Volumn 156, Issue 1, 2009, Pages 14-21

Analysis of in vitro and in vivo bidirectional flow velocities by phase-resolved Doppler Fourier-domain OCT

Author keywords

Blood flow; In vitro; In vivo; Phase resolved Doppler optical coherence tomography

Indexed keywords

BI-DIRECTIONAL FLOWS; BLOOD FLOW; BLOOD FLOW VELOCITY; DOPPLER; DOPPLER FD-OCT; DOPPLER OPTICAL COHERENCE TOMOGRAPHY; FLOW PHANTOM; FLOW PROFILE; FOURIER-DOMAIN OCT; FOURIER-DOMAIN OPTICAL COHERENCE TOMOGRAPHY; GLASS CAPILLARIES; HUMAN BLOODS; IN-VITRO; IN-VIVO; INNER DIAMETERS; INTRALIPIDS; LARGE DIAMETER; MEASURED DATA; MOUSE MODELS; NON-INVASIVE IMAGING; PARABOLIC VELOCITY PROFILE; RETINAL VESSELS; STRUCTURAL IMAGING; VELOCITY PROFILES; WHOLE BLOOD;

EID: 71749121025     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2009.02.025     Document Type: Article
Times cited : (19)

References (32)
  • 2
    • 2942703878 scopus 로고    scopus 로고
    • Sensitivity advantage of swept source and Fourier domain optical coherence tomography
    • Choma M., Sarunic M., Yang C., and Izatt J. Sensitivity advantage of swept source and Fourier domain optical coherence tomography. Opt. Express 11 (2003) 2183-2189
    • (2003) Opt. Express , vol.11 , pp. 2183-2189
    • Choma, M.1    Sarunic, M.2    Yang, C.3    Izatt, J.4
  • 3
    • 0242301675 scopus 로고    scopus 로고
    • Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography
    • de Boer J.F., Cense B., Park B.H., Pierce M.C., Tearney G.J., and Bouma B.E. Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography. Opt. Lett. 28 (2003) 2067-2069
    • (2003) Opt. Lett. , vol.28 , pp. 2067-2069
    • de Boer, J.F.1    Cense, B.2    Park, B.H.3    Pierce, M.C.4    Tearney, G.J.5    Bouma, B.E.6
  • 4
    • 0038618462 scopus 로고    scopus 로고
    • Performance of Fourier domain vs. time domain optical coherence tomography
    • Leitgeb R., Hitzenberger C., and Fercher A. Performance of Fourier domain vs. time domain optical coherence tomography. Opt. Express 11 (2003) 889-894
    • (2003) Opt. Express , vol.11 , pp. 889-894
    • Leitgeb, R.1    Hitzenberger, C.2    Fercher, A.3
  • 5
    • 2942715001 scopus 로고    scopus 로고
    • High-speed spectral-domain optical coherence tomography at 1.3 μm wavelength
    • Yun S.H., Tearney G.J., Bouma B.E., Park B., and de Boer J.F. High-speed spectral-domain optical coherence tomography at 1.3 μm wavelength. Opt. Express 11 (2003) 3598-3604
    • (2003) Opt. Express , vol.11 , pp. 3598-3604
    • Yun, S.H.1    Tearney, G.J.2    Bouma, B.E.3    Park, B.4    de Boer, J.F.5
  • 7
    • 2942733251 scopus 로고    scopus 로고
    • In vivo dynamic human retinal blood flow imaging using ultra-high-speed spectral domain optical coherence tomography
    • White B., Pierce M., Nassif N., Cense B., Park B., Tearney G., Bouma B., Chen T., and de Boer J. In vivo dynamic human retinal blood flow imaging using ultra-high-speed spectral domain optical coherence tomography. Opt. Express 11 (2003) 3490-3497
    • (2003) Opt. Express , vol.11 , pp. 3490-3497
    • White, B.1    Pierce, M.2    Nassif, N.3    Cense, B.4    Park, B.5    Tearney, G.6    Bouma, B.7    Chen, T.8    de Boer, J.9
  • 8
    • 2942703836 scopus 로고    scopus 로고
    • Real-time assessment of retinal blood flow with ultrafast acquisition by color Doppler Fourier domain optical coherence tomography
    • Leitgeb R., Schmetterer L., Drexler W., Fercher A., Zawadzki R., and Bajraszewski T. Real-time assessment of retinal blood flow with ultrafast acquisition by color Doppler Fourier domain optical coherence tomography. Opt. Express 11 (2003) 3116-3121
