메뉴 건너뛰기




Volumn 103, Issue 6, 2009, Pages 828-832

Respiratory impedance during weaning from mechanical ventilation in a mixed population of critically ill patients

Author keywords

Ventilation, high frequency oscillation; Ventilation, mechanical; Ventilation, respiratory impedance

Indexed keywords

AGED; AIRWAY PRESSURE; AIRWAY RESISTANCE; ARTICLE; ARTIFICIAL VENTILATION; BREATHING; CLINICAL ARTICLE; CONTROLLED STUDY; CRITICALLY ILL PATIENT; ENDOTRACHEAL TUBE; EXTUBATION; FEMALE; HUMAN; MALE; OSCILLATION; PRIORITY JOURNAL; RESPIRATORY AIRFLOW; TIDAL VOLUME;

EID: 71749121792     PISSN: 00070912     EISSN: 14716771     Source Type: Journal    
DOI: 10.1093/bja/aep301     Document Type: Article
Times cited : (12)

References (23)
  • 1
    • 34248173856 scopus 로고    scopus 로고
    • Weaning from mechanical ventilation
    • Boles JM, Bion J, Connors A, et al. Weaning from mechanical ventilation. Eur Respir J 2007; 29: 1033-56
    • (2007) Eur Respir J , vol.29 , pp. 1033-1056
    • Boles, J.M.1    Bion, J.2    Connors, A.3
  • 2
    • 0027937272 scopus 로고
    • Modes of mechanical ventilation and weaning. A national survey of Spanish hospitals
    • Esteban A, Alia I, Ibañez J, et al. Modes of mechanical ventilation and weaning. A national survey of Spanish hospitals. Chest 1994; 106: 1188-93
    • (1994) Chest , vol.106 , pp. 1188-1193
    • Esteban, A.1    Alia, I.2    Ibañez, J.3
  • 3
    • 0037116657 scopus 로고    scopus 로고
    • Characteristics and outcomes in adult patients receiving mechanical ventilation: A 28-day international study
    • Esteban A, Anzueto A, Frutos F, et al. Characteristics and outcomes in adult patients receiving mechanical ventilation: A 28-day international study. J Am Med Assoc 2002; 287: 345-55
    • (2002) J Am Med Assoc , vol.287 , pp. 345-355
    • Esteban, A.1    Anzueto, A.2    Frutos, F.3
  • 5
    • 0035963554 scopus 로고    scopus 로고
    • Advances in mechanical ventilation
    • Tobin MJ. Advances in mechanical ventilation. N Engl J Med 2001; 344: 1986-96
    • (2001) N Engl J Med , vol.344 , pp. 1986-1996
    • Tobin, M.J.1
  • 6
    • 0030950538 scopus 로고    scopus 로고
    • Pathophysiologic basis of acute respiratory distress in patients who fail a trial of weaning from mechanical ventilation
    • Jubran A, Tobin MJ. Pathophysiologic basis of acute respiratory distress in patients who fail a trial of weaning from mechanical ventilation. Am J Respir Crit Care Med 1997; 155: 906-15
    • (1997) Am J Respir Crit Care Med , vol.155 , pp. 906-915
    • Jubran, A.1    Tobin, M.J.2
  • 7
    • 33845934998 scopus 로고    scopus 로고
    • Use of N-terminal probrain natriuretic peptide to detect acute cardiac dysfunction during weaning failure in difficult-to-wean patients with chronic obstructive pulmonary disease
    • Grasso S, Leone A, De Michele M, et al. Use of N-terminal probrain natriuretic peptide to detect acute cardiac dysfunction during weaning failure in difficult-to-wean patients with chronic obstructive pulmonary disease. Crit Care Med 2007; 35: 96-105
    • (2007) Crit Care Med , vol.35 , pp. 96-105
    • Grasso, S.1    Leone, A.2    De Michele, M.3
  • 8
    • 0035153982 scopus 로고    scopus 로고
    • Forced oscillation assessment of respiratory mechanics in ventilated patients
    • Navajas D, Farre R. Forced oscillation assessment of respiratory mechanics in ventilated patients. Crit Care 2001; 5: 3-9
    • (2001) Crit Care , vol.5 , pp. 3-9
    • Navajas, D.1    Farre, R.2
  • 9
    • 0033389274 scopus 로고    scopus 로고
    • Oscillation mechanics
    • Milic-Emili J, ed. Wakefield: European Respiratory Society Journals
    • Navajas D, Farre R. Oscillation mechanics. In: Milic-Emili J, ed. Respiratory Mechanics. European Respiratory Monograph, Vol.4. Wakefield: European Respiratory Society Journals, 1999; 112-40
    • (1999) Respiratory Mechanics. European Respiratory Monograph , vol.4 , pp. 112-140
    • Navajas, D.1    Farre, R.2
  • 10
    • 33845504072 scopus 로고    scopus 로고
    • Noninvasive detection of expiratory flow limitation in COPD patients during nasal CPAP
    • Dellaca RL, Rotger M, Aliverti A, et al. Noninvasive detection of expiratory flow limitation in COPD patients during nasal CPAP. Eur Respir J 2006; 27: 983-91
    • (2006) Eur Respir J , vol.27 , pp. 983-991
    • Dellaca, R.L.1    Rotger, M.2    Aliverti, A.3
  • 11
    • 0035447004 scopus 로고    scopus 로고
    • Oscillatory resistance measured during noninvasive proportional assist ventilation
    • Farre R, Mancini M, Rotger M, et al. Oscillatory resistance measured during noninvasive proportional assist ventilation. Am J Respir Crit Care Med 2001; 164: 790-4
    • (2001) Am J Respir Crit Care Med , vol.164 , pp. 790-794
