메뉴 건너뛰기




Volumn 28, Issue 6, 2009, Pages 367-369

Spinal migration of a Kirschner wire after surgery for clavicular nonunion. A case report and review of the literature;Migration intrarachidienne d'une broche de Kirschner après une cure de pseudarthrose de la clavicule. Cas clinique et revue de la littérature

Author keywords

K wire migration; Nonunion clavicle; Spinal cord injury

Indexed keywords

ADULT; ARTICLE; CASE REPORT; CLAVICLE FRACTURE; CLINICAL EXAMINATION; ENDOPROSTHESIS LOOSENING; HUMAN; KIRSCHNER WIRE; LAMINECTOMY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; SHOULDER RADIOGRAPHY; SPINAL CORD;

EID: 71649114138     PISSN: 12973203     EISSN: 17696666     Source Type: Journal    
DOI: 10.1016/j.main.2009.08.007     Document Type: Article
Times cited : (24)

References (10)
  • 1
    • 0001056992 scopus 로고
    • Migration of a Kirschner wire from the shoulder region into the lung: report of two cases
    • Mazet R. Migration of a Kirschner wire from the shoulder region into the lung: report of two cases. J Bone Joint Surg Am 25 (1943) 477-483
    • (1943) J Bone Joint Surg Am , vol.25 , pp. 477-483
    • Mazet, R.1
  • 2
    • 34547442492 scopus 로고    scopus 로고
    • Migration of a Kirschner wire used in the fixation of a subcapital humeral fracture, causing cardiac tamponade. Case report and review of literature
    • Freund E., Nachman R., Gips H., and Hiss J. Migration of a Kirschner wire used in the fixation of a subcapital humeral fracture, causing cardiac tamponade. Case report and review of literature. Am J Forensic Med Pathol 28 (2007) 155-156
    • (2007) Am J Forensic Med Pathol , vol.28 , pp. 155-156
    • Freund, E.1    Nachman, R.2    Gips, H.3    Hiss, J.4
  • 3
    • 0025484793 scopus 로고
    • Migration of pins use in operation on the shoulder
    • Lyons F.A., and Rockwood Jr. C.A. Migration of pins use in operation on the shoulder. J Bone Joint Surg 72 (1990) 1262-1267
    • (1990) J Bone Joint Surg , vol.72 , pp. 1262-1267
    • Lyons, F.A.1    Rockwood Jr., C.A.2
  • 4
    • 0036226472 scopus 로고    scopus 로고
    • Intrathoracic migration of a Kirschner wire
    • Kumar P., Godbole R., Rees G.M., and Sarkar P. Intrathoracic migration of a Kirschner wire. J R Soc Med 95 (2002) 198-199
    • (2002) J R Soc Med , vol.95 , pp. 198-199
    • Kumar, P.1    Godbole, R.2    Rees, G.M.3    Sarkar, P.4
  • 5
    • 0018097708 scopus 로고
    • Complications due to migration of a Kirschner wire from the clavicle
    • Grauthoff H., and Klammer H.L. Complications due to migration of a Kirschner wire from the clavicle. Rofo 128 5 (1978) 591-594
    • (1978) Rofo , vol.128 , Issue.5 , pp. 591-594
    • Grauthoff, H.1    Klammer, H.L.2
  • 6
    • 0036941024 scopus 로고    scopus 로고
    • Intraspinal migration of a Kirschner wire 3-months after clavicular fracture fixation
    • Regel J.P., Pospiech J., Aalders T.A., and Ruchholtz S. Intraspinal migration of a Kirschner wire 3-months after clavicular fracture fixation. Neurosurg Rev 25 1-2 (2002) 110-112
    • (2002) Neurosurg Rev , vol.25 , Issue.1-2 , pp. 110-112
    • Regel, J.P.1    Pospiech, J.2    Aalders, T.A.3    Ruchholtz, S.4
  • 7
    • 34447276919 scopus 로고    scopus 로고
    • Kirschner wire migration causing spinal cord injury one year after internal fixation of a clavicle fracture
    • Fransen P., Bourgeois S., and Rommens J. Kirschner wire migration causing spinal cord injury one year after internal fixation of a clavicle fracture. Acta Orthop Belg 73 3 (2007) 390-392
    • (2007) Acta Orthop Belg , vol.73 , Issue.3 , pp. 390-392
    • Fransen, P.1    Bourgeois, S.2    Rommens, J.3
  • 8
    • 0031737484 scopus 로고    scopus 로고
    • Brown-Sequard syndrome caused by a Kirschner wire as a complication of clavicular osteosynthesis
    • Loncán L.I., Sempere D.F., and Ajuria J.E. Brown-Sequard syndrome caused by a Kirschner wire as a complication of clavicular osteosynthesis. Spinal Cord 36 11 (1998) 797-799
    • (1998) Spinal Cord , vol.36 , Issue.11 , pp. 797-799
    • Loncán, L.I.1    Sempere, D.F.2    Ajuria, J.E.3
  • 9
    • 27744606297 scopus 로고    scopus 로고
    • A spinal cord injury caused by a migrating Kirschner wire following osteosynthesis of the clavicle: a case review
    • Pribán V., and Toufar P. A spinal cord injury caused by a migrating Kirschner wire following osteosynthesis of the clavicle: a case review. Rozhl Chir 84 7 (2005) 373-375
    • (2005) Rozhl Chir , vol.84 , Issue.7 , pp. 373-375
    • Pribán, V.1    Toufar, P.2
  • 10
    • 28744441612 scopus 로고    scopus 로고
    • Kirschner wire migration in the contralateral lung after osteosynthesis of a clavicular fracture
    • Hegemann S., Kleining R., Schindler H.G., and Holthusen H. Kirschner wire migration in the contralateral lung after osteosynthesis of a clavicular fracture. Unfallchirurg 108 11 (2005) 991-993
    • (2005) Unfallchirurg , vol.108 , Issue.11 , pp. 991-993
    • Hegemann, S.1    Kleining, R.2    Schindler, H.G.3    Holthusen, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.