    • (2003) Opt. Express , vol.11 , pp. 3116-3121
    • Leitgeb, R.1    Schmetterer, L.2    Drexler, W.3    Fercher, A.4    Zawadzki, R.5    Bajraszewski, T.6
  • 9
    • 36248972318 scopus 로고    scopus 로고
    • Automatic retinal blood flow calculation using spectral domain optical coherence tomography
    • Wehbe H., Ruggeri M., Jiao S., Gregori G., Puliafito C.A., and Zhao W. Automatic retinal blood flow calculation using spectral domain optical coherence tomography. Opt. Express 15 (2007) 15193-15206
    • (2007) Opt. Express , vol.15 , pp. 15193-15206
    • Wehbe, H.1    Ruggeri, M.2    Jiao, S.3    Gregori, G.4    Puliafito, C.A.5    Zhao, W.6
  • 12
    • 25144461753 scopus 로고    scopus 로고
    • In vivo blood flow imaging by a swept laser source based Fourier domain optical Doppler tomography
    • Zhang J., and Chen Z. In vivo blood flow imaging by a swept laser source based Fourier domain optical Doppler tomography. Opt. Express 13 (2005) 7449-7457
    • (2005) Opt. Express , vol.13 , pp. 7449-7457
    • Zhang, J.1    Chen, Z.2
  • 13
    • 0042810881 scopus 로고    scopus 로고
    • Determination of flow velocity vector based on Doppler shift and spectrum broadening with optical coherence tomography
    • 13 S.G., Proskurin Y., He R.K., and Wang. Determination of flow velocity vector based on Doppler shift and spectrum broadening with optical coherence tomography. Opt. Lett. 28 (2003) 1227-1229
    • (2003) Opt. Lett. , vol.28 , pp. 1227-1229
    • 13, S.G.1    Proskurin, Y.2    He, R.K.3    Wang4
  • 14
    • 0000204268 scopus 로고    scopus 로고
    • Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity
    • Zhao Y., Chen Z., Saxer C., Xiang S., de Boer J.F., and Nelson J.S. Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity. Opt. Lett. 25 (2000) 114-116
    • (2000) Opt. Lett. , vol.25 , pp. 114-116
    • Zhao, Y.1    Chen, Z.2    Saxer, C.3    Xiang, S.4    de Boer, J.F.5    Nelson, J.S.6
  • 15
    • 4644298765 scopus 로고    scopus 로고
    • Motion artifacts in optical coherence tomography with frequency-domain ranging
    • Yun S.H., Tearney G.J., de Boer J.F., and Bouma B.E. Motion artifacts in optical coherence tomography with frequency-domain ranging. Opt. Express 12 (2004) 2977-2998
    • (2004) Opt. Express , vol.12 , pp. 2977-2998
    • Yun, S.H.1    Tearney, G.J.2    de Boer, J.F.3    Bouma, B.E.4
  • 16
    • 33846519303 scopus 로고    scopus 로고
    • Resonant Doppler flow imaging and optical vivisection of retinal blood vessels
    • Bachmann A.H., Villiger M.L., Blatter C., Lasser T., and Leitgeb R.A. Resonant Doppler flow imaging and optical vivisection of retinal blood vessels. Opt. Express 15 (2007) 408-422
    • (2007) Opt. Express , vol.15 , pp. 408-422
    • Bachmann, A.H.1    Villiger, M.L.2    Blatter, C.3    Lasser, T.4    Leitgeb, R.A.5
  • 17
    • 43049093773 scopus 로고    scopus 로고
    • Flow velocity estimation using joint spectral and time domain optical coherence tomography
    • Szkulmowski M., Szkulmowska A., Bajraszewski T., Kowalczyk A., and Wojtkowski M. Flow velocity estimation using joint spectral and time domain optical coherence tomography. Opt. Express 16 (2008) 6008-6025
    • (2008) Opt. Express , vol.16 , pp. 6008-6025
    • Szkulmowski, M.1    Szkulmowska, A.2    Bajraszewski, T.3    Kowalczyk, A.4    Wojtkowski, M.5
  • 20
    • 0038157635 scopus 로고    scopus 로고