    • Farre, R.1    Mancini, M.2    Rotger, M.3
  • 12
    • 0029144308 scopus 로고
    • Servocontrolled generator to measure respiratory impedance from 0.25 to 26 Hz in ventilated patients at different PEEP levels
    • Farre R, Ferrer M, Rotger M, et al. Servocontrolled generator to measure respiratory impedance from 0.25 to 26 Hz in ventilated patients at different PEEP levels. Eur Respir J 1995; 8: 1222-7
    • (1995) Eur Respir J , vol.8 , pp. 1222-1227
    • Farre, R.1    Ferrer, M.2    Rotger, M.3
  • 13
    • 0024836258 scopus 로고
    • Respiratory input impedance during high frequency oscillatory ventilation
    • Navajas D, Farre R. Respiratory input impedance during high frequency oscillatory ventilation. Br J Anaesth 1989; 63: 85-90S
    • (1989) Br J Anaesth , vol.63
    • Navajas, D.1    Farre, R.2
  • 14
    • 0026764873 scopus 로고
    • Validation of a technique to assess maximal inspiratory pressure in poorly cooperative patients
    • Truwit JD, Marini JJ. Validation of a technique to assess maximal inspiratory pressure in poorly cooperative patients. Chest 1992; 102: 1216-9
    • (1992) Chest , vol.102 , pp. 1216-1219
    • Truwit, J.D.1    Marini, J.J.2
  • 15
    • 0027336888 scopus 로고
    • Respiratory mechanics studied by forced oscillations during artificial ventilation
    • Peslin R, Felicio DS, Duvivier C, et al. Respiratory mechanics studied by forced oscillations during artificial ventilation. Eur Respir J 1993; 6: 772-84
    • (1993) Eur Respir J , vol.6 , pp. 772-784
    • Peslin, R.1    Felicio, D.S.2    Duvivier, C.3
  • 16
    • 31944437927 scopus 로고    scopus 로고
    • Early noninvasive ventilation averts extubation failure in patients at risk: A randomized trial
    • Ferrer M, Valencia M, Nicolas JM, et al. Early noninvasive ventilation averts extubation failure in patients at risk: A randomized trial. Am J Respir Crit Care Med 2006; 173: 164-70
    • (2006) Am J Respir Crit Care Med , vol.173 , pp. 164-170
    • Ferrer, M.1    Valencia, M.2    Nicolas, J.M.3
  • 17
    • 0025896865 scopus 로고
    • A prospective study of indexes predicting the outcome of trials of weaning from mechanical ventilation
    • Yang KL, Tobin MJ. A prospective study of indexes predicting the outcome of trials of weaning from mechanical ventilation. N Engl J Med 1991; 324: 1445-50
    • (1991) N Engl J Med , vol.324 , pp. 1445-1450
    • Yang, K.L.1    Tobin, M.J.2
  • 18
    • 0033958133 scopus 로고    scopus 로고
    • Capnometric recirculation gas tonometry and weaning from mechanical ventilation
    • Maldonado A, Bauer TT, Ferrer M, et al. Capnometric recirculation gas tonometry and weaning from mechanical ventilation. Am J Respir Crit Care Med 2000; 161: 171-6
    • (2000) Am J Respir Crit Care Med , vol.161 , pp. 171-176
    • Maldonado, A.1    Bauer, T.T.2    Ferrer, M.3
  • 19
    • 0031203590 scopus 로고    scopus 로고
    • Passive mechanics of lung and chest wall in patients who failed or succeeded in trials of weaning
    • Jubran A, Tobin MJ. Passive mechanics of lung and chest wall in patients who failed or succeeded in trials of weaning. Am J Respir Crit Care Med 1997; 156: 669-70
    • (1997) Am J Respir Crit Care Med , vol.156 , pp. 669-670
    • Jubran, A.1    Tobin, M.J.2
  • 20
    • 0033980223 scopus 로고    scopus 로고
    • Non-invasive assessment of respiratory resistance in severe chronic respiratory patients with nasal CPAP
    • Farre R, Gavela E, Rotger M, et al. Non-invasive assessment of respiratory resistance in severe chronic respiratory patients with nasal CPAP. Eur Respir J 2000; 15: 314-9
    • (2000) Eur Respir J , vol.15 , pp. 314-319
    • Farre, R.1    Gavela, E.2    Rotger, M.3
  • 21
    • 0027946332 scopus 로고
    • Comparison of three methods of gradual withdrawal from ventilatory support during weaning from mechanical ventilation
    • Brochard L, Rauss A, Benito S, et al. Comparison of three methods of gradual withdrawal from ventilatory support during weaning from mechanical ventilation. Am J Respir Crit Care Med 1994; 150: 896-903
    • (1994) Am J Respir Crit Care Med , vol.150 , pp. 896-903
    • Brochard, L.1    Rauss, A.2    Benito, S.3
  • 23
    • 70349427011 scopus 로고    scopus 로고
    • Non-invasive ventilation after extubation in hypercapnic patients with chronic respiratory disorders: Randomised controlled trial
    • Ferrer M, Sellares J, Valencia M, et al. Non-invasive ventilation after extubation in hypercapnic patients with chronic respiratory disorders: Randomised controlled trial. Lancet 2009; 374: 1082-8
    • (2009) Lancet , vol.374 , pp. 1082-1088
    • Ferrer, M.1    Sellares, J.2    Valencia, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.