메뉴 건너뛰기




Volumn 7259, Issue , 2009, Pages

Model driven quantification of left ventricular function from sparse single-beat 3D echocardiography

Author keywords

3D Ultrasound; Cardiovascular; Left ventricle quantification; Segmentation

Indexed keywords

3-D ULTRASOUND; 3D ACTIVE SHAPE MODELS; 3D ECHOCARDIOGRAPHY; 3D MODELS; APPEARANCE MODELS; AVERAGE VOLUME; CARDIAC ANATOMY; CARDIAC CYCLES; CARDIAC PATHOLOGIES; CORRESPONDENCE PROBLEMS; CROSS SECTION; CROSS VALIDATION; DATA SPARSITY; ERROR MEASUREMENTS; INITIAL POSITION; LEAVE-ONE-OUT; LEFT VENTRICLES; LEFT VENTRICULAR; LEFT VENTRICULAR FUNCTION; MODEL INITIALIZATION; MODEL UPDATES; MODEL-BASED SEGMENTATION; MODEL-DRIVEN; PRIOR KNOWLEDGE; SPARSE SET;

EID: 71649112447     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.812490     Document Type: Conference Paper
Times cited : (3)

References (11)
  • 1
    • 0034209777 scopus 로고    scopus 로고
    • A fast rotating scanning unit for real-time three-dimensional echo data acquisition
    • Djoa, K.K. et al., "A fast rotating scanning unit for real-time three-dimensional echo data acquisition", Ultrasound Med. Biol. 26(5), 863-869 (2000).
    • (2000) Ultrasound Med. Biol , vol.26 , Issue.5 , pp. 863-869
    • Djoa, K.K.1
  • 2
    • 33845679984 scopus 로고    scopus 로고
    • Quantitative harmonic 3D echocardiography with a fast-rotating ultrasound transducer
    • Voormolen, M.M. et al., "Quantitative harmonic 3D echocardiography with a fast-rotating ultrasound transducer", IEEE Trans Ultrason Ferroelectr Freq Control, 53(10), 1739-1747 (2006).
    • (2006) IEEE Trans Ultrason Ferroelectr Freq Control , vol.53 , Issue.10 , pp. 1739-1747
    • Voormolen, M.M.1
  • 3
    • 0032073580 scopus 로고    scopus 로고
    • Endocardial border identification in two-dimensional echocardiographic images: Review of methods
    • Hammoude, A., "Endocardial border identification in two-dimensional echocardiographic images: review of methods", Computerized Medical Imaging and Graphics, 22(3), 181-193 (1998).
    • (1998) Computerized Medical Imaging and Graphics , vol.22 , Issue.3 , pp. 181-193
    • Hammoude, A.1
  • 4
    • 33746885878 scopus 로고    scopus 로고
    • Ultrasound image segmentation: A survey
    • Noble, A.J., Boukerroui, D., "Ultrasound image segmentation: A survey", IEEE Trans. Med. Imag., 25(8), 987-1010 (2006).
    • (2006) IEEE Trans. Med. Imag , vol.25 , Issue.8 , pp. 987-1010
    • Noble, A.J.1    Boukerroui, D.2
  • 6
    • 0037290219 scopus 로고    scopus 로고
    • Anisotropic filtering for model-based segmentation of 4-D cylindrical echocardiographic images
    • Pattern Reconit. Lett. 24
    • Montagnat J. et al., "Anisotropic filtering for model-based segmentation of 4-D cylindrical echocardiographic images", Pattern Reconit. Lett. 24, no. 4-5, pp. 815-828 (2003).
    • (2003) , Issue.4-5 , pp. 815-828
    • Montagnat, J.1
  • 7
    • 33745365108 scopus 로고    scopus 로고
    • Novel spatiotemporal voxel interpolation with multibeat fusion for 3D echocardiography with irregular data distribution
    • Bosch, J.G. et al., "Novel spatiotemporal voxel interpolation with multibeat fusion for 3D echocardiography with irregular data distribution", Proc. SPIE Medical Imaging 6147, 61470Q (2006).
    • (2006) Proc. SPIE Medical Imaging , vol.6147
    • Bosch, J.G.1
  • 8
    • 23844442599 scopus 로고    scopus 로고
    • Semi-automatic border detection method for left ventricular volume estimation in 4D ultrasound data
    • van Stralen, et al., "Semi-automatic border detection method for left ventricular volume estimation in 4D ultrasound data", Proc. SPIE Medical Imaging 5747, 1457-1467 (2005).
    • (2005) Proc. SPIE Medical Imaging , vol.5747 , pp. 1457-1467
    • van Stralen1
  • 9
    • 34948818246 scopus 로고    scopus 로고
    • Constrained active appearance models for segmentation of triplane echocardiograms
    • Hansegard, J., Urheim, S., Lunde, K., Rabben, S.I., "Constrained active appearance models for segmentation of triplane echocardiograms", IEEE Trans. Med. Imag., 26(10), 1391-1400 (2007).
    • (2007) IEEE Trans. Med. Imag , vol.26 , Issue.10 , pp. 1391-1400
    • Hansegard, J.1    Urheim, S.2    Lunde, K.3    Rabben, S.I.4
  • 10
    • 31744451421 scopus 로고    scopus 로고
    • SPASM: A 3D-ASM for segmentation of sparse and arbitrarily oriented cardiac MRI data
    • van Assen, H.C. et al., "SPASM: a 3D-ASM for segmentation of sparse and arbitrarily oriented cardiac MRI data", Medical Image Analysis, 10(2), 286-303 (2006).
    • (2006) Medical Image Analysis , vol.10 , Issue.2 , pp. 286-303
    • van Assen, H.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.