    • Influence of the refractive index-mismatch at the boundaries measured in fluorescence enhanced frequency-domain photon migration imaging
    • Godavarty A., Hawrysz D., Roy R., Sevick-Muraca E., and Eppstein M. Influence of the refractive index-mismatch at the boundaries measured in fluorescence enhanced frequency-domain photon migration imaging. Opt. Express 10 (2002) 653-662
    • (2002) Opt. Express , vol.10 , pp. 653-662
    • Godavarty, A.1    Hawrysz, D.2    Roy, R.3    Sevick-Muraca, E.4    Eppstein, M.5
  • 21
    • 5644288819 scopus 로고    scopus 로고
    • Monitoring of glycated hemoglobin by OCT measurement of refractive index
    • Tuchin V.V., Wang R.K., Galanzha E.I., Elder J.B., and Zhestkov D.M. Monitoring of glycated hemoglobin by OCT measurement of refractive index. Proc. SPIE 5316 (2004) 66-77
    • (2004) Proc. SPIE , vol.5316 , pp. 66-77
    • Tuchin, V.V.1    Wang, R.K.2    Galanzha, E.I.3    Elder, J.B.4    Zhestkov, D.M.5
  • 23
    • 0036017339 scopus 로고    scopus 로고
    • Dynamic optical coherence tomography in studies of optical clearing, sedimentation, and aggregation of immersed blood
    • Tuchin V.V., Xu X., and Wang R.K. Dynamic optical coherence tomography in studies of optical clearing, sedimentation, and aggregation of immersed blood. Appl. Opt. 41 (2002) 258-271
    • (2002) Appl. Opt. , vol.41 , pp. 258-271
    • Tuchin, V.V.1    Xu, X.2    Wang, R.K.3
  • 25
    • 23044461501 scopus 로고    scopus 로고
    • The effect of multiple scattering on velocity profiles measured using Doppler OCT
    • Moger J., Matcher S.J., Winlove C.P., and Shore A. The effect of multiple scattering on velocity profiles measured using Doppler OCT. J. Phys. D: Appl. Phys. 38 (2005) 2597-2605
    • (2005) J. Phys. D: Appl. Phys. , vol.38 , pp. 2597-2605
    • Moger, J.1    Matcher, S.J.2    Winlove, C.P.3    Shore, A.4
  • 26
    • 34250405335 scopus 로고
    • Ein neues Rohrrheometer zur Realisierung hoher Schergeschwindigkeiten
    • Chmiel H. Ein neues Rohrrheometer zur Realisierung hoher Schergeschwindigkeiten. Rheol. Acta 14 (1972) 246-251
    • (1972) Rheol. Acta , vol.14 , pp. 246-251
    • Chmiel, H.1
  • 27
    • 0022869493 scopus 로고
    • Velocity profiles of blood platelets and red blood cells flowing in the arterioles of the rabbit mesentery
    • Tangelder G.J., Slaaf D.W., Muijtjens A.M., Arts T., oude Egbrink M.G., and Reneman R.S. Velocity profiles of blood platelets and red blood cells flowing in the arterioles of the rabbit mesentery. Circ. Res. 59 (1986) 505-514
    • (1986) Circ. Res. , vol.59 , pp. 505-514
    • Tangelder, G.J.1    Slaaf, D.W.2    Muijtjens, A.M.3    Arts, T.4    oude Egbrink, M.G.5    Reneman, R.S.6
  • 29
    • 33947621655 scopus 로고    scopus 로고
    • Mesoscale simulation of blood flow in small vessels
    • Bagchi P. Mesoscale simulation of blood flow in small vessels. Biophys. J. 92 (2007) 1858-1877
    • (2007) Biophys. J. , vol.92 , pp. 1858-1877
    • Bagchi, P.1
  • 31
    • 59049096490 scopus 로고    scopus 로고
    • Effects of axial, transverse and oblique sample motion in FD OCT in systems with global or rolling shutter line detector
    • Walther J., Krueger A., Cuevas M., and Koch E. Effects of axial, transverse and oblique sample motion in FD OCT in systems with global or rolling shutter line detector. J. Opt. Soc. Am. A 25 (2008) 2791-2802
    • (2008) J. Opt. Soc. Am. A , vol.25 , pp. 2791-2802
    • Walther, J.1    Krueger, A.2    Cuevas, M.3    Koch, E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.