapy: An implementation of rotational IMRT with automatic beam-weight calculation
    • Cameron C 2005 Sweeping-window arc therapy: an implementation of rotational IMRT with automatic beam-weight calculation Phys. Med. Biol. 50 4317-36
    • (2005) Phys. Med. Biol. , vol.50 , pp. 4317-4336
    • Cameron, C.1
  • 7
    • 0026661373 scopus 로고
    • The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimation
    • Convery D and Rosenbloom M 1992 The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimation Phys. Med. Biol. 37 1359-74
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1359-1374
    • Convery, D.1    Rosenbloom, M.2
  • 9
    • 0023513085 scopus 로고
    • A problem in rotation therapy with x-rays: Dose distributions with an axis of symmetry
    • Cormack A M and Cormack R A 1987 A problem in rotation therapy with x-rays: dose distributions with an axis of symmetry Int. J. Radiat. Oncol. Biol. Phys. 13 1921-5
    • (1987) Int. J. Radiat. Oncol. Biol. Phys. , vol.13 , pp. 1921-1925
    • Cormack, A.M.1    Cormack, R.A.2
  • 10
    • 84980225807 scopus 로고
    • On a problem in radiotherapy: Questions of non-negativity
    • Cormack A M and Quinto E T 1989 On a problem in radiotherapy: questions of non-negativity Int. J. Imaging Syst. Technol. 1 120-4
    • (1989) Int. J. Imaging Syst. Technol. , vol.1 , pp. 120-124
    • Cormack, A.M.1    Quinto, E.T.2
  • 14
    • 37549049393 scopus 로고    scopus 로고
    • Volumetric modulated arc therapy: IMRT in a single gantry arc
    • Otto K 2008 Volumetric modulated arc therapy: IMRT in a single gantry arc Med. Phys. 35 310-7
    • (2008) Med. Phys. , vol.35 , pp. 310-317
    • Otto, K.1
  • 16
    • 34547350663 scopus 로고    scopus 로고
    • Development of an optimization concept for arc-modulated cone beam therapy
    • Ulrich S, Nill S and Oelfke U 2007 Development of an optimization concept for arc-modulated cone beam therapy Phys. Med. Biol. 52 4099-119
    • (2007) Phys. Med. Biol. , vol.52 , pp. 4099-4119
    • Ulrich, S.1    Nill, S.2    Oelfke, U.3
  • 17
    • 51849101201 scopus 로고    scopus 로고
    • Arc-modulated radiation therapy (amrt): A single-arc form of intensity-modulated arc therapy
    • Wang C, Luan S, Tang G, Chen D Z, Earl M A and Yu C X 2008 Arc-modulated radiation therapy (amrt): a single-arc form of intensity-modulated arc therapy Phys. Med. Biol. 53 6291-303
    • (2008) Phys. Med. Biol. , vol.53 , pp. 6291-6303
    • Wang, C.1    Luan, S.2    Tang, G.3    Chen, D.Z.4    Earl, M.A.5    Yu, C.X.6
  • 18
    • 70349580089 scopus 로고    scopus 로고
    • Some considerations concerning volume-modulated arc therapy: A stepping stone towards a general theory
    • Webb S and McQuaid D 2009 Some considerations concerning volume-modulated arc therapy: a stepping stone towards a general theory Phys. Med. Biol. 54 4345-60
    • (2009) Phys. Med. Biol. , vol.54 , pp. 4345-4360
    • Webb, S.1    McQuaid, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.